CONSIDERING ON LIGHTNING ELECTRIC FIELDS IN PRESENCE OF GROUND REFLECTION AT NON-PERFECT GROUND

被引:0
|
作者
Izadi, Mandi [1 ]
Ab Kadir, M. Z. A. [2 ]
Hajikhani, Maryam [3 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Ctr Elect & Lightning Protect Res, Serdang 43400, Selangor, Malaysia
[2] Islamic Azad Univ, Dept Elect, Firoozkooh Branch, Firoozkooh, Iran
[3] Aryaphase Co, Tehran, Iran
关键词
lightning; electromagnetic fields; ground conductivity; ground reflection factor; ELECTROMAGNETIC-FIELDS; RETURN-STROKE; MAGNETIC-FIELDS; TIME-DOMAIN; CHANNEL; IDENTIFICATION; INTERMEDIATE; EXPRESSIONS; ALGORITHM; LINES;
D O I
10.2478/jee-2014-0037
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, general electric field expressions are proposed to consider the effect of channel base ground reflections and ground conductivity on the electric field components due to lightning. The proposed method can support different current models and functions directly in the time domain without the need to apply any extra conversions. The proposed method is applied on a sample of measured channel base current from triggered lightning experiment and the results are discussed accordingly. The results show that the ground reflection and ground conductivity can have an effect on the peak values of the electric fields whereby the electric field components have a great effect on the widely used coupling models.
引用
收藏
页码:242 / 247
页数:6
相关论文
共 50 条
  • [21] Electric Field Close to Lightning Channel in the Presence of Current Reflections from the Ground
    Cvetic, Jovan
    Ignjatovic, Milan
    Tausanovic, Milica
    Mijajlovic, Nikola
    Pavlovic, Dragan
    Heidler, Fridolin
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [22] The analytical field expressions associated with lightning channel in presence of ground reflection at striking point
    Izadi, M.
    Ab Kadir, M. Z. A.
    Hajikhani, M.
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2013, 42 (02) : 303 - 317
  • [23] Measurement results of the electric fields in cloud-to-ground lightning in nearby Munich, Germany
    Heidler, F
    Hopf, C
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1998, 40 (04) : 436 - 443
  • [24] 3D computation of lightning electromagnetic fields in the presence of a horizontally stratified ground
    Arzag K.
    Azzouz Z.-E.
    Baba Y.
    Ghemri B.
    International Journal of Power and Energy Systems, 2018, 37 (04): : 120 - 128
  • [25] Measurement results of the electric fields in cloud-to-ground lightning in nearby Munich, Germany
    Univ of Federal Armed Forces, Neubiberg, Germany
    IEEE Trans Electromagn Compat, 4 pt 2 (436-443):
  • [26] Distribution of cloud-to-ground lightning electromagnetic pulse fields under the ground
    Yang Bo
    Zhou Bi-Hua
    Meng Xin
    ACTA PHYSICA SINICA, 2010, 59 (12) : 8978 - 8985
  • [27] On symplectic polar spaces over non-perfect fields of characteristic 2
    De Bruyn, B.
    Pasini, A.
    LINEAR & MULTILINEAR ALGEBRA, 2009, 57 (06): : 567 - 575
  • [28] Evaluation of lightning electromagnetic fields over a lossy ground
    Delfino, F
    Procopio, R
    Rossi, M
    Boundary Elements XXVII: Incorporating Electrical Engineering and Electromagnetics, 2005, 39 : 619 - 629
  • [29] The Effect of a Horizontally Stratified Ground on Lightning Electromagnetic Fields
    Delfino, F.
    Procopio, R.
    Rossi, M.
    Shoory, A.
    Rachidi, F.
    2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC 2010), 2010, : 45 - 50
  • [30] Distant Electric Field Caused by Cloud to Ground Lightning
    Maslowski, Grzegorz
    Bajorek, Jerzy
    Baranski, Piotr