A demonstration scaling-up of the dissolved air flotation

被引:26
作者
Chung, Y [1 ]
Choi, YC [1 ]
Choi, YH [1 ]
Kang, HS [1 ]
机构
[1] Yonsei Univ, Inst Environm Res, Seo Dae Mun Ku, Seoul 120752, South Korea
关键词
drinking water treatment; dissolved air flotation; scale-up; full-scale plant;
D O I
10.1016/S0043-1354(99)00224-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dissolved air flotation (DAF) is currently being received in much attention as an effective process for solid-liquid separation in water technology. In this study, we scaled-up the DAF plant from a pilot-scale (72 m(3)/day) to a full-scale (6000 m(3)/day) plant and the sand-float type DAF was used. The concept of maintaining equal surface loading rate into scaling-up of DAF was a proper practice and strategy. In order to optimize the DAF plant, it was needed to determine the surface loading rare and air dissolving tube pressure. The optimum conditions of surface loading rate and air dissolving tube pressure were indicated in 7.5 m(3)/m(2) day and 440 kPa from the pilot plant, respectively. The removal efficiency for TOC and UV254 from the full-scale plant was as satisfactory as those from the pilot plant for the same surface loading rates. However, especially in flotation zone, the full-scale plant performed a little bit poorer than the pilot-scale plant in turbidity and chlorophyll-a reduction: because hull-scale plant had long retention time and turbulent mixing condition during backwashing time which might be brought about the breakage of fragile flocs. Performance comparisons between the full-scale DAF plant and the conventional plant located at the city of Nam-Yang Ju in Korea are presented. DAF process showed higher efficiency than the conventional settling system improving the water quality in general, namely, turbidity, TOC, UV254, Fe and Mn. We, therefore, conclude that DAF system should have substantial advantages over the conventional settling process in drinking water treatment. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:817 / 824
页数:8
相关论文
共 11 条
[1]   BUBBLE-SIZE IN FLOTATION THICKENING [J].
DERIJK, SE ;
VANDERGRAAF, JHJM ;
DENBLANKEN, JG .
WATER RESEARCH, 1994, 28 (02) :465-473
[2]   ALGAE, BUBBLES, COAGULANTS, AND DISSOLVED AIR FLOTATION [J].
EDZWALD, JK .
WATER SCIENCE AND TECHNOLOGY, 1993, 27 (10) :67-81
[3]  
Edzwald JK., 1992, DISSOLVED AIR FLOTAT
[4]   COMPARISON OF DISSOLVED AIR FLOTATION AND DIRECT-FILTRATION [J].
FERGUSON, C ;
LOGSDON, GS ;
CURLEY, D .
WATER SCIENCE AND TECHNOLOGY, 1995, 31 (3-4) :113-124
[5]  
GEORGE CY, 1996, ENV TECH NOV
[6]  
HART FL, 1978, ASCE J ENV ENG DIV, V104, P785
[7]  
JANSSENS JG, 1991, DVGW SCHRIFTENREIHE, V67, P229
[8]  
MALLEY JP, 1991, J AM WATER WORKS ASS, V83, P56
[9]  
PLUMMER JD, 1995, AWWA SEP, P85
[10]   DAF TREATMENT OF A RESERVOIR WATER-SUPPLY - COMPARISON WITH IN-LINE DIRECT-FILTRATION AND CONTROL OF ORGANIC-MATTER [J].
SCHMIDT, PD ;
TOBIASON, JE ;
EDZWALD, JK ;
DUNN, H .
WATER SCIENCE AND TECHNOLOGY, 1995, 31 (3-4) :103-111