Performance of 8 x 8 Pixel LaBr3:Ce and Gd2SiO5:Ce Scintillator Arrays Coupled to a 64-Channel Multi-Anode PMT

被引:16
作者
Kurosawa, Shunsuke [1 ]
Kubo, Hidetoshi [1 ]
Hattori, Kaori [1 ]
Ida, Chihiro [1 ]
Iwaki, Satoru [1 ]
Kabuki, Shigeto [1 ]
Miuchi, Kentaro [1 ]
Nishimura, Hironobu [1 ]
Okada, Yoko [1 ]
Parker, Joseph D. [1 ]
Takada, Atsushi [2 ]
Takahashi, Michiaki [1 ]
Tanimori, Toru [1 ]
Ueno, Kazuki [1 ]
Yanagida, Yoshio [3 ]
机构
[1] Kyoto Univ, Grad Sch Sci, Dept Phys, Kyoto 6068502, Japan
[2] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2298510, Japan
[3] World Engn Syst, Kyoto 6078188, Japan
关键词
Array camera; Compton camera; GSO:Ce; LaBr3:Ce; scintillation detectors; RAY IMAGING DETECTOR; RADIATION-DAMAGE; COMPTON CAMERA; RESOLUTION; DESIGN; CRYSTALS; CHAMBER; TELESCOPE; TPC;
D O I
10.1109/TNS.2009.2034657
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a LaBr3: Ce scintillator array consisting of 8 x 8 pixels with a size of 5.8 mm x 5.8 mm x 15.0 mm, which serves as an absorber of scattered gamma rays with energies from 0.1 to 1 MeV in a Compton camera. The pixels were cut from two pieces of LaBr3: Ce crystal with a diameter of 38 mm and a length of 38 mm with full width at half-maximum (FWHM) energy resolutions of 4.1 +/- 0.1% and 3.0 +/- 0.1% at 356 and 662 keV, respectively, measured with a single anode photomultiplier tube (PMT). The crystal had the following volumetric uniformities: light outputs with a difference of 0.5% (standard deviation: SD) and energy resolutions with that of 2% (SD) at 356 keV. In contrast, for each pixel in the array, the average and SD FWHM energy resolutions over 64 pixels, measured with a single-anode PMT and a collimator, were 5.8 +/- 0.9% at 356 keV. The array was then coupled to a 64-channel multi-anode PMT (Hamamatsu H8500), the anode pitch of which was the same as the LaBr3: Ce pixel pitch of 6.1 mm. When the 64 anodes were read out from four channels in a resistor chain by the charge division method, the FWHM energy resolution of all 64 pixels was 7.0 +/- 0.5% at 662 keV, whereas that of the inner 6 x 6 pixels was 5.8 +/- 0.4% at 662 keV. In addition, we measured a Gd2SiO5 : Ce (GSO: Ce) scintillator array consisting of 8 x 8 pixels with a size of 5.9 mm x 5.9 mm x 13.0 mm to compare its performance with that of the LaBr3: Ce array. The FWHM energy resolution of all 64 GSO: Ce pixels was 10.8 +/- 0.3% at 662 keV. With these energy resolutions, FWHM angular resolutions of the Compton camera using the LaBr3: Ce and GSO: Ce arrays are expected to be 4.6 degrees and 5.3 degrees, respectively, at 662 keV.
引用
收藏
页码:3779 / 3788
页数:10
相关论文
共 71 条
[1]  
*3M, VIK ESR MSDS DAT SHE
[2]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]   SCINTILLATION CAMERA [J].
ANGER, HO .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) :27-33
[4]  
Bloser PF, 2006, IEEE NUCL SCI CONF R, P1500
[5]   Position Resolution in LaBr3 and LaCl3 Scintillators Using Position-Sensitive Photomultiplier Tubes [J].
Bloser, Peter F. ;
McConnell, Mark L. ;
Macri, John R. ;
Ryan, James M. ;
Baker, Justin J. .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :1204-1207
[6]   Performance characteristics of high resolution Compton telescopes [J].
Boggs, SE ;
Jean, P .
ASTRONOMY & ASTROPHYSICS, 2001, 376 (03) :1126-1134
[7]   The SIGMA/Granat telescope:: Calibration and data reduction [J].
Bouchet, L ;
Roques, JP ;
Ballet, J ;
Goldwurm, A ;
Paul, J .
ASTROPHYSICAL JOURNAL, 2001, 548 (02) :990-1009
[8]   A High Sensitivity Gamma Ray Imager (HiSGRI) Based on Wavelength-Shifting Fiber Readout of LaBr3 Scintillators [J].
Budden, Brent ;
Cherry, Michael L. ;
Case, Gary L. ;
Isbert, Joachim ;
Stewart, Michael .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :943-949
[9]  
CASE GL, 2005, P SPIE, V5898
[10]   Observations of Cygnus X-1 with the EXITE2 hard X-ray balloon payload [J].
Chou, Y ;
Bloser, PF ;
Grindlay, JE ;
Narita, T .
ASTROPHYSICAL JOURNAL, 2005, 618 (02) :856-865