Wavelength-modulation spectroscopy near 2.5 μm for H2O and temperature in high-pressure and -temperature gases

被引:39
作者
Goldenstein, C. S. [1 ]
Spearrin, R. M. [1 ]
Jeffries, J. B. [1 ]
Hanson, R. K. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, High Temp Gasdynam Lab, Stanford, CA 94305 USA
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2014年 / 116卷 / 03期
关键词
DIODE-LASER MEASUREMENTS; SPECTRUM LINE-PROFILES; 2ND-HARMONIC DETECTION; EXTERNAL-CAVITY; WATER-VAPOR; PARAMETERS; SENSOR; DOPPLER; TRANSITIONS; CO2;
D O I
10.1007/s00340-013-5754-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design and validation of a tunable diode laser (TDL) sensor for temperature and H2O in high-pressure and -temperature gases are presented. High-fidelity measurements are enabled through the use of: (1) strong H2O fundamental-band absorption near 2.5 mu m, (2) calibration-free first-harmonic-normalized wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f/1f), (3) an experimentally derived and validated spectroscopic database, and (4) a new approach to selecting the optimal wavelength and modulation depth of each laser. This sensor uses two TDLs near 2,474 and 2,482 nm that were fiber coupled in free space and frequency multiplexed to enable measurements along a single line-of-sight. The lasers were modulated at 35 and 45.5 kHz, respectively, to achieve a sensor bandwidth of 4.5 kHz. This sensor was validated in a shock tube at temperatures and pressures ranging from 1,000 to 2,700 K and 8 to 50 bar. There the sensor resolved transients and recovered the known steady-state temperature and H2O mole fraction with a precision of 3.2 and 2.6 % RMS, respectively.
引用
收藏
页码:705 / 716
页数:12
相关论文
共 40 条
[1]   Determining the optimum wavelength pairs to use for molecular absorption thermometry based on the continuous-spectral lower-state energy [J].
An, Xinliang ;
Caswell, Andrew W. ;
Lipor, John J. ;
Sanders, Scott T. .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2011, 112 (14) :2355-2362
[2]   SPECTRUM LINE PROFILES - VOIGT FUNCTION [J].
ARMSTRONG, BH .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1967, 7 (01) :61-+
[3]  
Ben-Dor G., 2001, 2001 HDB SHOCK WAVES
[4]  
Bevington P. R., 2002, Data reduction and error analysis for the physical sciences
[5]   ATMOSPHERIC-PRESSURE MONITORING OF TRACE GASES USING TUNABLE DIODE-LASERS [J].
CASSIDY, DT ;
REID, J .
APPLIED OPTICS, 1982, 21 (07) :1185-1190
[6]   TRACE GAS-DETECTION WITH SHORT-EXTERNAL-CAVITY INGAASP DIODE-LASER TRANSMITTER MODULES OPERATING AT 1.58 MU-M [J].
CASSIDY, DT ;
BONNELL, LJ .
APPLIED OPTICS, 1988, 27 (13) :2688-2693
[7]   Measurements of multiple gas parameters in a pulsed-detonation combustor using time-division-multiplexed Fourier-domain mode-locked lasers [J].
Caswell, Andrew W. ;
Roy, Sukesh ;
An, Xinliang ;
Sanders, Scott T. ;
Schauer, Frederick R. ;
Gord, James R. .
APPLIED OPTICS, 2013, 52 (12) :2893-2904
[8]   THE EFFECT OF COLLISIONS UPON THE DOPPLER WIDTH OF SPECTRAL LINES [J].
DICKE, RH .
PHYSICAL REVIEW, 1953, 89 (02) :472-473
[9]   Measurements of CO2 concentration and temperature at high pressures using 1f-normalized wavelength modulation spectroscopy with second harmonic detection near 2.7 μm [J].
Farooq, A. ;
Jeffries, J. B. ;
Hanson, R. K. .
APPLIED OPTICS, 2009, 48 (35) :6740-6753
[10]   Digital, phase-sensitive detection for in situ diode-laser spectroscopy under rapidly changing transmission conditions [J].
Fernholz, T ;
Teichert, H ;
Ebert, V .
APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3) :229-236