Assessment of capacity curves for transmission line towers under wind loading

被引:6
|
作者
Banik, S. S. [1 ]
Hong, H. P. [1 ]
Kopp, Gregory A. [1 ]
机构
[1] Univ Western Ontario, Dept Civil & Environm Engn, London, ON N6A 5B9, Canada
关键词
Transmission tower; wind load; nonlinear static pushover analysis; incremental dynamic analysis; capacity curve; TORNADO;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The recommended factored design wind load effects for overhead lattice transmission line towers by codes and standards are evaluated based on the applicable wind load factor, gust response factor and design wind speed. The current factors and design wind speed were developed considering linear elastic responses and selected notional target safety levels. However, information on the nonlinear inelastic responses of such towers under extreme dynamic wind loading, and on the structural capacity curves of the towers in relation to the design capacities, is lacking. The knowledge and assessment of the capacity curve, and its relation to the design strength, is important to evaluate the integrity and reliability of these towers, Such an assessment was performed in the present study, using a nonlinear static pushover (NSP) analysis and incremental dynamic analysis (IDA), both of which are commonly used in earthquake engineering. For the IDA, temporal and spatially varying wind speeds are simulated based on power spectral density and coherence functions. Numerical results show that the structural capacity curves of the tower determined from the NSP analysis depend on the load pattern, and that the curves determined from the nonlinear static pushover analysis are similar to those obtained from IDA.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [1] Dynamic response of transmission lines guyed towers under wind loading
    Gani, F.
    Legeron, F.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2010, 37 (03) : 450 - 464
  • [2] Capacity of a transmission tower under downburst wind loading
    Mara, T. G.
    Hong, H. P.
    Lee, C. S.
    Ho, T. C. E.
    WIND AND STRUCTURES, 2016, 22 (01) : 65 - 87
  • [3] Examination of Yawed Wind Loading on Transmission Towers
    Mara, T. G.
    Behncke, R. H.
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 522 - 537
  • [4] Dynamic behavior and stability of transmission line towers under wind forces
    Battista, RC
    Rodrigues, RS
    Pfeil, MS
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2003, 91 (08) : 1051 - 1067
  • [5] Design of shallow foundations under tensile loading for transmission line towers: An overview
    Pacheco, M. P.
    Danziger, F. A. B.
    Pinto, C. Pereira
    ENGINEERING GEOLOGY, 2008, 101 (3-4) : 226 - 235
  • [6] Behavior of self supported transmission line towers under stationary downburst loading
    Darwish, Mohamed M.
    El Damatty, Ashraf A.
    WIND AND STRUCTURES, 2011, 14 (05) : 481 - 498
  • [7] Comparison of Responses of Guyed and Freestanding Transmission Line Towers Under Conductor Breakage Loading
    Alminhana, Fabio
    Albermani, Faris
    Mason, Matthew
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2015, 15 (08)
  • [8] Collapse mechanisms of power towers under wind loading
    Tapia-Hernandez, Edgar
    Ibarra-Gonzalez, Santiago
    De-Leon-Escobedo, David
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2017, 13 (06) : 766 - 782
  • [9] Optimum design of transmission towers subjected to wind and earthquake loading
    Galeb, A. C. (alaagaleb@yahoo.com), 1600, Jordan University of Science and Technology (07):
  • [10] Collapse mechanisms of power towers under wind loading
    Tapia-Hernández, Edgar
    Ibarra-González, Santiago
    De-León-Escobedo, David
    Structure and Infrastructure Engineering, 2017, 13 (06): : 766 - 782