CTF determination and correction in electron cryotomography

被引:139
作者
Fernandez, J. J. [1 ]
Li, S.
Crowther, R. A.
机构
[1] Univ Almeria, Dept Comp Architecture & Elect, Almeria 04120, Spain
[2] MRC, Mol Biol Lab, Cambridge CB2 2QH, England
基金
英国医学研究理事会;
关键词
contrast transfer function; CTF; electron cryotomography; image processing algorithms; image reconstruction;
D O I
10.1016/j.ultramic.2006.02.004
中图分类号
TH742 [显微镜];
学科分类号
摘要
Electron cryotomography (cryoET) has the potential to elucidate the structure of complex biological specimens at molecular resolution but technical and computational improvements are still needed. This work addresses the determination and correction of the contrast transfer function (CTF) of the electron microscope in cryoET. Our approach to CTF detection and defocus determination depends on strip-based periodogram averaging, extended throughout the tilt series to overcome the low contrast conditions found in cryoET. A method for CTF correction that deals with the defocus gradient in images of tilted specimens is also proposed. These approaches to CTF determination and correction have been applied here to several examples of cryoET of pleomorphic specimens and of single particles. CTF correction is essential for improving the resolution, particularly in those studies that combine cryoET with single particle averaging techniques. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:587 / 596
页数:10
相关论文
共 37 条
  • [1] Nuclear pore complex structure and dynamics revealed by cryoelectron tomography
    Beck, M
    Förster, F
    Ecke, M
    Plitzko, JM
    Melchior, F
    Gerisch, G
    Baumeister, W
    Medalia, O
    [J]. SCIENCE, 2004, 306 (5700) : 1387 - 1390
  • [2] Bottcher B, 1996, STRUCTURE, V4, P387
  • [3] Determination of the fold of the core protein of hepatitis B virus ky electron cryomicroscopy
    Bottcher, B
    Wynne, SA
    Crowther, RA
    [J]. NATURE, 1997, 386 (6620) : 88 - 91
  • [4] The yeast spindle pole body is assembled around a central crystal of Spc42p
    Bullitt, E
    Rout, MP
    Kilmartin, JV
    Akey, CW
    [J]. CELL, 1997, 89 (07) : 1077 - 1086
  • [5] Cryo-electron tomography of vaccinia virus
    Cyrklaff, M
    Risco, C
    Fernández, JJ
    Jiménez, MV
    Estéban, M
    Baumeister, W
    Carrascosa, JL
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (08) : 2772 - 2777
  • [6] Correction of high-resolution data for curvature of the Ewald sphere
    DeRosier, DJ
    [J]. ULTRAMICROSCOPY, 2000, 81 (02) : 83 - 98
  • [7] DIERCKX P., 1993, Monographs on Numerical Analysis
  • [8] TOWARDS AUTOMATIC ELECTRON TOMOGRAPHY
    DIERKSEN, K
    TYPKE, D
    HEGERL, R
    KOSTER, AJ
    BAUMEISTER, W
    [J]. ULTRAMICROSCOPY, 1992, 40 (01) : 71 - 87
  • [10] An improved algorithm for anisotropic nonlinear diffusion for denoising cryo-tomograms
    Fernández, JJ
    Li, S
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2003, 144 (1-2) : 152 - 161