Simultaneous quantification of fexofenadine and pseudoephedrine in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: method development, validation and application to a clinical study

被引:20
|
作者
Nirogi, Ramakrishna V. S. [1 ]
Kandikere, Vishwottam N. [1 ]
Shukla, Manoj [1 ]
Mudigonda, Koteshwara [1 ]
Maurya, Santosh [1 ]
Komarneni, Prashanth [1 ]
机构
[1] Suven Life Sci Ltd, Hyderabad 500034, Andhra Pradesh, India
关键词
D O I
10.1002/rcm.2701
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To support the pharmacokinetic and bioavailability study of a once-daily fexofenadine/pseudoephedrine combination, a high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for the simultaneous quantification of fexofenadine and pseudoephedrine was developed and validated with 500 mu L human plasma using mosapride as an internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 502/466 for fexofenadine, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited linear dynamic ranges of 1-500 ng/ mL and 2-1000 ng/mL for fexofenadine and pseudoephedrine, respectively, in human plasma. The lower limits of quantification were 1 and 2 ng/mL with a relative standard deviation of less than 10% for fexofenadine and pseudoephedrine, respectively. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time was 2 min and more than 400 human plasma samples could be analyzed in one day by running the system overnight. The method is precise and sensitive enough for its intended purpose. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:3030 / 3038
页数:9
相关论文
共 50 条
  • [1] Quantification of roxatidine in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry: Application to a bioequivalence study
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Heon-Woo
    Choi, Seung-Ki
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 143 - 147
  • [2] Reverse-phase liquid chromatography with electrospray ionization/mass spectrometry for the quantification of pseudoephedrine in human plasma and application to a bioequivalence study
    Kim, Jin-Ki
    Jee, Jun-Pil
    Park, Jeong-Sook
    Kim, Hyung Tae
    Kim, Chong-Kook
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (05): : 276 - 281
  • [3] Development and validation of a liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of tamoxifen, anastrozole, and letrozole in human plasma and its application to a clinical study
    Beate Beer
    Birthe Schubert
    Anne Oberguggenberger
    Verena Meraner
    Michael Hubalek
    Herbert Oberacher
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1791 - 1800
  • [4] Liquid chromatography/electrospray ionization tandem mass spectrometry for the quantification of mitiglinide in human plasma: validation and its application to pharmacokinetic studies
    Zhang, Yan
    Ding, Likun
    Tian, Yun
    Yang, Jing
    Yang, Lin
    Wen, Aidong
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (08) : 873 - 878
  • [5] Development and Validation of a Liquid Chromatography-tandem Mass Spectrometry Method for the Simultaneous Determination of Acrivastine and Pseudoephedrine in Human Plasma and its Application in Pharmacokinetics
    He, J. -C.
    Feng, E. -F.
    Liu, M.
    Li, H. -L.
    Tian, M.
    Zhang, Q.
    Dong, L. -C.
    Xu, G. -L.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (10): : 449 - 456
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of tamoxifen, anastrozole, and letrozole in human plasma and its application to a clinical study
    Beer, Beate
    Schubert, Birthe
    Oberguggenberger, Anne
    Meraner, Verena
    Hubalek, Michael
    Oberacher, Herbert
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (04) : 1791 - 1800
  • [7] Determination and Quantification of Phenytoin in Human Plasma by Liquid Chromatography with Electrospray Ionization Tandem Mass Spectrometry
    Roy, S. M. N.
    Yetal, S. M.
    Vaidya, V. V.
    Joshi, S. S.
    E-JOURNAL OF CHEMISTRY, 2008, 5 (01) : 169 - 176
  • [8] Quantification of Paroxetine in Human Plasma by Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry
    Shah, Hiten J.
    Kundlik, Mohan L.
    Kakad, Abhijit
    Patel, Nitesh K.
    Pandya, Ankit
    Khatri, Vanita
    Prajapati, Shivkumat
    Subbaiah, Gunta
    Patel, Chhagan N.
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (01) : 141 - 149
  • [9] Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Bhatt, Jignesh
    Jangid, Arvind
    Shetty, Raghavendra
    Shah, Bhavin
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 736 - 742
  • [10] Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study
    Zhang, Lu
    Tian, Yuan
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2): : 91 - 98