Contradictory working length effects in locked plating of the distal and middle femoral fractures a biomechanical study

被引:8
作者
Chao, Ching-Kong [1 ]
Chen, You-Lin [1 ]
Wu, Jian-Ming [1 ]
Lin, Chen-Huei [1 ]
Chuang, Ting-Yu [1 ]
Lin, Jinn [2 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, 43,Sec 4,Keelung Rd,Sect 4, Taipei, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Orthoped Surg, 7 Chung Shan S Rd, Taipei 10002, Taiwan
关键词
Femoral fractures; Locking plate; Plate stress; Working length; FEMUR FRACTURES; LOCKING PLATES; FIXATION; FAILURE; STRAIN; STABILITY; INCREASE; SPAN;
D O I
10.1016/j.clinbiomech.2020.105198
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Working length have been reported to affect the plate stress and fixation stiffness. However, the results of previous studies have been controversial. The present study was to determine working length effects on different locations of femoral bone gap. Methods: Five composite femurs with wide bone gaps at five levels (G1, 2, 3, 5, and 7), were fixed with locking plates. G1-3, G5 and G7 represented gaps at distal femur, distal-middle femur and middle femur respectively. Strain gauges were applied near the screw holes. The plate-bone constructs were loaded through a hemicylinder on the femoral head with total constraints at the distal femur. The micro-strains, axial stiffness and interfragmentary motions were recorded. Then the locking screws were removed one by one and the tests were re-run. The working length effects were compared and correlated. Findings: In distal femurs (G1-3), long working length was negatively correlated with the highest strains (r 0.97, 0.95 and 0.95, p < 0.01) and axial stiffness (r = -1, -0.96 and -0.99, p < 0.01). In distal-middle femurs (G5), as the working length increased, the highest strain decreased initially and then increased (r 0.81, p = 0.026) and the axial stiffness decreased (r = -0.98, p < 0.01). In middle femurs (G7), the highest strain and gap motions were much higher than that in the other groups and not significantly correlated with the working length change. Interpretation: Long working length could reduce the highest plate strain in distal femurs, but had no significant effects in middle femurs. The working length effects were markedly affected by the loading and boundary conditions.
引用
收藏
页数:8
相关论文
共 30 条
[1]   Pitfalls and limits of locking plates [J].
Bel, Jean-Christophe .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (01) :S103-S109
[2]   Stress Modulation of Fracture Fixation Implants [J].
Beltran, Michael J. ;
Collinge, Cory A. ;
Gardner, Michael J. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (10) :711-719
[3]   Management of Distal Femur Fractures With Modern Plates and Nails: State of the Art [J].
Beltran, Michael J. ;
Gary, Joshua L. ;
Collinge, Cory A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (04) :165-172
[4]   Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate [J].
Chao, Peini ;
Conrad, Bryan P. ;
Lewis, Daniel D. ;
Horodyski, MaryBeth ;
Pozzi, Antonio .
BMC VETERINARY RESEARCH, 2013, 9
[5]   Screw position affects dynamic compression plate strain in an in vitro fracture model [J].
Ellis, T ;
Bourgeault, CA ;
Kyle, RF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (05) :333-337
[6]   Failure of Fracture Plate Fixation [J].
Gardner, Michael J. ;
Evans, Jason M. ;
Dunbar, Robert P. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (10) :647-657
[7]   Guidelines for the clinical application of the LCP [J].
Gautier, E ;
Sommer, C .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 :63-76
[8]   The Influence of Fracture Fixation Biomechanics on Fracture Healing [J].
Hak, David J. ;
Toker, Serdar ;
Yi, Chengla ;
Toreson, Jeffrey .
ORTHOPEDICS, 2010, 33 (10) :752-755
[9]   Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures [J].
Harvin, William H. ;
Oladeji, Lasun O. ;
Della Rocca, Gregory J. ;
Murtha, Yvonne M. ;
Volgas, David A. ;
Stannard, James P. ;
Crist, Brett D. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (11) :2597-2601
[10]   2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur Fractures [J].
Henderson, Christopher E. ;
Lujan, Trevor J. ;
Kuhl, Lori L. ;
Bottlang, Michael ;
Fitzpatrick, Daniel C. ;
Marsh, John L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) :1757-1765