Removal of cement-augmented screws in distal femoral fractures and the effect of retained screws and cement on total knee arthroplasty: a biomechanical investigation

被引:3
作者
Waehnert, Dirk [1 ,2 ]
Grueneweller, Niklas [1 ]
Gueorguiev, Boyko [2 ]
Vordemvenne, Thomas [1 ]
Gehweiler, Dominic [2 ]
机构
[1] Bielefeld Univ, Univ Hosp OWL, Protestant Hosp, Dept Trauma & Orthoped Surg,Bethel Fdn, Campus Bielefeld Bethel,Burgsteig 13, D-33617 Bielefeld, Germany
[2] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
关键词
Screw augmentation; Distal femoral fracture; Biomechanics; Total knee arthroplasty; Osteoporosis;
D O I
10.1186/s10195-021-00568-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Given the increasing number of osteoporotic fractures of the distal femur, screw augmentation with bone cement is an option to enhance implant anchorage. However, in implant removal or revision surgeries, the cement cannot be removed from the distal femur without an extended surgical procedure. Therefore, the aims of this study were to investigate (1) whether cement augmentation has any influence on screw removal and removal torque, and (2) whether the implantation of a femoral component of a knee arthroplasty and its initial interface stability are affected by the remaining screws/cement. Material and methods Eight pairs of fresh-frozen human female cadaveric distal femurs (mean age, 86 years) with a simulated AO/OTA 33 A3 fracture were randomized in paired fashion to two groups and fixed with a distal femoral locking plate using cannulated perforated locking screws. Screw augmentation with bone cement was performed in one of the groups, while the other group received no screw augmentation. Following biomechanical testing until failure (results published separately), the screws were removed and the removal torque was measured. A femoral component of a knee arthroplasty was then implanted, and pull-out tests were performed after cement curing. Interference from broken screws/cement was assessed, and the maximum pull-out force was measured. Results The mean screw removal torque was not significantly different between the augmented (4.9 Nm, SD 0.9) and nonaugmented (4.6 Nm, SD 1.3, p = 0.65) screw groups. However, there were significantly more broken screws in in the augmented screw group (17 versus 9; p < 0.001). There was no significant difference in the pull-out force of the femoral component between the augmented (2625 N, SD 603) and nonaugmented (2653 N, SD 542, p = 0.94) screw groups. Conclusion The screw removal torque during implant removal surgery does not significantly differ between augmented and nonaugmented screws. In the augmented screw group, significantly more screws failed. To overcome this, the use of solid screws in holes B, C, and G can be considered. Additionally, it is possible to implant a femoral component for knee arthroplasty that retains the initial anchorage and does not suffer from interference with broken screws and/or residual cement.
引用
收藏
页数:8
相关论文
共 16 条
  • [1] ARNESON TJ, 1988, CLIN ORTHOP RELAT R, P188
  • [2] Revision of Cannulated and Perforated Cement-Augmented Pedicle Screws A Biomechanical Study in Human Cadavers
    Bullmann, Viola
    Schmoelz, Werner
    Richter, Marcus
    Grathwohl, Corinna
    Schulte, Tobias L.
    [J]. SPINE, 2010, 35 (19) : E932 - E939
  • [3] Pedicle Screw Design and Cement Augmentation in Osteoporotic Vertebrae Effects of Fenestrations and Cement Viscosity on Fixation and Extraction
    Choma, Theodore J.
    Pfeiffer, Ferris M.
    Swope, Ryan W.
    Hirner, Jesse P.
    [J]. SPINE, 2012, 37 (26) : E1628 - E1632
  • [4] Retrograde locking nail fixation of distal femoal fractures with the distal femur nail (DFN)
    Grass, R
    Biewener, A
    Rammelt, S
    Zwipp, H
    [J]. UNFALLCHIRURG, 2002, 105 (04): : 298 - 314
  • [5] Locked Plating of Periprosthetic Femur Fractures Above Total Knee Arthroplasty
    Hou, Zhiyong
    Bowen, Thomas R.
    Irgit, Kaan
    Strohecker, Kent
    Matzko, Michelle E.
    Widmaier, James
    Smith, Wade R.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (07) : 427 - 432
  • [6] The Use of DensiProbe™ in Hindfoot Arthrodesis. Can Fusion Failure be Predicted by Mechanical Bone Strength Determination?
    Klos, K.
    Mueckley, T.
    Waehnert, D.
    Zwipp, H.
    Gueorguiev, B. G.
    Schwieger, K.
    Hofmann, G. O.
    Windolf, M.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2011, 149 (02): : 206 - 211
  • [7] Women with low-energy fracture should be investigated for osteoporosis
    Lofman, Owe
    Hallberg, Inger
    Berglund, Kenneth
    Wahlstrom, Ola
    Kartous, Lisa
    Rosenqvist, Anna-Maria
    Larsson, Lasse
    Toss, Goeran
    [J]. ACTA ORTHOPAEDICA, 2007, 78 (06) : 813 - 821
  • [8] Patient Mortality in Geriatric Distal Femur Fractures
    Myers, Philip
    Laboe, Patrick
    Johnson, Kory J.
    Fredericks, Peter D.
    Crichlow, Renn J.
    Maar, Dean C.
    Weber, Timothy G.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (03) : 111 - 115
  • [9] Biomechanical Evaluation of a Novel Fenestrated Pedicle Screw Augmented With Bone Cement in Osteoporotic Spines
    Pare, Philippe E.
    Chappuis, James L.
    Rampersaud, Raja
    Agarwala, Amit O.
    Perra, Joseph H.
    Erkan, Serkan
    Wu, Chunhui
    [J]. SPINE, 2011, 36 (18) : E1210 - E1214
  • [10] Primary total knee arthroplasty for complex distal femur fractures in elderly patients
    Rosen, AL
    Strauss, E
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) : 101 - 105