The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development

被引:26
|
作者
Telyshev, Dmitry [1 ]
Denisov, Maxim [1 ]
Pugovkin, Alexander [1 ]
Selishchev, Sergey [1 ]
Nesterenko, Igor [1 ]
机构
[1] Natl Res Univ Elect Technol, Biomed Syst Dept, Moscow 124635, Russia
关键词
Congestive heart failure; Mechanical circulatory support; Mock circulatory loop; Pediatric rotary blood pump; VENTRICULAR ASSIST DEVICE; COMPUTATIONAL FLUID-DYNAMICS; HEARTMATE II; FLOW; DESIGN;
D O I
10.1111/aor.13109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, the study results of an implantable pediatric rotary blood pump (PRBP) are presented. They show the results of the numerical simulation of fluid flow rates in the pump. The determination method of the backflows and stagnation regions is represented. The operating points corresponding to fluid flow rates of 1, 3, and 5 L/min for 75-80 mm Hg pressure head are investigated. The study results have shown that use of the pump in the 1 L/min operating point can potentially lead to the appearance of backflows and stagnation regions. In the case of using pumps in fluid flow rates ranging from 3 to 5 L/min, the number of stagnation regions decreases and the fluid flow rate changes marginally. Using the pump in this flow rate range is considered judicious. The study shows an increase in shear stress with an increase in fluid flow rates, while there is no increase in shear stress above the critical condition of 150 Pa (which does not allow us to reliably speak about the increased risk of blood cell damage). The aim of this work was to design, prototype, and study interaction of the Sputnik PRBP with the cardiovascular system. A three-dimensional model of Sputnik PRBP was designed with the following geometrical specifications: flow unit length of 51.5 mm, flow unit diameter of 10 mm, and spacing between the rotor and housing of 0.1 mm. Computational fluid dynamics studies were used to calculate head pressure-flow rate (H-Q) curves at rotor speeds ranging from 10 000 to 14 000 rpm (R-2 = 0.866 between numerical simulation and experiment) and comparing flow patterns at various points of the flow rate operating range (1, 3, and 5 L/min) for operating pressures ranging from 75 to 80 mm Hg. It is noted that when fluid flow rate changes from 1 L/min to 3 L/min, significant changes are observed in the distribution of zero flow zones. At the inlet and outlet of the pump, when going to the operating point of 3 L/min, zones of stagnation become minuscule. The shear stress distribution was calculated along the pump volume. The volume in which shear stress exceed 150 Pa is less than 0.38% of the total pump volume at flow rates of 1, 3, and 5 L/min. In this study, a mock circulatory system (MCS) allowing simulation of physiological cardiovascular characteristics was used to investigate the interaction of the Sputnik PRBP with the cardiovascular system. MCS allows reproducing the Frank-Starling autoregulation mechanism of the heart. PRBP behavior was tested in the speed range of 6 000 to 15 000 rpm. Decreased contractility can be expressed in a stroke volume decrease approximately from 18 to 4 mL and ventricle systolic pressure decrease approximately from 92 to 20 mm Hg. The left ventricle becomes fully supported at a pump speed of 10 000 rpm. At a pump speed of 14 000 rpm, the left ventricle goes into a suction state in which fluid almost does not accumulate in the ventricle and only passes through it to the pump. The proposed PRBP showed potential for improved clinical outcomes in pediatric patients with a body surface area greater than 0.6 m(2) and weight greater than 12 kg.
引用
收藏
页码:432 / 443
页数:12
相关论文
共 50 条
  • [31] Impeller behavior and displacement of the VentrAssist implantable rotary blood pump
    Chung, MKH
    Zhang, N
    Tansley, TD
    Woodard, JC
    ARTIFICIAL ORGANS, 2004, 28 (03) : 287 - 297
  • [32] Computational fluid dynamics as a development tool for rotary blood pumps
    Burgreen, GW
    Antaki, JF
    Wu, ZJ
    Holmes, AJ
    ARTIFICIAL ORGANS, 2001, 25 (05) : 336 - 340
  • [33] Development of a Closed Air Loop Electropneumatic Actuator for Driving a Pneumatic Blood Pump
    Jeong, Gi Seok
    Hwang, Chang Mo
    Nam, Kyoung Won
    Ahn, Chi Bum
    Kim, Ho Chul
    Lee, Jung Joo
    Choi, Jaesoon
    Son, Ho Sung
    Fang, Yong Hu
    Son, Kuk Hui
    Lim, Choon Hak
    Sun, Kyung
    ARTIFICIAL ORGANS, 2009, 33 (08) : 657 - U2
  • [34] Interaction of an Idealized Cavopulmonary Circulation With Mechanical Circulatory Assist Using an Intravascular Rotary Blood Pump
    Bhavsar, Sonya S.
    Moskowitz, William B.
    Throckmorton, Amy L.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 816 - 827
  • [35] Simulation of Changes in Myocardial Tissue Properties During Left Ventricular Assistance With a Rotary Blood Pump
    Martina, Jerson R.
    Bovendeerd, Peter H. M.
    de Jonge, Nicolaas
    de Mol, Bas A. J. M.
    Lahpor, Jaap R.
    Rutten, Marcel C. M.
    ARTIFICIAL ORGANS, 2013, 37 (06) : 531 - 540
  • [36] A NEW METHOD FOR ASSESSING HAEMOLYSIS IN A ROTARY BLOOD PUMP USING LARGE EDDY SIMULATIONS (LES)
    Szwast, Maciej
    Moskal, Arkadiusz
    Piatkiewicz, Wojciech
    CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2017, 38 (02): : 231 - 239
  • [37] Feasibility of the Optical Imaging of Thrombus Formation in a Rotary Blood Pump by Near-Infrared Light
    Sakota, Daisuke
    Murashige, Tomotaka
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    ARTIFICIAL ORGANS, 2014, 38 (09) : 733 - 740
  • [38] Assessment of Aortic Valve Opening During Rotary Blood Pump Support Using Pump Signals
    Granegger, Marcus
    Schima, Heinrich
    Zimpfer, Daniel
    Moscato, Francesco
    ARTIFICIAL ORGANS, 2014, 38 (04) : 290 - 297
  • [39] EFFECT OF TUBING LENGTH PUMP ON FLOW DERIVED INDEX DURING ROTARY BLOOD PUMP SUPPORT
    Khienwad, Thananya
    Deepankaew, Ronnachit
    Wannawat, Praemai
    Naiyanetr, Phornphop
    2017 13TH IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING (BIOMED), 2017, : 270 - 276
  • [40] Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump
    Chung, MKH
    Zhang, N
    Tansley, GD
    Qian, Y
    ARTIFICIAL ORGANS, 2004, 28 (12) : 1089 - 1094