Impact of dust loading on long term portable air cleaner performance

被引:39
作者
Zuraimi, M. S. [1 ]
Vuotari, M. [1 ]
Nilsson, G. [1 ]
Magee, R. [1 ]
Kemery, B. [1 ]
Alliston, C. [2 ]
机构
[1] Natl Res Council Canada, Intelligent Bldg Operat, Construct Portfolio, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
[2] Environm & Climate Change Canada, Air Qual Res Div, Atmospher Sci & Technol Directorate, 335 River Rd S, Ottawa, ON K1A 0H3, Canada
关键词
Portable air cleaners; Long term performance; HEPA; Electrostatic precipitators; Particles; Ozone; INDOOR; FILTRATION; VENTILATION; REMOVAL; ENERGY; GENERATION; PRESSURE; QUALITY; FILTERS;
D O I
10.1016/j.buildenv.2016.11.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although there has been many studies conducted on the initial performance of portable air cleaners (PACs), there is little research on the evaluation of their long term performance. This paper quantifies the effects of particle loading on PAC particle removal, airflow rate, power consumption and ozone emissions for a HEPA- and electrostatic precipitator (ESP) - based PAC. Ozone emission rates decreased in a linear fashion for the ESP-based PAC suggesting dust masking on the unit's discharge electrode. Performance in terms of particle clean air delivery rates (CADR), airflow rates and power consumption reduced for both units as dust was loaded up to the filter's half-life. For the HEPA based PAC, particle CADR reductions are due to reduced airflow rates. As a consequence, the particle single pass efficiencies (SPEs) grew indicating dust accumulation on the filter. This phenomenon is not observed on the ESP-based PAC where both particle CADR as well as SPE reduced upon dust loading. This study demonstrates the importance of regular filter maintenance for PAC to ensure optimal performance. (C) 2016 Published by Elsevier Ltd.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 129 ASHRAE
[2]  
[Anonymous], 2006, AC12006 AHAM ANSI
[3]  
[Anonymous], TEST METHOD ASSESS L
[4]  
[Anonymous], 311 GOV CAN CLEAN AG
[5]  
[Anonymous], CMHC TECHN SER
[6]  
[Anonymous], 1360RP ASHRAE
[7]  
[Anonymous], E47100 ASTM
[8]  
ASHRAE, 2012, 522 ASHRAE
[9]   Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness [J].
Barn, Prabjit ;
Larson, Timothy ;
Noullett, Melanie ;
Kennedy, Susan ;
Copes, Ray ;
Brauer, Michael .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2008, 18 (05) :503-511
[10]   Long duration tests of room air filters in cigarette smokers' homes [J].
Batterman, S ;
Godwin, C ;
Jia, CR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (18) :7260-7268