Automated HPLC analysis of glutathione and thiol-containing compounds in grape juice and wine using pre-column derivatization with fluorescence detection

被引:71
作者
Park, SK
Boulton, RB
Noble, AC [1 ]
机构
[1] Univ Calif Davis, Dept Viticulture & Enol, Davis, CA 95616 USA
[2] Kyung Hee Univ, Dept Food Sci & Technol, Kyonggi Do, South Korea
关键词
grape juice; HPLC; glutathione; thiols;
D O I
10.1016/S0308-8146(99)00227-7
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
An easy and sensitive method for the analysis of glutathione (GSH) and other thiol-containing compounds in grape juice and wine has been developed and optimized. Following a pre-column derivatization of thiols with o-phthalaldehyde (OPA) and 2 aminoethanol, isoindole derivatives are separated on reversed-phase HPLC column and quantified by a fluorescence detector. The minimum detection limits for thiols are: GSH, 3.3 nmol/l(1 mu g/l); cysteine, 22 mu mol/l (2.7 mg/L); methanethiol, 0.27 mu mol/l(12.8 mu g/l); ethanethiol, 0.65 mu mol/l (11 mu g/l). The method yields linear responses up to 40 and 21 mg/l for GSH and cysteine, respectively. GSH levels in two varietal grape juices during fermentation varied from 0 (starting juice) to 2.1 mg/l (wine) in Sauvignon blanc, while the GSH in a Palomino sample with 1.28 mg/l in the juice increased to 5.1 mg/l in the wine. This automated pre-column derivatization of thiols followed by an automatic injection procedure is sensitive, reproducible and rapid, with a run time of 35 min. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:475 / 480
页数:6
相关论文
共 21 条
[1]  
CHEYNIER V, 1989, AM J ENOL VITICULT, V40, P320
[2]   GLUTATHIONE AS AN ENDOGENOUS SULFUR SOURCE IN THE YEAST SACCHAROMYCES-CEREVISIAE [J].
ELSKENS, MT ;
JASPERS, CJ ;
PENNINCKX, MJ .
JOURNAL OF GENERAL MICROBIOLOGY, 1991, 137 :637-644
[3]  
Jocelyn P.C., 1972, Biochemistry of the SH group: the occurrence, chemical properties, metabolism and biological function of thiols and disulphides
[4]   DEVELOPMENT OF FLUORESCENCE BETWEEN ORTHO-PHTHALDIALDEHYDE AND THIOLS [J].
JOCELYN, PC ;
KAMMINGA, A .
ANALYTICAL BIOCHEMISTRY, 1970, 37 (02) :417-&
[5]  
LARSSON A, 1983, FUNCTION GLUTATHIONE
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF SUBPICOMOLE AMOUNTS OF AMINO-ACIDS BY PRECOLUMN FLUORESCENCE DERIVATIZATION WITH ORTHO-PHTHALDIALDEHYDE [J].
LINDROTH, P ;
MOPPER, K .
ANALYTICAL CHEMISTRY, 1979, 51 (11) :1667-1674
[7]   GLUTATHIONE [J].
MEISTER, A ;
ANDERSON, ME .
ANNUAL REVIEW OF BIOCHEMISTRY, 1983, 52 :711-760
[8]   TRACE DETERMINATION OF BIOLOGICAL THIOLS BY LIQUID-CHROMATOGRAPHY AND PRECOLUMN FLUOROMETRIC LABELING WITH ORTHO-PHTHALALDEHYDE [J].
MOPPER, K ;
DELMAS, D .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2557-2560
[9]   RELATIONSHIP BETWEEN GLUTATHIONE CONTENTS AND GENERATION TIMES IN SACCHAROMYCES-CEREVISIAE [J].
MURATA, K ;
KIMURA, A .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1986, 50 (04) :1055-1056
[10]   FLUOROMETRIC-DETERMINATION OF THIOLS BY LIQUID-CHROMATOGRAPHY WITH POSTCOLUMN DERIVATIZATION [J].
NAKAMURA, H ;
TAMURA, Z .
ANALYTICAL CHEMISTRY, 1981, 53 (14) :2190-2193