Reconstruction of PET images with a compressed Monte Carlo based system matrix - a comparison to other Monte Carlo based algorithms

被引:0
作者
Rehfeld, Niklas
Fippel, Matthias
Alber, Markus
机构
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
positron emission tomography; reconstruction; Monte Carlo; system matrix; compression;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method to compress the system matrix of a PET scanner calculated by Monte Carlo (MC) simulations is introduced. The proposed method reduces the size of the matrix drastically and allows a considerable reduction in the number of simulated particles. The images reconstructed with such a compressed matrix are compared to images reconstructed with other MC based algorithms, naively the dual-matrix algorithm [1] and the full-matrix algorithm (reconstruction using the uncompressed MC matrix).
引用
收藏
页码:2286 / 2290
页数:5
相关论文
共 50 条
[21]   Characterization of the ringing artifacts in rotator-based reconstruction with Monte Carlo-based resolution compensation for PET [J].
Zhang, Long ;
Staelens, Steven ;
Van Holen, Roel ;
Verhaeghe, Jeroen ;
Vandenberghe, Stefaan .
MEDICAL PHYSICS, 2010, 37 (09) :4648-4660
[22]   Monte Carlo Based Ensemble Forecasting [J].
L. Mark Berliner .
Statistics and Computing, 2001, 11 :269-275
[23]   Monte Carlo based ensemble forecasting [J].
Berliner, LM .
STATISTICS AND COMPUTING, 2001, 11 (03) :269-275
[24]   LuCaS: Efficient Monte Carlo simulations of highly realistic PET tumor images [J].
Stute, Simon ;
Tylski, Perrine ;
Grotus, Nicolas ;
Buvat, Irene .
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, :3285-3287
[25]   Gray: a ray tracing-based Monte Carlo simulator for PET [J].
Freese, David L. ;
Olcott, Peter D. ;
Buss, Samuel R. ;
Levin, Craig S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (10)
[26]   Reconstruction of optical coherence tomography image based on Monte Carlo method [J].
Wang, XY ;
Zhang, CP ;
Zhang, LS ;
Qi, SW ;
Xu, T ;
Tian, JG .
JOURNAL OF INFRARED AND MILLIMETER WAVES, 2003, 22 (01) :68-70
[27]   Monte-Carlo SURE for image reconstruction based on TV regularization [J].
Han, Y., 1600, Asian Network for Scientific Information (12) :3903-3908
[28]   gPET: a GPU-based, accurate and efficient Monte Carlo simulation tool for PET [J].
Lai, Youfang ;
Zhong, Yuncheng ;
Chalise, Ananta ;
Shao, Yiping ;
Jin, Mingwu ;
Jia, Xun ;
Chi, Yujie .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (24)
[29]   Geometrical and Monte Carlo projectors in 3D PET reconstruction [J].
Aguiar, Pablo ;
Rafecas, Magdalena ;
Enrique Ortuno, Juan ;
Kontaxakis, George ;
Santos, Andres ;
Pavia, Javier ;
Ros, Domenec .
MEDICAL PHYSICS, 2010, 37 (11) :5691-5702
[30]   Reliability Analysis of The Subway Door System Based on Monte Carlo [J].
Shi, F. Y. ;
Gao, X. D. ;
Xing, Z. Y. ;
Chen, Y. J. ;
Qin, Y. .
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMPUTER INFORMATION SYSTEMS AND INDUSTRIAL APPLICATIONS (CISIA 2015), 2015, 18 :330-333