Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock

被引:8
作者
Ballesteros, D. [1 ]
Martinez, O. [1 ]
Blancas Gomez-Casero, R. [1 ]
Martin Parra, C. [1 ]
Lopez Matamala, B. [1 ]
Estebanez, B. [1 ]
Chana, M. [1 ]
机构
[1] Hosp Univ Tajo, Dept Intens Care, Aranjuez, Spain
关键词
Glucose monitoring; Tissue glucose; Capillary glucose; Distributive shock; Critical illness; Hypoglycemia; INTENSIVE INSULIN THERAPY; CRITICALLY-ILL PATIENTS; STRESS HYPERGLYCEMIA; CARE-UNIT; MORTALITY; ACCURACY; SAFETY; DEATH; TRIAL; RISK;
D O I
10.1016/j.medin.2014.09.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. Methods: Consecutive patients admitted to the ICU with a diagnosis of distributive shock and the need of insulin infusion for glycemic control were included in the study. These patients were implanted a Continuous Glucose Control Monitoring System (CGMS) with the sensor inserted subcutaneously into the abdominal wall. CGMS values were recorded every 5 min. Capillary glucose (CG) was monitored for adjusting insulin perfusion according to the ICU protocol. Correlation between both methods was assessed. Results: A total of 11,673 CGMS and 348 CG values were recorded. In five patients, CGMS failed to detect tissue glucose. A glucose value <3.33 mmol/l (<60 mg/dl) was observed in 3.6% of CGMS and in 0.29% CG values. 295 pairs of measurements were included in the statistical analysis for correlation assessment. The intraclass correlation coefficient was 0.706. The Pearson correlation coefficient was 0.71 (p<0.0001, 95% CI 0.65-0.76). The mean of differences between both measurement methods was 0.22 mmol/l (3.98 mg/dl) (95% CI 0.66-7.31). Conclusions: When the Continuous Glucose Control Monitoring System (CGMS) is able to obtain data (75% of the patients), there is correlation between the values obtained by this method and capillary blood glucose in patients with distributive shock. CGMS can detect more episodes of glycemic excursions outside the normal range than intermittent capillary glucose monitoring. Variables that may impair glucose metabolism and peripheral soft tissues perfusion could impair CGMS measurements. (C) 2014 Elsevier Espana, S.L.U. and SEMICYUC. All rights reserved.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 38 条
[1]  
BABLOK W, 1988, J CLIN CHEM CLIN BIO, V26, P783
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Continuous glucose monitors prove highly accurate in critically ill children [J].
Bridges, Brian C. ;
Preissig, Catherine M. ;
Maher, Kevin O. ;
Rigby, Mark R. .
CRITICAL CARE, 2010, 14 (05)
[4]   Intensive insulin therapy and pentastarch resuscitation in severe sepsis [J].
Brunkhorst, Frank M. ;
Engel, Christoph ;
Bloos, Frank ;
Meier-Hellmann, Andreas ;
Ragaller, Max ;
Weiler, Norbert ;
Moerer, Onnen ;
Gruendling, Matthias ;
Oppert, Michael ;
Grond, Stefan ;
Olthoff, Derk ;
Jaschinski, Ulrich ;
John, Stefan ;
Rossaint, Rolf ;
Welte, Tobias ;
Schaefer, Martin ;
Kern, Peter ;
Kuhnt, Evelyn ;
Kiehntopf, Michael ;
Hartog, Christiane ;
Natanson, Charles ;
Loeffler, Markus ;
Reinhart, Konrad .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (02) :125-139
[5]   Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients [J].
Brunner, Richard ;
Kitzberger, Reinhard ;
Miehsler, Wolfgang ;
Herkner, Harald ;
Madl, Christian ;
Holzinger, Ulrike .
CRITICAL CARE MEDICINE, 2011, 39 (04) :659-664
[6]   Stress hyperglycaemia and increased risk of death after myocardial infarction in patients with and without diabetes: a systematic overview [J].
Capes, SE ;
Hunt, D ;
Malmberg, K ;
Gerstein, HC .
LANCET, 2000, 355 (9206) :773-778
[7]   Stress hyperglycemia and prognosis of stroke in nondiabetic and diabetic patients - A systematic overview [J].
Capes, SE ;
Hunt, D ;
Malmberg, K ;
Pathak, P ;
Gerstein, HC .
STROKE, 2001, 32 (10) :2426-2432
[8]   IMPLANTED ELECTROENZYMATIC GLUCOSE SENSORS [J].
CLARK, LC ;
DUGGAN, CA .
DIABETES CARE, 1982, 5 (03) :174-180
[9]   Glucose control and the inflammatory response [J].
Collier, Bryan ;
Dossett, Lesly A. ;
May, Addison K. ;
Diaz, Jose J. .
NUTRITION IN CLINICAL PRACTICE, 2008, 23 (01) :3-15
[10]   Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients [J].
Corstjens, Anouk M. ;
Ligtenberg, Jack J. M. ;
van der Horst, Iwan C. V. ;
Spanjersberg, Rob ;
Lind, Joline S. W. ;
Tulleken, Jaap E. ;
Meertens, John H. J. M. ;
Zijlstra, Jan G. .
CRITICAL CARE, 2006, 10 (05)