Effect of buffer on peak shape of peptides in reversed-phase high performance liquid chromatography

被引:78
作者
McCalley, DV [1 ]
机构
[1] Univ W England, Fac Sci Appl, Ctr Biomed Res, Bristol BS16 1QY, Avon, England
关键词
peak shape; mobile phase composition; buffer composition; peptides;
D O I
10.1016/j.chroma.2004.03.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of changing the buffer at constant low pH in the mobile phase is investigated with respect to the separation of a mixture of basic peptides. Considerably worse peak shapes, leading to poorer resolution of complex peptide mixtures, were obtained when using formic acid favoured in LC-MS applications compared with non volatile phosphate buffers or with trifluoroacetic acid (TFA). Poorer peak shapes were largely attributable to reduced column capacity for the peptides when using mobile phases of low ionic strength, due to the increased mutual repulsion of ions held on the hydrophobic column surface which is facilitated in these buffers. However, ion-pairing between the peptides and additives such as TFA or even phosphate may also lessen mutual repulsion effects, leading to greater column capacity. Overloading effects could be observed when sample masses around only 0.1 mug were injected on to standard size analytical columns in formic acid containing mobile phases; sample masses around only 1.5 mug may cause loss of half the system peak capacity in such mobile phases. Results were broadly comparable (after scaling sample size according to column diameter) on columns of both conventional (4.6 mm i.d.) and capillary (0.075 min i.d.) dimensions. Ammonium formate may be a useful alternative buffer for some applications due to its higher ionic strength. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 23 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   Overloading study of bases using polymeric RP-HPLC columns as an aid to rationalization of overloading on silica-ODS phases [J].
Buckenmaier, SMC ;
McCalley, DV ;
Euerby, MR .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4672-4681
[3]   Resolution and identification of the protein components of the photosystem II antenna system of higher plants by reversed-phase liquid chromatography with electrospray-mass spectrometric detection [J].
Corradini, D ;
Huber, CG ;
Timperio, AM ;
Zolla, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 886 (1-2) :111-121
[4]   PREPARATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY UNDER ISOCRATIC CONDITIONS .3. THE CONSEQUENCES OF 2 ADJACENT BANDS HAVING UNEQUAL COLUMN CAPACITIES [J].
COX, GB ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1989, 483 :95-110
[5]   SIMPLIFIED DESCRIPTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION UNDER OVERLOAD CONDITIONS, BASED ON THE CRAIG DISTRIBUTION MODEL .2. EFFECT OF ISOTHERM TYPE, AND EXPERIMENTAL-VERIFICATION OF COMPUTER-SIMULATIONS FOR A SINGLE BAND [J].
EBLE, JE ;
GROB, RL ;
ANTLE, PE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :45-79
[6]  
Ettre LS, 2003, LC GC EUR, V16, P192
[7]   Effect of the ionic strength of salts on retention and overloading behavior of ionizable compounds in reversed-phase liquid chromatography II.: Symmetry-C18 [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (01) :57-69
[8]   Evaluation of volatile eluents and electrolytes for high-performance liquid chromatography-electrospray ionization mass spectrometry and capillary electrophoresis-electrospray ionization mass spectrometry of proteins - I. Liquid chromatography [J].
Huber, CG ;
Premstaller, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (01) :161-173
[9]   Effect of experimental parameters on the HPLC separation of peptides and proteins [J].
Issaq, HJ ;
Fox, SD ;
Mahadevan, M ;
Conrads, TP ;
Veenstra, TD .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (14) :2255-2283
[10]   Factors to consider in the development of generic bioanalytical high-performance liquid chromatographic-mass spectrometric methods to support drug discovery [J].
Law, B ;
Temesi, D .
JOURNAL OF CHROMATOGRAPHY B, 2000, 748 (01) :21-30