Thermal Performance of Load-Bearing, Lightweight, Steel-Framed Partition Walls Using Thermal Break Strips: A Parametric Study

被引:6
作者
Santos, Paulo [1 ]
Lopes, Paulo [1 ]
Abrantes, David [1 ]
机构
[1] Univ Coimbra, Dept Civil Engn, ISISE, P-3030788 Coimbra, Portugal
关键词
thermal performance; lightweight steel framed; partition walls; thermal break strips; parametric study; cross-section dimensions; thermal conductivity; stud spacing; number; BRIDGES; BUILDINGS; IMPACT;
D O I
10.3390/en15249271
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal bridges are a very relevant issue for lightweight steel-framed (LSF) construction systems given the high thermal conductivity of steel, which can negatively compromise their thermal behaviour, reduce their durability, and decrease the building energy efficiency. Several thermal bridge mitigation strategies exist, including the attachment of thermal break strips (TBS) to the steel studs' flanges as one of the most widely employed techniques. In this research, the relevance of TBS to the thermal performance improvement of load-bearing LSF partition walls was assessed by performing a parametric study, making use of a validated 2D numerical model. A sensitivity analysis was performed for five different key parameters, and their importance was evaluated. The assessed parameters included the number of TBS and their thickness, width, and thermal conductivity, as well as the vertical steel stud spacing. We found that these parameters were all relevant. Moreover, regardless of the TBS thermal conductivity, it is always worth increasing their thickness. However, the increase in the TBS width does not always lead to increased thermal resistance; a thermal performance reduction was noted when increasing the width of the TBS at higher thermal conductivities. Therefore, it was concluded that it is more efficient to increase TBS thickness than their width.
引用
收藏
页数:16
相关论文
共 30 条
[21]   Thermal Performance of Load Bearing Cold-formed Steel Walls under Fire Conditions using Numerical Studies [J].
Keerthan, Poologanathan ;
Mahendran, Mahen .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2014, 5 (03) :261-289
[22]   Experimental study of non-load bearing light gauge steel framed walls in fire [J].
Ariyanayagam, Anthony Deloge ;
Mahendran, Mahen .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 145 :529-551
[23]   Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy [J].
Kishore, Ravi Anant ;
Bianchi, Marcus V. A. ;
Booten, Chuck ;
Vidal, Judith ;
Jackson, Roderick .
APPLIED THERMAL ENGINEERING, 2020, 180
[24]   THERMAL MODELLING OF LOAD BEARING COLD-FORMED STEEL FRAME WALLS UNDER REALISTIC DESIGN FIRE CONDITIONS [J].
Ariyanayagam, A. D. ;
Keerthan, P. ;
Mahendran, M. .
ADVANCED STEEL CONSTRUCTION, 2017, 13 (02) :160-189
[25]   Case Study in Modular Lightweight Steel Frame Construction: Thermal Bridges and Energy Performance Assessment [J].
Milovanovic, Bojan ;
Bagaric, Marina ;
Gasi, Mergim ;
Strmo, Nikolina Vezilic .
APPLIED SCIENCES-BASEL, 2022, 12 (20)
[26]   Experimental and Numerical Characterization of the In-Plane Shear Behavior of a Load-Bearing Hollow Clay Brick Masonry System with High Thermal Performance [J].
Serpilli, Michele ;
Cameli, Alessandro ;
Stazi, Francesca .
BUILDINGS, 2024, 14 (09)
[27]   A numerical study on the effect of phase-change material (PCM) parameters on the thermal performance of lightweight building walls [J].
Liu, Zu'an ;
Hou, Jiawen ;
Meng, Xi ;
Dewancker, Bart Julien .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2021, 15
[28]   Development of a lightweight building simulation tool using simplified zone thermal coupling for fast parametric study [J].
Shen, Pengyuan ;
Braham, William ;
Yi, Yunkyu .
APPLIED ENERGY, 2018, 223 :188-214
[29]   Thermal and mechanical transient behaviour of steel doors installed in non-load-bearing partition wall assemblies during exposure to the standard fire test [J].
Nassif, Ayman Y. ;
Yoshitake, Isamu ;
Vimonsatit, Vanissorn .
FIRE AND MATERIALS, 2016, 40 (08) :1070-1089
[30]   A Parametric Study on the Thermal Performance of Unglazed Solar Water Collectors with Their Colorbond Steel Absorber Plates Also Used as Roofs [J].
Walsh, Matthew ;
Lin, Wenxian .
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2015, 12 (12) :1309-1322