A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis

被引:236
作者
Zhang, Yiheng [1 ]
Chan, Heang-Ping [1 ]
Sahiner, Berkman [1 ]
Wei, Jun [1 ]
Goodsitt, Mitchell M. [1 ]
Hadjiiski, Lubomir M. [1 ]
Ge, Jun [1 ]
Zhou, Chuan [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
digital tomosynthesis mammography (DTM); limited-angle cone-beam tomography; simultaneous algebraic reconstruction technique (SART); maximum likelihood method with convex algorithm (ML-convex);
D O I
10.1118/1.2237543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital tomosynthesis mammography (DTM) is a promising new modality for breast cancer detection. In DTM, projection-view images are acquired at a limited number of angles over a limited angular range and the imaged volume is reconstructed from the two-dimensional projections, thus providing three-dimensional structural information of the breast tissue. In this work, we investigated three representative reconstruction methods for this limited-angle cone-beam tomographic problem, including the backprojection (BP) method, the simultaneous algebraic reconstruction technique (SART) and the maximum likelihood method with the convex algorithm (ML-convex). The SART and ML-convex methods were both initialized with BP results to achieve efficient reconstruction. A second generation GE prototype tomosynthesis mammography system with a stationary digital detector was used for image acquisition. Projection-view images were acquired from 21 angles in 3 increments over a 30 angular range. We used an American College of Radiology phantom and designed three additional phantoms to evaluate the image quality and reconstruction artifacts. In addition to visual comparison of the reconstructed images of different phantom sets, we employed the contrast-to-noise ratio (CNR), a line profile of features, an artifact spread function (ASF), a relative noise power spectrum (NPS), and a line object spread function (LOSF) to quantitatively evaluate the reconstruction results. It was found that for the phantoms with homogeneous background, the BP method resulted in less noisy tomosynthesized images and higher CNR values for masses than the SART and ML-convex methods. However, the two iterative methods provided greater contrast enhancement for both masses and calcification, sharper LOSF, and reduced inter-plane blurring and artifacts with better ASF behaviors for masses. For a contrast-detail phantom with heterogeneous tissue-mimicking background, the BP method had strong blurring artifacts along the x-ray source motion direction that obscured the contrast-detail objects, while the other two methods can remove the superimposed breast structures and significantly improve object conspicuity. With a properly selected relaxation parameter, the SART method with one iteration can provide tomosynthesized images comparable to those obtained from the ML-convex method with seven iterations, when BP results were used as initialization for both methods. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3781 / 3795
页数:15
相关论文
共 49 条
  • [1] Performance of advanced a-Si/CsI-based flat panel x-ray detectors for mammography
    Albagli, D
    Hudspeth, H
    Possin, G
    Lee, J
    Granfors, P
    Giambattista, B
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 553 - 563
  • [2] SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM
    ANDERSEN, AH
    KAK, AC
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 81 - 94
  • [3] ALGEBRAIC RECONSTRUCTION IN CT FROM LIMITED VIEWS
    ANDERSEN, AH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (01) : 50 - 55
  • [4] Measurement of the noise power spectrum in digital x-ray detectors
    Aufrichtig, R
    Su, Y
    Cheng, Y
    Granfors, PR
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 362 - 372
  • [5] Initial application of digital tomosynthesis with on-board imaging in radiation oncology
    Baydush, AH
    Godfrey, DJ
    Oldham, M
    Dobbins, JT
    [J]. Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1300 - 1305
  • [6] Digital breast tomosynthesis using an amorphous selenium flat panel detector
    Bissonnette, M
    Hansroul, M
    Masson, E
    Savard, S
    Cadieux, S
    Warmoes, P
    Gravel, D
    Agopyan, J
    Polischuk, B
    Haerer, W
    Mertelmeier, T
    Lo, JY
    Chen, Y
    Dobbins, JT
    Jesneck, JL
    Singh, S
    [J]. Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 529 - 540
  • [7] An adapted fan volume sampling scheme for 3-D algebraic reconstruction in linear tomosynthesis
    Bleuet, P
    Guillemaud, R
    Desbat, L
    Magnin, I
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2366 - 2372
  • [8] Accelerating the EMML algorithm and related iterative algorithms by rescaled block-iterative methods
    Byrne, CL
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 1998, 7 (01) : 100 - 109
  • [9] Cone-beam volume CT breast imaging: Feasibility study
    Chen, B
    Ning, R
    [J]. MEDICAL PHYSICS, 2002, 29 (05) : 755 - 770
  • [10] A new method for 3D reconstruction in digital tomosynthesis
    Claus, BEH
    Eberhard, JW
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 814 - 824