Volumetric particle image velocimetry with a single plenoptic camera

被引:151
作者
Fahringer, Timothy W. [1 ]
Lynch, Kyle P. [2 ]
Thurow, Brian S. [1 ]
机构
[1] Auburn Univ, Auburn, AL 36849 USA
[2] Delft Univ Technol, NL-2628 CD Delft, Netherlands
关键词
3D PIV; light field imaging; plenoptic camera; tomography; volume reconstruction; LIGHT-FIELD; FLOW; MICROSCOPE;
D O I
10.1088/0957-0233/26/11/115201
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel three-dimensional (3D), three-component (3C) particle image velocimetry (PIV) technique based on volume illumination and light field imaging with a single plenoptic camera is described. A plenoptic camera uses a densely packed microlens array mounted near a high resolution image sensor to sample the spatial and angular distribution of light collected by the camera. The multiplicative algebraic reconstruction technique (MART) computed tomography algorithm is used to reconstruct a volumetric intensity field from individual snapshots and a cross-correlation algorithm is used to estimate the velocity field from a pair of reconstructed particle volumes. This work provides an introduction to the basic concepts of light field imaging with a plenoptic camera and describes the unique implementation of MART in the context of plenoptic image data for 3D/3C PIV measurements. Simulations of a plenoptic camera using geometric optics are used to generate synthetic plenoptic particle images, which are subsequently used to estimate the quality of particle volume reconstructions at various particle number densities. 3D reconstructions using this method produce reconstructed particles that are elongated by a factor of approximately 4 along the optical axis of the camera. A simulated 3D Gaussian vortex is used to test the capability of single camera plenoptic PIV to produce a 3D/3C vector field, where it was found that lateral displacements could be measured to approximately 0.2 voxel accuracy in the lateral direction and 1 voxel in the depth direction over a 300x200x200 voxel volume. The feasibility of the technique is demonstrated experimentally using a home-built plenoptic camera based on a 16-megapixel interline CCD camera and a 289 x 193 array of microlenses and a pulsed Nd:YAG laser. 3D/3C measurements were performed in the wake of a low Reynolds number circular cylinder and compared with measurements made using a conventional 2D/2C PIV system. Overall, single camera plenoptic PIV is shown to be a viable 3D/3C velocimetry technique.
引用
收藏
页数:25
相关论文
共 39 条
[1]   SINGLE LENS STEREO WITH A PLENOPTIC CAMERA [J].
ADELSON, EH ;
WANG, JYA .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :99-106
[2]  
Adrian R J., 2011, Particle Image Velocimetry
[3]  
[Anonymous], 1991, COMPUTATIONAL MODELS
[4]  
[Anonymous], EXP FLUIDS
[5]  
[Anonymous], 2009, 2009 IEEE INT C COMP
[6]  
[Anonymous], MEAS SCI TECHNOL
[7]  
[Anonymous], APPL AER C
[8]  
[Anonymous], 2006, DIGITAL LIGHT FIELD
[9]  
[Anonymous], INFORMATIONAL
[10]  
[Anonymous], 15 INT S APPL LAS TE