Leak detection and location in liquid pipelines by analyzing the first transient pressure wave with unsteady friction

被引:22
作者
Diao, Xu [1 ,2 ]
Shen, Guodong [1 ,2 ]
Jiang, Juncheng [1 ,2 ]
Chen, Qiang [1 ,2 ]
Wang, Zhirong [1 ,2 ]
Ni, Lei [1 ,2 ]
Mebarki, Ahmed [1 ,2 ,3 ,5 ]
Dou, Zhan [4 ]
机构
[1] Nanjing Tech Univ, Coll Safety Sci & Engn, Nanjing 210009, Jiangsu, Peoples R China
[2] Jiangsu Key Lab Hazardous Chem Safety & Control, Nanjing 211800, Jiangsu, Peoples R China
[3] Univ Paris Est, Lab Multi Scale Modeling & Simulat, MSME, CNRS,UMR 8208, 5 Bd Descartes, F-77454 Marne La Vallee 2, France
[4] Tsinghua Univ, Inst Measurement & Elect Technol, Dept Automat, Beijing 100084, Peoples R China
[5] Nanjing Tech Univ, High Level Foreign Talents Programe Grant, Nanjing, Jiangsu, Peoples R China
基金
国家重点研发计划;
关键词
Leak detection; Pipelines; Transient pressure; Unsteady friction; Two leaks; PIPE SYSTEMS; WATER; MODEL;
D O I
10.1016/j.jlp.2019.04.017
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Leakages in pipelines can cause serious consequences, such as economic loss, or fire and explosion. Hence, leak detection and location techniques are of crucial importance for pipeline maintenance, safety of industry facilities and environment. A modified transient-based method is proposed in this paper for leak detection and location in a reservoir-pipe-valve (RPV) system. The leak location model is based on the time when a pressure wave propagates from the valve to the leak location and back again. Furthermore, in the leak detection model, the onedimensional unsteady friction model is introduced into Method of Characteristics (MOC). Then, the governing equations are derived as a ternary system of equations, in which the unknown parameters, especially leak size coefficient, are obtained by analyzing the first transient pressure wave. To validate the method efficiency, both one leak and two leaks situations are taken into consideration in simulation. The simulated results show notable correlations between the model and real leak locations. Additionally, the errors between calculated and actual values of the parameters remain in acceptable ranges. Finally, the developed method is verified by experimental data, and the results demonstrate that it has high accuracy and shows a great performance in leak detection and location.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 30 条
[1]   Developments in unsteady pipe flow friction modelling [J].
Bergant, A ;
Simpson, AR ;
Vítkovsky, J .
JOURNAL OF HYDRAULIC RESEARCH, 2001, 39 (03) :249-257
[2]  
Brunone B., 1991, P INT M HYDR TRANS C, P140
[3]   A selective literature review of transient-based leak detection methods [J].
Colombo, Andrew F. ;
Lee, Pedro ;
Karney, Bryan W. .
JOURNAL OF HYDRO-ENVIRONMENT RESEARCH, 2009, 2 (04) :212-227
[4]   Standing wave difference method for leak detection in pipeline systems [J].
Covas, D ;
Ramos, H ;
de Almeida, AB .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2005, 131 (12) :1106-1116
[5]   The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part I - experimental analysis and creep characterization [J].
Covas, D ;
Stoianov, I ;
Mano, JF ;
Ramos, H ;
Graham, N ;
Maksimovic, C .
JOURNAL OF HYDRAULIC RESEARCH, 2004, 42 (05) :516-530
[6]   Case Studies of Leak Detection and Location in Water Pipe Systems by Inverse Transient Analysis [J].
Covas, Didia ;
Ramos, Helena .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2010, 136 (02) :248-257
[7]   Uncertainty Analysis of Transient Flow Modeling and Transient-Based Leak Detection in Elastic Water Pipeline Systems [J].
Duan, Huan-Feng .
WATER RESOURCES MANAGEMENT, 2015, 29 (14) :5413-5427
[8]   Analysis of the smallest detectable leakage flow rate of negative pressure wave-based leak detection systems for liquid pipelines [J].
Ge Chuanhu ;
Wang Guizeng ;
Ye Hao .
COMPUTERS & CHEMICAL ENGINEERING, 2008, 32 (08) :1669-1680
[9]   Frequency Response Diagram for Pipeline Leak Detection: Comparing the Odd and Even Harmonics [J].
Gong, Jinzhe ;
Zecchin, Aaron C. ;
Simpson, Angus R. ;
Lambert, Martin F. .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2014, 140 (01) :65-74
[10]   Single-Event Leak Detection in Pipeline Using First Three Resonant Responses [J].
Gong, Jinzhe ;
Lambert, Martin F. ;
Simpson, Angus R. ;
Zecchin, Aaron C. .
JOURNAL OF HYDRAULIC ENGINEERING, 2013, 139 (06) :645-655