Vectorcardiogram synthesized from the 12-lead electrocardiogram to image ischemia

被引:24
|
作者
Strauss, David G. [1 ,2 ,3 ]
Olson, Charles W. [4 ]
Wu, Katherine C. [2 ]
Heiberg, Einar [1 ]
Persson, Eva [1 ]
Selvester, Ronald H. [5 ]
Pahlm, Olle [1 ]
Arheden, Hakan [1 ]
机构
[1] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[2] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD USA
[3] Duke Univ, Sch Med, Durham, NC USA
[4] ECG TECH Corp, Huntington Stn, NY USA
[5] Mem Hosp, Res Ctr, Long Beach, CA USA
关键词
Electrocardiography; Imaging; Ischemia; Scintigraphy; ACUTE MYOCARDIAL-INFARCTION; ST-SEGMENT DEVIATION; LONG-AXIS ORIENTATION; CORONARY ANGIOPLASTY; RISK; SIZE; CARDIOLOGIST; REPERFUSION; HEART;
D O I
10.1016/j.jelectrocard.2008.12.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Knowledge of the location and size of ischemic myocardium at risk for infarction Could impact prehospital patient triage and reperfusion therapy. The 12-lead electrocardiogram (ECG) can roughly estimate ischemia size; however, individual precordial ECG leads are at different distances from the left ventricle (LV) and certain LV walls have greater effects on the ECG. Vectorcardiographic corrected orthogonal lead systems can display the magnitude and direction of the ST-segment "injury current" vector in 3-dimensional space. We assessed whether the vectorcardiographic ST-vector direction and magnitude derived from the ECG by the inverse-Dower method can estimate the location and size of ischemia. Methods and Results: Thirty-two patients underwent elective coronary angioplasty with control and 5-minute balloon-occlusion ECG and sestamibi injection followed by single photon emission computed tomography (SPECT). The ST-vector direction derived from the inverse-Dower method was projected to an LV model with normal coronary artery anatomy. The graphical display of ST-vector location Could discriminate among occlusions of the different coronaries. The ST-vector located ischemia within the SPECT defect in 75% (24/32) of all patients and 96% (24/25) of patients with ischemia in more than 12% of the LV. ST-vector magnitude had a Spearman correlation of r = 0.68 (P < .0001) with SPECT ischemia size. Conclusions: The 3-dimensional ST vector derived from the ECG can be graphically projected onto an LV model to localize ischemia, and ST-vector magnitude correlates with ischemia size. Further study is warranted to assess the ability of vectorcardiographic imaging to risk-stratify and provide decision-support for patients with acute myocardial infarction. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [11] Synthesis of the 12-Lead Electrocardiogram From Differential Leads
    Trobec, Roman
    Tomasic, Ivan
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 615 - 621
  • [12] The 12-lead electrocardiogram in supraventricular tachycardia
    Kumar, Uday N.
    Rao, Rajni K.
    Scheinman, Melvin M.
    CARDIOLOGY CLINICS, 2006, 24 (03) : 427 - +
  • [13] THE VALUE OF THE PREVIOUS 12-LEAD ELECTROCARDIOGRAM
    NIKOLIC, G
    HEART & LUNG, 1986, 15 (05): : 531 - 533
  • [14] Directional analysis of the 12-lead electrocardiogram
    Warner, RA
    Travis, A
    Lawson, WT
    Hill, NE
    Wagner, GS
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 733 - 736
  • [15] Linear affine transformations between 3-lead (Frank XYZ leads) vectorcardiogram and 12-lead electrocardiogram signals
    Dawson, Drew
    Yang, Hui
    Malshe, Milind
    Bukkapatnam, Satish T. S.
    Benjamin, Bruce
    Komanduri, Ranga
    JOURNAL OF ELECTROCARDIOLOGY, 2009, 42 (06) : 622 - 630
  • [16] SIMPLIFIED DISPLAY OF 12-LEAD ELECTROCARDIOGRAM
    GRANT, C
    BOUSVAROS, G
    CLINICAL RESEARCH, 1976, 24 (03): : A219 - A219
  • [17] Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities
    Drew, BJ
    Pelter, MM
    Wung, SF
    Adams, MG
    Taylor, C
    Evans, GT
    Foster, E
    JOURNAL OF ELECTROCARDIOLOGY, 1999, 32 : 38 - 47
  • [18] Role of lead aVR in evaluation of 12-lead electrocardiogram
    Siddiqui, MA
    Khan, IA
    ANGIOLOGY, 2002, 53 (06) : 709 - 713
  • [19] VENTRICULAR GRADIENT IN SPACE AS DETERMINED FROM THE 12-LEAD ELECTROCARDIOGRAM
    BRINBERG, L
    CIRCULATION, 1957, 16 (05) : 863 - 863
  • [20] DERIVING THE 12-LEAD ELECTROCARDIOGRAM FROM 4 (EASI) ELECTRODES
    DOWER, GE
    YAKUSH, A
    NAZZAL, SB
    JUTZY, RV
    RUIZ, CE
    JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 : S182 - S187