Incorrect frozen elephant trunk deployment into the false lumen of a patient with complicated type B acute dissection

被引:12
作者
Fujii, Masahiko [1 ]
Watanabe, Hiroyuki [1 ]
Otsu, Masayoshi [1 ]
Sugahara, Yuta [1 ]
机构
[1] Narita Red Cross Hosp, Div Cardiovasc Surg, 90-1 Iida Cho, Narita, Chiba 2860041, Japan
关键词
Aortic dissection; Frozen elephant trunk; Aortic arch;
D O I
10.1093/ejcts/ezy357
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Total arch replacement with frozen elephant trunk (FET) is used for type B acute aortic dissection with insufficient proximal landing zone. Herein, we report incorrect deployment of FET into the false lumen. A 45-year-old man underwent femorofemoral bypass for complicated type B acute aortic dissection. However, chest pain recurred 4days postoperatively, and an oozing rupture of the dissecting descending aorta was diagnosed. As preoperative computed tomography showed insufficient proximal landing zone and separate chronic aortic dissection of the proximal arch, total arch replacement with FET was performed. Progressive lactic acidosis occurred on postoperative day 2, and computed tomography showed incorrect deployment of the FET into the false lumen, causing true lumen stenosis and intestinal ischaemia. Despite extensive enterectomy and abdominal aorta fenestration for the improvement of true lumen perfusion, the patient died of multiorgan failure on postoperative day 7. Care is required to avoid incorrect deployment of FET when there is a large entry in the proximal descending aorta.
引用
收藏
页码:1222 / 1224
页数:3
相关论文
共 4 条
[1]   True-lumen and false-lumen diameter changes in the downstream aorta after frozen elephant trunk implantation [J].
Berger, Tim ;
Kreibich, Maximilian ;
Morlock, Julia ;
Kondov, Stoyan ;
Scheumann, Johannes ;
Kari, Fabian A. ;
Rylski, Bartosz ;
Siepe, Matthias ;
Beyersdorf, Friedhelm ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (02) :375-381
[2]   Thoracic Endovascular Aortic Repair for Chronic DeBakey IIIb Aortic Dissection [J].
Hughes, G. Chad ;
Ganapathi, Asvin M. ;
Keenan, Jeffrey E. ;
Englum, Brian R. ;
Hanna, Jennifer M. ;
Schechter, Matthew A. ;
Wang, Hanghang ;
McCann, Richard L. .
ANNALS OF THORACIC SURGERY, 2014, 98 (06) :2092-2098
[3]   The frozen elephant trunk technique for the treatment of acute complicated Type B aortic dissection [J].
Kreibich, Maximilian ;
Berger, Tim ;
Morlock, Julia ;
Kondov, Stoyan ;
Scheumann, Johannes ;
Kari, Fabian A. ;
Rylski, Bartosz ;
Siepe, Matthias ;
Beyersdorf, Friedhelm ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (03) :525-530
[4]   Impact of clinical factors and surgical techniques on early outcome of patients treated with frozen elephant trunk technique by using EVITA open stent-graft: results of a multicentre studyaEuro [J].
Leontyev, Sergey ;
Tsagakis, Konstantinos ;
Pacini, Davide ;
Di Bartolomeo, Roberto ;
Mohr, Friedrich W. ;
Weiss, Gabriel ;
Grabenwoeger, Martin ;
Mascaro, Jorge G. ;
Iafrancesco, Mauro ;
Franke, Ulrich F. ;
Goebel, Nora ;
Sioris, Thanos ;
Widenka, Kazimierz ;
Mestres, Carlos A. ;
Jakob, Heinz .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (02) :660-666