Effect of vapor-injection technique on the performance of a cascade heat pump water heater

被引:28
|
作者
Roh, Chul Woo [1 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Sch Mech & Aerosp Engn, Div WCU Multiscale Mech Design, Seoul 151744, South Korea
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2014年 / 38卷
关键词
Cascade; Heat pump; Vapor injection; R404A; Water heater; REFRIGERANT INJECTION; SCROLL COMPRESSOR; SYSTEM; R410A;
D O I
10.1016/j.ijrefrig.2013.09.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we applied a vapor-injection (VI) technique in a cascade heat pump system. The VI was applied to both upper and lower stage cycles. Test results showed that heating and cooling capacities increased by using the VI technique (12% and 6%, respectively); however, the system COP decreased (6.6% at the injection ratio of 16.7%). The cascade system which has a small compression rate and a cascade condenser, cannot fully utilize the Vi's advantages to improve the system COP. However, the VI is effective for the system reliability and capacity improvement. We also found that the VI in the upper and lower stage cycles had different effect on overall cycle operating characteristic. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 50 条
  • [31] Review on the two-stage vapor injection heat pump with a flash tank
    Ceylan, Havva
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2023, 48
  • [32] THERMAL PERFORMANCE ANALYSIS AND OPTIMIZATION OF SOLAR ASSISTED HEAT PUMP WATER HEATER
    Kokila, R. N.
    Rajakumar, S.
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 2416 - +
  • [33] Investigation of the heat pump water heater using economizer vapor injection system and mixture of R22/R600a
    Cao Feng
    Wang Kai
    Wang Shouguo
    Xing Ziwen
    Shu Pencheng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (03): : 509 - 514
  • [34] Theoretical analysis of the impacts of refrigerant leakage on the performance of a flash tank vapor injection heat pump
    Chen, Guangming
    Fang, Jiahao
    Li, Zetian
    Zhang, Shaozhi
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 147 : 10 - 19
  • [35] Performance analysis of vapor injection heat pump system for electric vehicle in cold startup condition
    Choi, Young Uk
    Kim, Mo Se
    Kim, Gwi Taek
    Kim, Minsung
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 80 : 24 - 36
  • [36] A CASCADE HEAT PUMP FOR WATER HEATING
    Cleland, Don J.
    Cavill, John P.
    Johnson, Dick
    4TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2016, : 96 - 103
  • [37] Performance Research on Heating Performance of Battery Thermal Management Coupled with the Vapor Injection Heat Pump Air Conditioning
    Yuan, Weijian
    Guo, Yun
    Zhang, Yunshen
    WORLD ELECTRIC VEHICLE JOURNAL, 2024, 15 (01):
  • [38] Seeking a new throttle to substitute the thermostatic expansion valve in vapor-injection process for an air-source heat pump: An experimental study
    Wang, Jijin
    Qv, Dehu
    Ni, Long
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 54
  • [39] Experimental performance of a vapor-injection CO2 heat pump system for electric vehicles in-30?C to 50?C range
    Yang, Tianyang
    Zou, Huiming
    Tang, Mingsheng
    Tian, Changqing
    Yan, Yuying
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [40] Performance characteristics of a two-stage CO2 heat pump water heater adopting a sub-cooler vapor injection cycle at various operating conditions
    Baek, Changhyun
    Heo, Jaehyeok
    Jung, Jongho
    Cho, Honghyun
    Kim, Yongchan
    ENERGY, 2014, 77 : 570 - 578