Accuracy of coronary flow measurements performed by means of Doppler wires

被引:11
作者
Doriot, PA [1 ]
Dorsaz, PA [1 ]
Dorsaz, L [1 ]
Chatelain, P [1 ]
机构
[1] Univ Hosp Geneva, Ctr Cardiol, Div Cardiol, CH-1211 Geneva 14, Switzerland
关键词
Doppler wire; coronary flow measurement;
D O I
10.1016/S0301-5629(99)00133-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
nTo estimate in patients the accuracy of coronary flow measurements performed by means of 0.014" Doppler wires, the time-averaged maximal blood velocity (APV) was recorded in the 3 branches of 36 angiographically normal coronary artery bifurcations selected in 21 patients undergoing cardiac catheterization for various diseases. Contrast medium injections filmed under two incidences allowed identification of the 3 sample volume locations and computing of the 3 corresponding vessel cross-sectional areas (CSA) at subsequent data analysis. Multiplication of the velocities APV/2 (range: 3 to 20.5 cm/s) by the CSA (obtained by averaging the two calibrated vessel diameters; range: 1.6 to 5.4 mm) yielded 108 flow rates (range: 5.4 to 169 mL/min), The average relative how error was then estimated using the continuity equation (Q(in) = Q(out,1) + Q(out,2)) > and the central limit theorem. The result was that the relative flow error decreased from 30% at Q = 30 mL/min to 13% at Q = 160 mL/min. We conclude that coronary flow measurements are reasonably accurate, except perhaps for very low flows. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 13 条
[1]   MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW BY SIMULTANEOUS INTRAVASCULAR 2-DIMENSIONAL AND DOPPLER ULTRASOUND - VALIDATION IN AN ANIMAL-MODEL [J].
CHOU, TM ;
SUDHIR, K ;
IWANAGA, S ;
CHATTERJEE, K ;
YOCK, PG .
AMERICAN HEART JOURNAL, 1994, 128 (02) :237-243
[2]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[3]  
Jenni R, 1998, CATHETER CARDIO DIAG, V44, P28, DOI 10.1002/(SICI)1097-0304(199805)44:1<28::AID-CCD8>3.0.CO
[4]  
2-9
[5]  
Jenni R, 1998, CATHETER CARDIO DIAG, V45, P96, DOI 10.1002/(SICI)1097-0304(199809)45:1<96::AID-CCD23>3.0.CO
[6]  
2-I
[7]  
Jost S, 1990, Int J Card Imaging, V5, P125, DOI 10.1007/BF01833981
[8]   Blood flow imaging and volume flow quantitation with intravascular ultrasound [J].
Li, WG ;
van der Steen, AFW ;
Lancee, CT ;
Cespedes, I ;
Bom, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (02) :203-214
[9]  
Papoulis A., 1984, Probability, Random Variables and Stochastic Processes, V2nd
[10]   ASSESSMENT OF SHORT-TERM, MEDIUM-TERM, AND LONG-TERM VARIATIONS IN ARTERIAL DIMENSIONS FROM COMPUTER-ASSISTED QUANTITATION OF CORONARY CINEANGIOGRAMS [J].
REIBER, JHC ;
SERRUYS, PW ;
KOOIJMAN, CJ ;
WIJNS, W ;
SLAGER, CJ ;
GERBRANDS, JJ ;
SCHUURBIERS, JCH ;
DENBOER, A ;
HUGENHOLTZ, PG .
CIRCULATION, 1985, 71 (02) :280-288