A secondary ion microprobe ion trap mass spectrometer

被引:5
|
作者
Todd, PJ [1 ]
Schaaff, TG [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1016/S1044-0305(02)00434-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ion trap mass analyzer has been attached to an organic secondary ion microprobe. A pressure differential >100 can be maintained between the ion trap and microprobe. The well-focused secondary ion beam can transit a small (2 mm) diameter tube, but gas flow from ion trap to microprobe is impeded. This pressure differential allows the microprobe to retain imaging capability. Ion trap and microprobe data systems are integrated by taking advantage of the highly reproducible periodicity of the ion trap operating in resonant ejection mode and asynchronous signal and data acquisition afforded by commercially available interface cards. Secondary ion mass spectra and images obtained indicate an approximately 10-fold improvement in sensitivity, although preliminary evidence indicates low (<1%) trapping efficiency. Image data acquisition using the ion trap for mass analysis requires at least 10 times as much time compared to using a quadrupole mass filter because the mass-selected instability mode is used for mass analysis, i.e., mass resolution in the ion trap is not continuous as it is in the quadrupole. (J Am Soc Mass Spectrom 2002, 13, 1099-1107) (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:1099 / 1107
页数:9
相关论文
共 50 条
  • [1] A secondary ion microprobe ion trap mass spectrometer
    Todd, Peter J.
    Schaaff, T.Gregory
    1600, Elsevier Inc. (13):
  • [2] Halo ion trap mass spectrometer
    Austin, Daniel E.
    Wang, Miao
    Tolley, Samuel E.
    Maas, Jeffrey D.
    Hawkins, Aaron R.
    Rockwood, Alan L.
    Tolley, H. Dennis
    Lee, Edgar D.
    Lee, Milton L.
    ANALYTICAL CHEMISTRY, 2007, 79 (07) : 2927 - 2932
  • [3] Sodium ion attachment reactions in an ion trap mass spectrometer
    Faye, T
    Brunot, A
    Sablier, M
    Tabet, JC
    Fujii, T
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (12) : 1066 - 1073
  • [4] ION AND LASER OPTICS WITH AN ION TRAP MASS-SPECTROMETER
    HEMBERGER, PH
    NOGAR, NS
    WILLIAMS, J
    SYKA, JEP
    CAMERON, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 110 - ANYL
  • [5] ION MICROPROBE MASS SPECTROMETER IN ALUMINUM ALLOY RESEARCH
    WESTERMAN, EJ
    JOURNAL OF METALS, 1970, 22 (12): : 28 - +
  • [6] VACUUM SYSTEM OF ION-MICROPROBE MASS SPECTROMETER
    BARRINGT.AE
    HERZOG, RFK
    POSCHENR.WP
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1966, 3 (05): : 239 - &
  • [7] Control system for an ion trap mass spectrometer
    Hopkins, Derek
    Alexander, Michael
    Swanson, Kenneth
    Buschbach, Michael
    Scientific Computing and Instrumentation, 2004, 21 (05): : 18 - 20
  • [8] Linear ion trap/Orbitrap mass spectrometer
    Erickson, B
    ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2089 - 2089
  • [9] A new linear ion trap mass spectrometer
    Hager, JW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) : 512 - 526
  • [10] A hyperboloid mass spectrometer with a monopolar ion trap
    E. V. Mamontov
    D. A. Ivlev
    Instruments and Experimental Techniques, 2000, 43 : 635 - 639