Optimization and repeatability of multipool chemical exchange saturation transfer MRI of the prostate at 3.0 T

被引:18
作者
Evans, Vincent Stephen [1 ]
Torrealdea, Francisco [1 ]
Rega, Marilena [2 ]
Appayya, Mrishta Brizmohun [1 ]
Latifoltojar, Arash [1 ]
Sidhu, Harbir [1 ,3 ]
Kim, Mina [4 ]
Kujawa, Aaron [4 ]
Punwani, Shonit [1 ]
Golay, Xavier [4 ]
Atkinson, David [1 ]
机构
[1] UCL, Ctr Med Imaging, 43-45 Foley St, London W1W 7TS, England
[2] Univ Coll London Hosp NHS Fdn Trust, Univ Coll Hosp, Inst Nucl Med, London, England
[3] Univ Coll London Hosp NHS Fdn Trust, Univ Coll Hosp, Radiol Dept, London, England
[4] UCL, Inst Neurol, London, England
基金
英国工程与自然科学研究理事会;
关键词
CEST; prostate; repeatability; optimization; cancer; PROTON-TRANSFER APT; MAGNETIZATION-TRANSFER; TRANSFER CEST; HUMAN BRAIN; IN-VIVO; WATER RESONANCE; CANCER; REPRODUCIBILITY; BREAST; FEASIBILITY;
D O I
10.1002/jmri.26690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Chemical exchange saturation transfer (CEST) can potentially support cancer imaging with metabolically derived information. Multiparametric prostate MRI has improved diagnosis but may benefit from additional information to reduce the need for biopsies. Purpose To optimize an acquisition and postprocessing protocol for 3.0 T multipool CEST analysis of prostate data and evaluate the repeatability of the technique. Study Type Prospective. Subjects Five healthy volunteers (age range: 24-47 years; median age: 28 years) underwent two sessions (interval range: 7-27 days; median interval: 20 days) and two biopsy-proven prostate cancer patients were evaluated once. Patient 1 (71 years) had a Gleason 3 + 4 transition zone (TZ) tumor and patient 2 (55 years) had a Gleason 4 + 3 peripheral zone (PZ) tumor. Field Strength 3.0 T. Sequences run: T-2-weighted turbo-spin-echo (TSE); diffusion-weighted imaging; CEST; WASABI (for B-0 determination). Assessment Saturation, readout, and fit-model parameters were optimized to maximize in vivo amide and nuclear Overhauser effect (NOE) signals. Repeatability (intrasession and intersession) was evaluated in healthy volunteers. Subsequently, preliminary evaluation of signal differences was made in patients. Regions of interest were drawn by two post-FRCR board-certified readers, both with over 5 years of experience in multiparametric prostate MRI. Statistical Tests Repeatability was assessed using Bland-Altman analysis, coefficient of variation (CV), and 95% limits of agreement (LOA). Statistical significance of CEST contrast was calculated using a nonparametric Mann-Whitney U-test. Results The optimized saturation scheme was found to be 60 sinc-Gaussian pulses with 40 msec pulse duration, at 50% duty-cycle with continuous-wave pulse equivalent B1 power (B1(CWPE)) of 0.92 mu T. The magnetization transfer (MT) contribution to the fit-model was centered at -1.27 ppm. Intersession coefficients of variation (CVs) of the amide, NOE, and magnetization transfer (MT) and asymmetric magnetization transfer ratio (MTRasym) signals of 25%, 23%, 18%, and 200%, respectively, were observed. Fit-metric and MTRasym CVs agreed between readers to within 4 and 10 percentage points, respectively. Data Conclusion Signal differences of 0.03-0.10 (17-43%) detectable depending upon pool, with MT the most repeatable (signal difference of 17-22% detectable). Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1238-1250.
引用
收藏
页码:1238 / 1250
页数:13
相关论文
共 37 条
  • [1] Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study
    Ahmed, Hashim U.
    Bosaily, Ahmed El-Shater
    Brown, Louise C.
    Gabe, Rhian
    Kaplan, Richard
    Parmar, Mahesh K.
    Collaco-Moraes, Yolanda
    Ward, Katie
    Hindley, Richard G.
    Freeman, Alex
    Kirkham, Alex P.
    Oldroyd, Robert
    Parker, Chris
    Emberton, Mark
    [J]. LANCET, 2017, 389 (10071) : 815 - 822
  • [2] Quantitative Magnetization Transfer Imaging of the Breast at 3.0 T: Reproducibility in Healthy Volunteers
    Arlinghaus, Lori R.
    Dortch, Richard D.
    Whisenant, Jennifer G.
    Kang, Hakmook
    Abramson, Richard G.
    Yankeelov, Thomas E.
    [J]. TOMOGRAPHY, 2016, 2 (04) : 260 - 266
  • [3] ESUR prostate MR guidelines 2012
    Barentsz, Jelle O.
    Richenberg, Jonathan
    Clements, Richard
    Choyke, Peter
    Verma, Sadhna
    Villeirs, Geert
    Rouviere, Olivier
    Logager, Vibeke
    Futterer, Jurgen J.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (04) : 746 - 757
  • [4] Diagnostic evaluation of magnetization transfer and diffusion kurtosis imaging for prostate cancer detection in a re-biopsy population
    Barrett, Tristan
    McLean, Mary
    Priest, Andrew N.
    Lawrence, Edward M.
    Patterson, Andrew J.
    Koo, Brendan C.
    Patterson, Ilse
    Warren, Anne Y.
    Doble, Andrew
    Gnanapragasam, Vincent J.
    Kastner, Christof
    Gallagher, Ferdia A.
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (08) : 3141 - 3150
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Standardization of Multiparametric Prostate MR Imaging Using PI-RADS
    Bomers, Joyce G. R.
    Barentsz, Jelle O.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [7] CEST signal at 2ppm (CEST@2ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor
    Cai, Kejia
    Singh, Anup
    Poptani, Harish
    Li, Weiguo
    Yang, Shaolin
    Lu, Yang
    Hariharan, Hari
    Zhou, Xiaohong J.
    Reddy, Ravinder
    [J]. NMR IN BIOMEDICINE, 2015, 28 (01) : 1 - 8
  • [8] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [9] Mapping of Amide, Amine, and Aliphatic Peaks in the CEST Spectra of Murine Xenografts at 7 T
    Desmond, Kimberly L.
    Moosvi, Firas
    Stanisz, Greg J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1841 - 1853
  • [10] Amide proton transfer imaging of the breast at 3 T: Establishing reproducibility and possible feasibility assessing chemotherapy response
    Dula, Adrienne N.
    Arlinghaus, Lori R.
    Dortch, Richard D.
    Dewey, Blake E.
    Whisenant, Jennifer G.
    Ayers, Gregory D.
    Yankeelov, Thomas E.
    Smith, Seth A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 216 - 224