Optimal grid point selection for improved non-rigid medical image registration

被引:1
|
作者
Fookes, C [1 ]
Maeder, A [1 ]
机构
[1] Queensland Univ Technol, Sch Elect Elect & Syst Engn, Brisbane, Qld 4001, Australia
关键词
non-rigid image registration; block matching; Markov Chain; Monte Carlo;
D O I
10.1117/12.536828
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Non-rigid image registration is an essential tool required for overcoming the inherent local anatomical variations that exist between images acquired from different individuals or atlases, among others. This type of registration defines a deformation field that gives a translation or mapping for every pixel in the image. One popular local approach for estimating this deformation field, known as block matching, is where a grid of control points are defined on an image and are each taken as the centre of a small window. These windows are then translated in the second image to maximise a local similarity criterion. This generates two corresponding sets of control points for the two images, yielding a sparse deformation field. This sparse field can then be propagated to the entire image using methods such as the thin-plate spline warp or simple Gaussian convolution. Previous block matching procedures all utilise uniformly distributed grid points. This results in the generation of a sparse deformation field containing displacement estimates at uniformly spaced locations. This neglects to make use of the evidence that block matching results are dependent on the amount of local information content. That is, results are better in regions of high information when compared to regions of low information. Consequently, this paper presents a solution to this drawback by proposing the use of a Reversible Jump Markov Chain Monte Carlo (RJMCMC) statistical procedure to optimally select grid points of interest. These grid points have a greater concentration in regions of high information and a lower concentration in regions of small information. Results show that non-rigid registration can by improved by using optimally selected grid points of interest.
引用
收藏
页码:1187 / 1194
页数:8
相关论文
共 50 条
  • [1] Rigid and non-rigid medical image registration methods
    Dhawan, Atam P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 200 - 219
  • [2] Non-rigid medical image registration based on improved Demons algorithm
    Zhang, Hong-Ying
    Zhang, Jia-Wan
    Sun, Ji-Zhou
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2007, 15 (01): : 145 - 150
  • [3] An improved non-rigid image registration approach
    He K.
    Wei Y.
    Wang Y.
    Huang W.-R.
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2019, 41 (07): : 955 - 960
  • [4] Medical image non-rigid registration based on improved finite element method
    Xu, Shengzhou
    Hu, Huaifei
    Sensors and Transducers, 2013, 161 (12): : 568 - 573
  • [5] Medical image non-rigid registration method guided by a matched feature point pair
    Wang, Zhen-Song
    Liu, Xiao-Yun
    Chen, Wu-Fan
    Dianzi Keji Daxue Xuebao/Journal of the University of Electronic Science and Technology of China, 2012, 41 (03): : 471 - 476
  • [6] REGULARIZED SURFACE AND POINT LANDMARKS BASED EFFICIENT NON-RIGID MEDICAL IMAGE REGISTRATION
    Shah, Said Khalid
    COMPUTING AND INFORMATICS, 2018, 37 (01) : 244 - 268
  • [7] A non-rigid medical image registration method based on improved linear elastic model
    Lu, Xiaoqi
    Ma, Hongli
    Zhang, Baohua
    OPTIK, 2012, 123 (20): : 1867 - 1873
  • [8] AN IMPROVED METHOD OF "DEMONS" NON-RIGID IMAGE REGISTRATION ALGORITHM
    Lin, Xiangbo
    Qiu, Tianshuang
    Nicolier, Frederic
    Ruan, Su
    ICSP: 2008 9TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-5, PROCEEDINGS, 2008, : 1091 - +
  • [9] Non-rigid registration method of the medical image based on the LBM
    Tong, Ming
    Cao, Yang
    He, Mengyue
    Zhang, Jianlong
    Tong, M. (mtong@xidian.edu.cn), 2013, Science Press (40): : 6 - 13
  • [10] Multi-modality non-rigid medical image registration
    Rogelj, Peter
    Kovacic, Stanislav
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2007, 74 (05): : 309 - 314