Cervical pedicle screws versus lateral mass screws - Anatomic feasibility and biomechanical comparison

被引:371
作者
Jones, EL [1 ]
Heller, JG [1 ]
Silcox, DH [1 ]
Hutton, WC [1 ]
机构
[1] EMORY UNIV,SCH MED,EMORY SPINE CTR,DEPT ORTHOPAED SURG,DECATUR,GA 30033
关键词
anatomy; biomechanical; cervical; dimension; lateral mass; pedicle;
D O I
10.1097/00007632-199705010-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Biomechanical comparison of the pullout strengths of lateral mass and pedicle screws in the human cervical spine. Measurements of pedicle dimensions and orientation were compiled. Objectives. To determine if transpedicular screws provide greater pull-out resistance than lateral mass screws and to investigate the anatomic feasibility of pedicle screw insertion. Summary of Background Data. Cervical pedicle screws have been reported in limited clinical and biomechanical studies, and some quantitative cervical pedicle anatomy has been reported. No direct biomechanical comparisons have been made between lateral mass and pedicle screws. Methods. Fifty-six fresh disarticulated human vertebrae (C2-C7) were evaluated with computed tomography to determine morphometry and vertebral body bone density. Lateral mass and pedicle screws were randomized to left versus right. A 3.5-mm cortical screw was used for both techniques, unless a pedicle was narrower than 5.0 mm; then a 2.7-mm cortical screw was used instead. Pedicle wall violations were recorded, Screws were subjected to a uniaxial load to failure. Mean pedicle height, width, and angle with respect to the vertebral midline were tabulated for each level. Results. The mean load-to-failure was 677 N for the cervical pedicle screws and 355 N for the lateral mass screws. No significant correlations for either screw type were found between pull-out strength and bone density, screw length, or vertebral level. Pedicle and lateral mass dimensions were highly variable and not predictive of pull-out strength. Seven (13%) minor pedicle wall violations were observed. Conclusions. Cervical pedicle screws demonstrated a significantly higher resistance to pull-out forces than did lateral mass screws. The variability in pedicle morphometry and orientation requires careful preoperative assessment to determine the suitability of pedicle screw insertion.
引用
收藏
页码:977 / 982
页数:6
相关论文
共 21 条
[1]  
ABUMI K, 1995, ORTHOP T, V19, P380
[2]   ANATOMIC CONSIDERATIONS FOR PLATE-SCREW FIXATION OF THE CERVICAL-SPINE [J].
AN, HS ;
GORDIN, R ;
RENNER, K .
SPINE, 1991, 16 (10) :S548-S551
[3]   POSTERIOR STABILIZATION OF CERVICAL-SPINE FRACTURES AND SUBLUXATIONS USING PLATES AND SCREWS [J].
COOPER, PR ;
COHEN, A ;
ROSIELLO, A ;
KOSLOW, M .
NEUROSURGERY, 1988, 23 (03) :300-306
[4]  
EBRAHEIM NA, 1995, J SPINAL DISORD, V8, P111
[5]  
FEHLING SMG, 1992, 20 ANN M CERV SPIN R
[6]   POSTERIOR PLATING OF THE CERVICAL-SPINE - A BIOMECHANICAL COMPARISON OF DIFFERENT POSTERIOR FUSION TECHNIQUES [J].
GILL, K ;
PASCHAL, S ;
CORIN, J ;
ASHMAN, R ;
BUCHOLZ, RW .
SPINE, 1988, 13 (07) :813-816
[7]   Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance [J].
Heller, JG ;
Estes, BT ;
Zaouali, M ;
Diop, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1315-1321
[8]   COMPLICATIONS OF POSTERIOR CERVICAL PLATING [J].
HELLER, JG ;
SILCOX, DH ;
SUTTERLIN, CE .
SPINE, 1995, 20 (22) :2442-2448
[9]   ANATOMIC COMPARISON OF THE ROY-CAMILLE AND MAGERL TECHNIQUES FOR SCREW PLACEMENT IN THE LOWER CERVICAL-SPINE [J].
HELLER, JG ;
CARLSON, GD ;
ABITBOL, JJ ;
GARFIN, SR .
SPINE, 1991, 16 (10) :S552-S557
[10]  
Heller JG, 1991, ADULT SPINE PRINCIPL, P1219