Improvement of in situ Pb isotope analysis by LA-ICP-MS using a 193 nm Nd:YAG laser

被引:29
作者
Jochum, Klaus Peter [1 ]
Stoll, Brigitte [1 ]
Herwig, Kirstin [1 ]
Willbold, Matthias [1 ]
机构
[1] Max Planck Inst Chem, D-55020 Mainz, Germany
关键词
D O I
10.1039/b603890e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have tested the capabilities of a new 193 nm Nd:YAG laser ablation system for in situ Pb-208/Pb-206 and Pb-207/Pb-206 measurements by LA-ICP-MS. Experiments were performed with MPI-DING (KL2-G, ML3B-G, ATHO-G, T1-G) and USGS (GSE-1G) reference glasses using the fast electrical scan mode (0.075 s per pass) of a single collector sector-field mass spectrometer. Mass discrimination was determined by sample-reference material (e. g., NIST SRM 612) bracketing with linear interpolation. We typically obtained an external precision for Pb-208/Pb-206 and Pb-207/Pb-206 of 0.05-0.2% RSD for 50-100 mu m three-spot analyses of the low-Pb (1-10 mu g g(-1)) MPI-DING glasses. The precision of Pb isotope ratio data of the high-Pb GSE-1G sample (366 mu g g(-1)) was < 0.2% for spot sizes >= 10 mu m. Even 2 and 5 mu m spot size measurements could be performed with GSE-1G. The LA-ICP-MS isotope ratio data of the MPI-DING reference glasses agree within uncertainties (about 0.05% and 0.1% for Pb-208/Pb-206 and Pb-207/Pb-206, respectively, and 100 mm spot size analyses) with the reference values obtained from TIMS and solution MC-ICP-MS. A comparison of the 193 nm Nd:YAG laser results with those obtained from a 213 nm Nd:YAG laser system shows that there is almost a factor of two improvement in precision using the new 193 nm Nd: YAG laser. Because of lower sample consumption of the 193 nm Nd: YAG laser, the Pb detection efficiency (2.5 x 10(-3)) of the mass spectrometer is a factor of 2.5 higher than that using the 213 nm laser. Reasons for these improvements are the shorter wavelength (193 nm compared with 213 nm) and the shorter pulse width (2.8 ns compared to 5 ns) of the new laser ablation system. Thus, the mean particle size of the ablated material and the localized heating of the sample is reduced, leading to a more uniform mass discrimination.
引用
收藏
页码:666 / 675
页数:10
相关论文
共 18 条
[1]   Pb isotopic analysis of standards and samples using a 207Pb-204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS [J].
Baker, J ;
Peate, D ;
Waight, T ;
Meyzen, C .
CHEMICAL GEOLOGY, 2004, 211 (3-4) :275-303
[2]   Solid sample analysis using laser ablation inductively coupled plasma mass spectrometry [J].
Günther, D ;
Hattendorf, B .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :255-265
[3]   Evaluation and design of a solid-state 193 nm OPO-Nd:YAG laser ablation system [J].
Horn, I ;
Günther, D ;
Guillong, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (10) :1837-1846
[4]  
Jackson SE, 2001, MINERAL AS, V29, P105
[5]  
Jochum K. P., 2004, EOS T AM GEOPH UN FA, V85, pF1929
[6]   MPI-DING reference glasses for in situ microanalysis:: New reference values for element concentrations and isotope ratios [J].
Jochum, Klaus Peter ;
Stoll, Brigitte ;
Herwig, Kirstin ;
Willbold, Matthias ;
Hofmann, Albrecht W. ;
Amini, Marghaleray ;
Aarburg, Susanne ;
Abouchami, Wafa ;
Hellebrand, Eric ;
Mocek, Beate ;
Raczek, Ingrid ;
Stracke, Andreas ;
Alard, Olivier ;
Bouman, Claudia ;
Becker, Stefan ;
Duecking, Marc ;
Braetz, Helene ;
Klemd, Reiner ;
de Bruin, Deon ;
Canil, Dante ;
Cornell, Dave ;
de Hoog, Cees-Jan ;
Dalpe, Claude ;
Danyushevsky, Leonid ;
Eisenhauer, Anton ;
Gao, Yongjun ;
Snow, Jonathan E. ;
Goschopf, NOra ;
Gunther, D. ;
Latkoczy, Christopher ;
Guillong, Marcel ;
Hauri, Erik H. ;
Hoefer, Heidi E. ;
Lahaye, Yann ;
Horz, Kersten ;
Jacob, Dorrit E. ;
Kassemann, Simone A. ;
Kent, Adam J. R. ;
Ludwig, Thomas ;
Zack, Thomas ;
Mason, Paul R. D. ;
Meixner, Anette ;
Rosner, Martin ;
Misawa, Keiji ;
Nash, Barbara P. ;
Pfaender, Jorg ;
Premo, Wayne R. ;
Sun, Weidong ;
Tiepolo, Massimo ;
Vannucci, Riccardo .
GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2006, 7
[7]   Chemical characterisation of the USGS reference glasses GSA-1G, GSC-1G, GSD-1G, GSE-1G, BCR-2G, BHVO-2G and BIR-1G using EPMA, ID-TIMS, ID-ICP-MS and LA-ICP-MS [J].
Jochum, KP ;
Willbold, M ;
Raczek, I ;
Stoll, B ;
Herwig, K .
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2005, 29 (03) :285-302
[8]   GeoReM: A new geochemical database for reference materials and isotopic standards [J].
Jochum, KP ;
Nohl, L ;
Herwig, K ;
Lammel, E ;
Stoll, B ;
Hofmann, AW .
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2005, 29 (03) :333-338
[9]   Lead isotope ratio measurements in geological glasses by laser ablation-sector field-ICP mass spectrometry (LA-SF-ICPMS) [J].
Jochum, KP ;
Stoll, B ;
Herwig, K ;
Amini, A ;
Abouchami, W ;
Hofmann, AW .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) :281-289
[10]  
JOSHCUM KP, 2005, GEOCHEM GEOPHY GEOSY, V6, P10008, DOI DOI 10.1029/2005GC000995