A secondary ion microprobe ion trap mass spectrometer

被引:5
作者
Todd, PJ [1 ]
Schaaff, TG [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1016/S1044-0305(02)00434-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ion trap mass analyzer has been attached to an organic secondary ion microprobe. A pressure differential >100 can be maintained between the ion trap and microprobe. The well-focused secondary ion beam can transit a small (2 mm) diameter tube, but gas flow from ion trap to microprobe is impeded. This pressure differential allows the microprobe to retain imaging capability. Ion trap and microprobe data systems are integrated by taking advantage of the highly reproducible periodicity of the ion trap operating in resonant ejection mode and asynchronous signal and data acquisition afforded by commercially available interface cards. Secondary ion mass spectra and images obtained indicate an approximately 10-fold improvement in sensitivity, although preliminary evidence indicates low (<1%) trapping efficiency. Image data acquisition using the ion trap for mass analysis requires at least 10 times as much time compared to using a quadrupole mass filter because the mass-selected instability mode is used for mass analysis, i.e., mass resolution in the ion trap is not continuous as it is in the quadrupole. (J Am Soc Mass Spectrom 2002, 13, 1099-1107) (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:1099 / 1107
页数:9
相关论文
共 22 条
[1]   EMPIRICAL-METHODS FOR DETERMINATION OF IONIZATION GAUGE RELATIVE SENSITIVITIES FOR DIFFERENT GASES [J].
BARTMESS, JE ;
GEORGIADIS, RM .
VACUUM, 1983, 33 (03) :149-153
[2]   OBSERVATION ON SURFACE-REACTIONS WITH STATIC METHOD OF SECONDARY ION MASS-SPECTROMETRY .1. METHOD [J].
BENNINGHOVEN, A .
SURFACE SCIENCE, 1971, 28 (02) :541-+
[3]  
BENNINGHOVEN A, 1987, SECONDARY ION MASS S, P664
[4]   APPLICATIONS OF SECONDARY ION MASS-SPECTROMETRY (SIMS) IN BIOLOGICAL-RESEARCH - A REVIEW [J].
BURNS, MS .
JOURNAL OF MICROSCOPY-OXFORD, 1982, 127 (SEP) :237-258
[5]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[6]   SAMPLE PREPARATION OF ANIMAL-TISSUES AND CELL-CULTURES FOR SECONDARY ION MASS-SPECTROMETRY (SIMS) MICROSCOPY [J].
CHANDRA, S ;
MORRISON, GH .
BIOLOGY OF THE CELL, 1992, 74 (01) :31-42
[7]  
DAWSON PH, 1976, QUADRUPOLE MASS SPEC, P105
[8]   A WIDE-ANGLE SECONDARY ION PROBE FOR ORGANIC ION IMAGING [J].
GRIMM, CC ;
SHORT, RT ;
TODD, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (05) :362-371
[9]   Detection limit and surface coverage determination for tributyl phosphate on soils by static SIMS [J].
Ingram, JC ;
Groenewold, GS ;
Appelhans, AD ;
Dahl, DA ;
Delmore, JE .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1309-1316
[10]  
LIEBL HUS, 1965, Patent No. 3517191