Feasibility of a smartphone-based balance assessment system for subjects with chronic stroke

被引:23
|
作者
Hou, You-Ruei [1 ]
Chiu, Ya-Lan [1 ]
Chiang, Shang-Lin [2 ,3 ]
Chen, Hui-Ya [4 ]
Sung, Wen-Hsu [1 ]
机构
[1] Natl Yang Ming Univ, Dept Phys Therapy & Assist Technol, Taipei, Taiwan
[2] Triserv Hosp, Taipei, Taiwan
[3] Natl Def Med Ctr, Taipei, Taiwan
[4] Chung Shan Med Univ, Dept Phys Therapy, Taichung, Taiwan
关键词
Smartphone; Balance; Assessment; Stroke; STANDING BALANCE; PERFORMANCE; STABILITY; RECOVERY;
D O I
10.1016/j.cmpb.2018.04.027
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background: Stroke is a cerebral artery disease that may lead to long-term disabilities or death. Patients that survive a stroke usually suffer balance impairments, which affect their performance in activities of daily living (ADLs) and quality of life (QoL). In recent years, smartphones have become very popular and have many capabilities. Smartphone built-in sensors have shown their ability and potential in balance performance assessment. However, the feasibility of smartphones on subjects with chronic strokes remains to be proved. Therefore, the purpose of this study is to evaluate the feasibility of a smartphone-based balance assessment system for subjects with chronic stroke. Methods: Ten subjects with chronic stroke and thirteen healthy adults were recruited in the study. The smartphone HTC 10 (HTC Corporation, Taiwan) was used to perform the balance assessment, and its builtin accelerometer and gyroscope were used to record data from the subjects. Six postures were tested for thirty seconds each: shoulder-width stance (SWS) with eyes opened (E/O) and eyes closed (E/C), feet-together stance (FTS) with E/O and E/C, and semi-tandem stance (STS) with E/O and E/C. The smartphone was fixed to the back of subjects at the second sacral spine (S2) level. The changes registered in the accelerometer and gyroscope data were used to represent the balance performance, in which higher values indicate more instability. Data was analyzed using the independent t-test with the software SPSS 20, and the statistical significance level was set to alpha<0.05. Results and discussion: Significant difference in the acceleration data was found among subjects with chronic stroke and healthy adults under four assessment postures: SWS with E/C (p = 0.048), FTS with E/O (p = 0.027), FTS with E/C (p = 0.000), and STS with E/C (p = 0.048). Furthermore, according to the gyroscope data, there were significant differences in how the two groups performed the postures. The results demonstrate that a smartphone with a built-in accelerometer and gyroscope can be used to classify balance performances between healthy adults and subjects with chronic stroke. Conclusion: This study shows that smartphones are feasible to assess balance for subjects with chronic stroke. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 195
页数:5
相关论文
共 50 条
  • [21] The Design of a Smartphone-Based Fall Detection System
    Sie, Meng-Ruei
    Lo, Shou-Chih
    2015 IEEE 12TH INTERNATIONAL CONFERENCE ON NETWORKING, SENSING AND CONTROL (ICNSC), 2015, : 456 - 461
  • [22] A smartphone-based system for fluorescence polarization assays
    Zhao, Zijian
    Wei, Le
    Cao, Mingfeng
    Lu, Meng
    BIOSENSORS & BIOELECTRONICS, 2019, 128 : 91 - 96
  • [23] Development of Smartphone-based Student Attendance System
    Islam, Md. Milon
    Hasan, Md. Kamrul
    Billah, Md Masum
    Uddin, Md. Manik
    2017 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2017, : 230 - 233
  • [24] A Smartphone-based Fall Detection System for the Elderly
    Tsinganos, Panagiotis
    Skodras, Athanassios
    PROCEEDINGS OF THE 10TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS, 2017, : 53 - 58
  • [25] Smartphone-Based Visual Feedback Trunk Control Training Using a Gyroscope and Mirroring Technology for Stroke Patients: Single-blinded, Randomized Clinical Trial of Efficacy and Feasibility
    Shin, Doo Chul
    Song, Chang Ho
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2016, 95 (05) : 319 - 329
  • [26] A Wearable Smartphone-Based System for Electrocardiogram Acquisition
    Depari, A.
    Flammini, A.
    Sisinni, E.
    Vezzoli, A.
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 54 - 59
  • [27] SmartMic: a smartphone-based meeting support system
    Huang Xu
    Zhiwen Yu
    Zhu Wang
    Hongbo Ni
    The Journal of Supercomputing, 2014, 70 : 1318 - 1330
  • [28] Smartphone-based gait and balance accelerometry is sensitive to age and correlates with clinical and kinematic data
    Olsen, Sharon
    Rashid, Usman
    Allerby, Celia
    Brown, Eliza
    Leyser, Michaela
    McDonnell, Gabrielle
    Alder, Gemma
    Barbado, David
    Shaikh, Nusratnaaz
    Lord, Sue
    Niazi, Imran Khan
    Taylor, Denise
    GAIT & POSTURE, 2023, 100 : 57 - 64
  • [29] SmartMic: a smartphone-based meeting support system
    Xu, Huang
    Yu, Zhiwen
    Wang, Zhu
    Ni, Hongbo
    JOURNAL OF SUPERCOMPUTING, 2014, 70 (03) : 1318 - 1330
  • [30] Wearable Smartphone-Based Multisensory Feedback System for Torso Posture Correction: Iterative Design and Within-Subjects Study
    Pereira, Amanda Polin
    Machado Neto, Olibario Jose
    Elui, Valeria Meirelles Carril
    Pimentel, Maria da Graca Campos
    JMIR AGING, 2025, 8