Validation of analytical formulae for the efficiency calibration of gamma detectors used in laboratory and in-situ measurements

被引:22
作者
Abbas, Mahmoud I. [1 ]
机构
[1] Univ Alexandria, Fac Sci, Dept Phys, Alexandria 21121, Egypt
关键词
in-situ gamma spectroscopy systems; parallelepiped detector; extended source and full-energy peak efficiency;
D O I
10.1016/j.apradiso.2006.05.017
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Direct analytical formulae for the efficiency calibration of gamma (scintillation and semiconductor) detectors using an arbitrarily positioned radiating point source are extended to include sources with volumetric shapes. The attenuation of photons by the source itself (self-absorption) is determined by calculating the photon path length through the source material. The theoretical and the published experimental efficiency values are in good agreement. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1661 / 1664
页数:4
相关论文
共 18 条
[1]   Calculation of relative full-energy peak efficiencies of well-type detectors [J].
Abbas, MI ;
Selim, YS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3) :651-657
[2]   Analytical formulae for well-type NaI (Tl) and HPGe detectors efficiency computation [J].
Abbas, MI .
APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) :245-252
[3]   HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions [J].
Abbas, MI .
APPLIED RADIATION AND ISOTOPES, 2001, 54 (05) :761-768
[4]   A direct mathematical method to calculate the efficiencies of a parallelepiped detector for an arbitrarily positioned point source [J].
Abbas, MI .
RADIATION PHYSICS AND CHEMISTRY, 2001, 60 (1-2) :3-9
[5]   Three types of photon detectors for in situ measurements [J].
Helmer, RG ;
Gehrke, RJ ;
Carpenter, MV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :826-831
[6]  
Hubbell J. H., 1995, 5632 NISTIR
[7]   DETECTOR-EFFICIENCY CALCULATION BASED ON POINT-SOURCE MEASUREMENT [J].
LIPPERT, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08) :1097-1103
[8]   EXTSANGLE - AN EXTENSION OF THE EFFICIENCY CONVERSION PROGRAM SOLANG TO SOURCES WITH A DIAMETER LARGER THAN THAT OF THE GE-DETECTOR [J].
MIHALJEVIC, N ;
JOVANOVIC, S ;
DECORTE, F ;
SMODIS, B ;
JACIMOVIC, R ;
MEDIN, G ;
DEWISPELAERE, A ;
VUKOTIC, P ;
STEGNAR, P .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (01) :209-218
[9]   CALCULATION OF THE ABSOLUTE PEAK EFFICIENCY OF GAMMA-RAY DETECTORS FOR DIFFERENT COUNTING GEOMETRIES [J].
MOENS, L ;
DEDONDER, J ;
LIN, X ;
DECORTE, F ;
DEWISPELAERE, A ;
SIMONITS, A ;
HOSTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3) :451-472
[10]   CALCULATION OF THE PEAK EFFICIENCY OF HIGH-PURITY GERMANIUM DETECTORS [J].
MOENS, L ;
HOSTE, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08) :1085-1095