Hypersensitivity reaction against patent blue during sentinel lymph node removal in three melanoma patients

被引:43
作者
Keller, Beat
Yawalkar, Nikhil
Pichler, Christiane
Braathen, Lasse R.
Hunger, Robert E. [1 ]
机构
[1] Univ Bern, Inselspital, Dept Dermatol, CH-3010 Bern, Switzerland
[2] Univ Bern, Inselspital, Clin Rheumatol & Clin Immunol Allergol, Div Allergol, CH-3010 Bern, Switzerland
关键词
sentinel lymph node dissection; melanoma; allergy; patent blue; hypersensitivity reaction;
D O I
10.1016/j.amjsurg.2006.03.013
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: In order to identify the sentinel lymph node (SLN) in melanoma patients intradermal injection of a radiocolloid tracer and a blue dye are commonly used. Life-threatening side effects such as allergic reactions to the injected dye have been described. We report 3 cases with systemic allergic reactions. Methods: Three patients suffering from systemic reactions such as hypotension and rash during SLN biopsy were tested for sensitisation against patent blue and methylene blue with skin prick, scratch, and intradermal test. Results: All 3 patients showed positive skin tests to patent blue confirming allergic reaction to the injected dye. In addition, all patients showed positive skin tests with methylene blue indicating immunologic cross-reactivity between patent blue and methylene blue. Conclusions: Although allergic reactions to blue dye during SLN biopsy are rare, they may be life threatening. It is important that the attending anesthetist is aware of this. (c) 2007 Excerpta Medica Inc. All rights reserved.
引用
收藏
页码:122 / 124
页数:3
相关论文
共 19 条
[1]   GAMMA-PROBE GUIDED LOCALIZATION OF LYMPH-NODES [J].
ALEX, JC ;
KRAG, DN .
SURGICAL ONCOLOGY-OXFORD, 1993, 2 (03) :137-143
[2]   CASE-REPORT - SERIOUS ADVERSE REACTION TO PATENT BLUE VIOLET AT LYMPHOGRAPHY [J].
BARBER, CJ .
CLINICAL RADIOLOGY, 1989, 40 (06) :631-631
[3]  
CABANAS RM, 1977, CANCER, V39, P456, DOI 10.1002/1097-0142(197702)39:2<456::AID-CNCR2820390214>3.0.CO
[4]  
2-I
[5]  
HIETALA SO, 1977, LYMPHOLOGY, V10, P158
[6]   ANAPHYLAXIS FROM ALPHAZURINE 2G DURING LYMPHOGRAPHY [J].
KOPP, WL .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 198 (06) :668-&
[7]   The sentinel node in breast cancer - A multicenter validation study [J].
Krag, D ;
Weaver, D ;
Ashikaga, T ;
Moffat, F ;
Klimberg, VS ;
Shriver, C ;
Feldman, S ;
Kusminsky, R ;
Gadd, M ;
Kuhn, J ;
Harlow, S ;
Beitsch, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (14) :941-946
[8]   Adverse reactions to isosulfan blue during selective sentinel lymph node dissection in melanoma [J].
Leong, SPL ;
Donegan, E ;
Heffermon, W ;
Dean, S ;
Katz, JA .
ANNALS OF SURGICAL ONCOLOGY, 2000, 7 (05) :361-366
[9]   Sentinel node biopsy for early-stage melanoma - Accuracy and morbidity in MSLT-I, an international multicenter trial [J].
Morton, DL ;
Cochran, AJ ;
Thompson, JF ;
Elashoff, R ;
Essner, R ;
Glass, EC ;
Mozzillo, N ;
Nieweg, OE ;
Roses, DF ;
Hoekstra, HJ ;
Karakousis, CP ;
Reintgen, DS ;
Coventry, BJ ;
Wang, HJ .
ANNALS OF SURGERY, 2005, 242 (03) :302-313
[10]  
MORTON DL, 1992, ARCH SURG-CHICAGO, V127, P392