Reactive Power Control Strategy of Demand Side Back-to-Back Converter Based on VSM

被引:1
作者
Lyu, Xiao [1 ]
Ma, Gang [1 ]
机构
[1] Nanjing Normal Univ, Sch Elect & Automat Engn, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
VSM; back-to-back converter; DSM; load power; reactive power control; supply and demand balance; LOAD CONTROL; STORAGE;
D O I
10.2174/2352096513999200702163413
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
VSM Background: The Demand Side Management (DSM) technology is playing an increasingly important role in the power system, in order to promote the real-time supply and demand balance of the power grid and improve the economy and safety of the power grid. Objective: To realize the flexible and continuous reactive power control of demand side load, a reactive power control strategy for the demand side back-to-back converter (DS-B2BC) is proposed. Methods: First, DS-13213C is proposed. Then, the reactive power control model of DS-13213C and its control loop are designed, and the reactive power control model, based on the Virtual Synchronous Motor (VSM), is established. Results: The simulation results verify that the reactive power control strategy proposed in this paper is effective, which can control the demand side load reactive power flexibly and continuously. Conclusion: Moreover, the strategy can counteract the disturbance from the power grid simultaneously.
引用
收藏
页码:1242 / 1255
页数:14
相关论文
共 26 条
[1]   Optimizing Load Control in a Collaborative Residential Microgrid Environment [J].
Ahmadi, Majid ;
Rosenberger, Jay M. ;
Lee, Wei-Jen ;
Kulvanitchaiyanunt, Asama .
IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (03) :1196-1207
[2]   Smart Loads for Voltage Control in Distribution Networks [J].
Akhtar, Zohaib ;
Chaudhuri, Balarko ;
Hui, Shu Yuen Ron .
IEEE TRANSACTIONS ON SMART GRID, 2017, 8 (02) :937-946
[3]   Combining the Demand Response of direct electric space heating and partial thermal storage using LP optimization [J].
Ali, Mubbashir ;
Jokisalo, Juha ;
Siren, Kai ;
Lehtonen, Matti .
ELECTRIC POWER SYSTEMS RESEARCH, 2014, 106 :160-167
[4]   Reactive power control for improving voltage profiles: A comparison between two decentralized approaches [J].
Calderaro, V. ;
Conio, G. ;
Galdi, V. ;
Piccolo, A. .
ELECTRIC POWER SYSTEMS RESEARCH, 2012, 83 (01) :247-254
[5]   Dynamic Modeling of Electric Springs [J].
Chaudhuri, Nilanjan Ray ;
Lee, Chi Kwan ;
Chaudhuri, Balarko ;
Hui, S. Y. Ron .
IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (05) :2450-2458
[6]  
Chen Y, 2012, P INT C REN EN POW Q, P1, DOI [DOI 10.24084/REPQJ10.453, DOI 10.1155/2012/510158]
[7]   Fast Distributed Demand Response Algorithm in Smart Grid [J].
Dong, Qifen ;
Yu, Li ;
Song, Wenzhan ;
Yang, Junjie ;
Wu, Yuan ;
Qi, Jun .
IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2017, 4 (02) :280-296
[8]   A control strategy for a distributed generation unit in grid-connected and autonomous modes of operation [J].
Gao, Fang ;
Iravani, M. Reza .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) :850-859
[9]   Optimal Industrial Load Control in Smart Grid [J].
Gholian, Armen ;
Mohsenian-Rad, Hamed ;
Hua, Yingbo .
IEEE TRANSACTIONS ON SMART GRID, 2016, 7 (05) :2305-2316
[10]   A physically-based model for simulating inverter type air conditioners/heat pumps [J].
Gomes, A. ;
Henggeler Antunes, C. ;
Martinho, J. .
ENERGY, 2013, 50 :110-119