Effect of vapor-injection technique on the performance of a cascade heat pump water heater

被引:28
|
作者
Roh, Chul Woo [1 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Sch Mech & Aerosp Engn, Div WCU Multiscale Mech Design, Seoul 151744, South Korea
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2014年 / 38卷
关键词
Cascade; Heat pump; Vapor injection; R404A; Water heater; REFRIGERANT INJECTION; SCROLL COMPRESSOR; SYSTEM; R410A;
D O I
10.1016/j.ijrefrig.2013.09.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we applied a vapor-injection (VI) technique in a cascade heat pump system. The VI was applied to both upper and lower stage cycles. Test results showed that heating and cooling capacities increased by using the VI technique (12% and 6%, respectively); however, the system COP decreased (6.6% at the injection ratio of 16.7%). The cascade system which has a small compression rate and a cascade condenser, cannot fully utilize the Vi's advantages to improve the system COP. However, the VI is effective for the system reliability and capacity improvement. We also found that the VI in the upper and lower stage cycles had different effect on overall cycle operating characteristic. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 50 条
  • [1] A novel testing and theoretical approach for air-source heat-pump water heater with flash tank vapor-injection
    Liu, Xianglong
    Guang, Hu
    Zhi, Zeng
    Ping, Wang
    Zeng, Liping
    Li, Xiaohua
    ENGINEERING RESEARCH EXPRESS, 2022, 4 (04):
  • [2] Experimental investigation on the heating performance of a R410A vapor-injection heat pump of an electric bus in cold regions
    Guo, Yang
    Guo, Junfeng
    Yang, Wei
    Zhao, Pengju
    Zhou, Yonggui
    Deng, Rongbin
    Jin, Zunlong
    APPLIED THERMAL ENGINEERING, 2023, 222
  • [3] Effects of intermediate pressure on the heating performance of a heat pump system using R410A vapor-injection technique
    Roh, Chul Woo
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (08): : 1911 - 1921
  • [4] A STUDY OF THE OPTIMUM INJECTION RATIO OF A HEAT PUMP SYSTEM USING VAPOR-INJECTION TECHNIQUE
    Ha, J. H.
    Roh, C. W.
    Jeong, H. J.
    Kim, M. S.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1665 - +
  • [5] Performance analysis of an R290 vapor-injection heat pump system for electric vehicles in cold regions
    Yang, Yunchun
    Shao, Wencong
    Yang, Tianyang
    Zou, Huiming
    Tian, Changqing
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2024, 67 (12) : 3673 - 3681
  • [6] Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 : 22 - 34
  • [7] Performance analysis of vapor-injection heat pump based on PVT collector/evaporator
    Shou C.
    Yao J.
    Zheng S.
    Peng H.
    Zhao Y.
    Dai Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (06): : 138 - 144
  • [8] Simulation Study on the Performance of an Enhanced Vapor-Injection Heat-Pump Drying System
    Dong, Suiju
    Liu, Yin
    Meng, Zhaofeng
    Zhai, Saina
    Hu, Ke
    Zhang, Fan
    Zhou, Dong
    ENERGIES, 2022, 15 (24)
  • [9] Thermodynamic analysis of a modified vapor-injection heat pump cycle using an ejector
    Zhao, Yang
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 137 - 147
  • [10] Study on performance of a heat pump water heater using suction stream liquid injection
    Cao Feng
    Fei Jiyou
    Xing Ziwen
    Li Liansheng
    APPLIED THERMAL ENGINEERING, 2009, 29 (14-15) : 2942 - 2948