An experimental study of air-water Taylor flow and mass transfer inside square microchannels

被引:141
作者
Yue, Jun [1 ,2 ]
Luo, Lingai [1 ]
Gonthier, Yves [1 ]
Chen, Guangwen [2 ]
Yuan, Quan [2 ]
机构
[1] Univ Savoie, LOCIE, F-73376 Savoie Technolac, Bourget Lac, France
[2] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian Natl Lab Clean Energy, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchannel; Taylor flow; Bubble; Hydrodynamics; Mass transfer; Multiphase reactors; LIQUID 2-PHASE FLOW; BUBBLE-TRAIN FLOW; MICROFABRICATED MULTIPHASE REACTORS; GAS-LIQUID; PRESSURE-DROP; LONG BUBBLES; POLYGONAL CAPILLARIES; DIRECT FLUORINATION; ELEMENTAL FLUORINE; FILM THICKNESS;
D O I
10.1016/j.ces.2009.05.026
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Flow and mass transfer properties under air-water Taylor flow have been investigated in two square microchannels with hydraulic diameters of 400 and 200 mu m. Experimental data on Taylor bubble velocity, pressure drop and liquid side volumetric mass transfer coefficient (k(L)a) have been presented. It was shown that the measured Taylor bubble velocity in square microchannels could be well interpreted based upon an approximate measurement of the liquid film profile therein. Then, the obtained two-phase frictional pressure drop values in both microchannels were found to be significantly higher than the predictions of the correlation proposed by Kreutzer et al. [2005b. Inertial and interfacial effects on pressure drop of Taylor flow in capillaries. A.I.Ch.E. journal 51, 2428-2440] when the liquid slug was very short, which can be explained by the inadequacy of their correlation to describe the excess pressure drop caused by the strong inner circulation in such short liquid slugs. An appropriate modification has been made to this correlation in order to improve its applicability in microchannels. Finally, the experimental (k(L)a) values in the microchannel with hydraulic diameter of 400 mu m were found to be in poor agreement with those predicted by the existing correlations proposed for capillaries with diameters of several millimeters. The observed deviation was mainly due to the fact that mass transfer experiments in this microchannel actually corresponded to the case of short film contact time and rather poor mixing between the liquid film and the liquid slug, which was not in accordance with mass transfer assumptions associated with these correlations. A new empirical correlation has been proposed to describe mass transfer data in this microchannel. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3697 / 3708
页数:12
相关论文
共 60 条
[1]   CFD and kinetic methods for mass transfer determination in a mesh microreactor [J].
Abdallah, Radwan ;
Magnico, Pierre ;
Fumey, Bruno ;
de Bellefon, Claude .
AICHE JOURNAL, 2006, 52 (06) :2230-2237
[2]   Hydrodynamics of Taylor flow in small channels: a review [J].
Angeli, P. ;
Gavriilidis, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (05) :737-751
[3]   Quick deposition of a fluid on the wall of a tube [J].
Aussillous, P ;
Quéré, D .
PHYSICS OF FLUIDS, 2000, 12 (10) :2367-2371
[4]   The role of gas bubbles and liquid slug lengths on mass transport in the Taylor flow through capillaries [J].
Bercic, G ;
Pintar, A .
CHEMICAL ENGINEERING SCIENCE, 1997, 52 (21-22) :3709-3719
[5]   THE MOTION OF LONG BUBBLES IN TUBES [J].
BRETHERTON, FP .
JOURNAL OF FLUID MECHANICS, 1961, 10 (02) :166-188
[6]   Elemental fluorine - Part 13. Gas-liquid thin film microreactors for selective direct fluorination [J].
Chambers, RD ;
Holling, D ;
Spink, RCH ;
Sandford, G .
LAB ON A CHIP, 2001, 1 (02) :132-137
[7]   Gas-Liquid Microreaction Technology: Recent Developments and Future Challenges [J].
Chen Guangwen ;
Yue Jun ;
Yuan Quan .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (05) :663-669
[9]   The effect of channel diameter on adiabatic two-phase flow characteristics in microchannels [J].
Chung, PMY ;
Kawaji, M .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2004, 30 (7-8) :735-761