Wearable Devices Suitable for Monitoring Twenty Four Hour Heart Rate Variability in Military Populations

被引:89
作者
Hinde, Katrina [1 ]
White, Graham [1 ]
Armstrong, Nicola [1 ]
机构
[1] Def & Sci Technol Lab, Human & Social Sci Grp, Salisbury SP4 0JQ, Wilts, England
关键词
wearable technology; reliability; validity; occupational groups; long term; heart rate variability; PRESSURE;
D O I
10.3390/s21041061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart rate variability (HRV) measurements provide information on the autonomic nervous system and the balance between parasympathetic and sympathetic activity. A high HRV can be advantageous, reflecting the ability of the autonomic nervous system to adapt, whereas a low HRV can be indicative of fatigue, overtraining or health issues. There has been a surge in wearable devices that claim to measure HRV. Some of these include spot measurements, whilst others only record during periods of rest and/or sleep. Few are capable of continuously measuring HRV (>= 24 h). We undertook a narrative review of the literature with the aim to determine which currently available wearable devices are capable of measuring continuous, precise HRV measures. The review also aims to evaluate which devices would be suitable in a field setting specific to military populations. The Polar H10 appears to be the most accurate wearable device when compared to criterion measures and even appears to supersede traditional methods during exercise. However, currently, the H10 must be paired with a watch to enable the raw data to be extracted for HRV analysis if users need to avoid using an app (for security or data ownership reasons) which incurs additional cost.
引用
收藏
页码:1 / 20
页数:19
相关论文
共 53 条
[1]  
AHMAD S, 2009, J STRENGTH COND RES, V4, pE6642, DOI DOI 10.1371/JOURNAL.PONE.0006642
[2]  
AKINTOLA AA, 2016, INT ARCH OCC ENV HEA, V7, P391, DOI DOI 10.3389/FPHYS.2016.00391
[3]  
[Anonymous], BITTIUM BITTIUM FARO
[4]  
[Anonymous], EQUIVITAL EQ LIFEMON
[5]  
[Anonymous], CAMNTECH ACTIHEART 5
[6]   Evaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis [J].
Barrios, Liliana ;
Oldrati, Pietro ;
Santini, Silvia ;
Lutterotti, Andreas .
PROCEEDINGS OF THE 13TH EAI INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE (PERVASIVEHEALTH 2019), 2019, :251-261
[7]  
BENT B, 2020, PHYSIOL MEAS, V3, P18, DOI DOI 10.1038/S41746-020-0226-6
[8]  
BENVENUTI SM, 2015, SCAND J MED SCI SPOR, V106, P28, DOI DOI 10.1016/J.BIOPSYCHO.2014.11.017
[9]   The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance [J].
Billman, George E. .
FRONTIERS IN PHYSIOLOGY, 2013, 4
[10]  
Bogdny T., 2016, Magyar Sporttudomnyi Szem, V17, P5, DOI DOI 10.1249/MSS.0000000000001658