Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system

被引:63
作者
D'Ilio, S. [1 ]
Violante, N. [1 ]
Di Gregorio, M. [1 ]
Senofonte, O. [1 ]
Petrucci, F. [1 ]
机构
[1] Ist Super Sanita, Dept Environm & Primary Prevent, I-00161 Rome, Italy
关键词
trace elements; blood; dynamic reaction cell inductively coupled plasma mass spectrometry; desolvating system;
D O I
10.1016/j.aca.2006.07.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quadrupole inductively coupled plasma mass spectrometer (Q-ICP-MS) equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulization system (APEX-IR) was employed to determine 17 elements (Al, As, Ba, Cd, Co, Cr, U, Mn, Mo, Ni, Pb, Sb, Se, Sn, Sr, V, and Zr) in blood samples. Ammonia (for Al, Cr, Mn, and V) and 02 (for As and Se) were used as reacting gases. Selection of the best flow rate of the gases and optimization of the quadrupole dynamic bandpass tuning parameter (RPq) were carried out, using digested blood diluted 1 + 9 with deionized water and spiked with 1 mu g L-1 of Al, Cr, Mn, V and 5 mu g L-1 of As and Se. Detection limits were determined in digested blood using the 3 sigma criterion. The desolvating system allowed a sufficient sensitivity to be achieved to determine elements at levels of ng L-1 without detriment of signal stability. The accuracy of the method was tested with the whole blood certified reference material (CRM), certified for Al, As, Cd, Co, Cr, Mn, Mo, Ni, Pb, Sb, Se, and V, and with indicative values for Ba, Li, Sn, Sr, and Zr. The addition calibration approach was chosen for analysis. In order to confirm the DRC data, samples were also analyzed by means of sector field inductively coupled plasma mass spectrometry (SF-ICP-MS), operating in medium (m/Delta m = 4000) and high (m/Delta m = 10,000) resolution mode and achieving a good agreement between the two techniques. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 36 条
[1]   Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :454-470
[2]   Relationships between trace element concentrations in human blood and serum [J].
Bárány, E ;
Bergdahl, IA ;
Bratteby, LE ;
Lundh, T ;
Samuelson, G ;
Schütz, A ;
Skerfving, S ;
Oskarsson, A .
TOXICOLOGY LETTERS, 2002, 134 (1-3) :177-184
[3]   Trace elements in blood and serum of Swedish adolescents:: Relation to gender, age, residential area, and socioeconomic status [J].
Bárány, E ;
Bergdahl, IA ;
Bratteby, LE ;
Lundh, T ;
Samuelson, G ;
Schütz, A ;
Skerfving, S ;
Oskarsson, A .
ENVIRONMENTAL RESEARCH, 2002, 89 (01) :72-84
[4]   Inductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum [J].
Barany, E ;
Bergdahl, IA ;
Schutz, A ;
Skerfving, S ;
Oskarsson, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :1005-1009
[5]   Aluminum as a toxicant [J].
Becaria, A ;
Campbell, A ;
Bondy, SC .
TOXICOLOGY AND INDUSTRIAL HEALTH, 2002, 18 (07) :309-320
[6]   Quantification of trace elements by sector field inductively coupled plasma mass spectrometry in urine, serum, blood and cerebrospinal fluid of patients with Parkinson's disease [J].
Bocca, B ;
Alimonti, A ;
Petrucci, F ;
Violante, N ;
Sancesario, G ;
Forte, G ;
Senofonte, O .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (04) :559-566
[7]   High-throughput microwave-digestion procedures to monitor neurotoxic elements in body fluids by means of inductively coupled plasma mass spectrometry [J].
Bocca, B ;
Alimonti, A ;
Forte, G ;
Petrucci, F ;
Pirola, C ;
Senofonte, O ;
Violante, N .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) :65-70
[8]   Determination of calcium, iron and zinc in milk powder by reaction cell inductively coupled plasma mass spectrometry [J].
Chen, KL ;
Jiang, SJ .
ANALYTICA CHIMICA ACTA, 2002, 470 (02) :223-228
[9]   Manganese toxicity upon overexposure [J].
Crossgrove, J ;
Zheng, W .
NMR IN BIOMEDICINE, 2004, 17 (08) :544-553
[10]   Sequential thoracentesis -: Minor change of zinc compared to other selected essential trace elements in the serum [J].
Domej, W ;
Tilz, GP ;
Demel, U ;
Földes-Papp, Z ;
Rabold, T ;
Goessler, W ;
Krachler, M ;
Lang, J .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2002, 87 (1-3) :29-43