Comparative study of FDG PET/CT and conventional imaging in the staging of rhabdomyosarcoma

被引:82
作者
Tateishi, Ukihide [1 ]
Hosono, Ako [2 ]
Makimoto, Atsushi [2 ]
Nakamoto, Yuki [3 ]
Kaneta, Tomohiro [4 ]
Fukuda, Hiroshi [4 ]
Murakami, Koji [5 ]
Terauchi, Takashi [6 ]
Suga, Tsuyoshi [3 ]
Inoue, Tomio [1 ]
Kim, Edmund E. [7 ]
机构
[1] Yokohama City Univ, Dept Radiol, Sch Med, Kanazawa Ku, Kanagawa 2360004, Japan
[2] Natl Canc Ctr, Div Pediat Oncol, Tokyo, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, Kyoto, Japan
[4] Kyoto Univ, Dept Diagnost Radiol, Grad Sch Med, Sendai, Miyagi, Japan
[5] Dokkyo Med Univ, PET Ctr, Tochigi, Japan
[6] Natl Canc Ctr, Div Canc Screening, Res Ctr Canc Prevent & Screening, Tokyo 104, Japan
[7] Univ Texas MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX 77030 USA
关键词
FDG PET/CT; Rhabdomyosarcoma; Stage; POSITRON-EMISSION-TOMOGRAPHY; SOFT-TISSUE SARCOMA; NEOPLASMS; CHILDREN; TUMORS; BONE;
D O I
10.1007/s12149-008-0219-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current study was conducted to compare the diagnostic accuracy between (18)F-fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET)/computed tomography (CT), and conventional imaging (CI) for the staging and re-staging of patients with rhabdomyosarcomas. Thirty-five patients who underwent FDG PET/CT prior to treatment were evaluated retrospectively. CI methods consisted of (99m)Tc-hydroxymethylene diphosphonate bone scintigraphy, chest radiograph, whole body CT, and magnetic resonance imaging of the primary site. The images were reviewed and two boardcertified radiologists reached a diagnostic consensus. Tumor stage was confirmed by histological examination and/or follow-up examinations. Interpretation on the basis of FDG PET/CT, and CI, diagnostic accuracies of the T and N stages were similar. Using FDG PET/CT, the M stage was correctly assigned in 31 patients (89%), whereas the accuracy of CI in M stage was 63%. TNM stage was correctly assessed with FDG PET/CT in 30 of 35 patients (86%) and with CI in 19 of 35 patients (54%). The overall TNM staging and M staging accuracies of FDG PET/CT were significantly higher than that of CI (P < 0.01). FDG PET/CT is more accurate than CI regarding clinical staging and re-staging of patients with rhabdomyosarcomas.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 15 条
[1]  
Bar-Shalom R, 2003, J NUCL MED, V44, P1200
[2]   The risk of developing second cancers among survivors of childhood soft tissue sarcoma [J].
Cohen, RJ ;
Curtis, RE ;
Inskip, PD ;
Fraumeni, JF .
CANCER, 2005, 103 (11) :2391-2396
[3]  
Eary JF, 1998, CLIN CANCER RES, V4, P1215
[4]   FDG-PET for detection of osseous metastases from malignant primary bone tumours:: comparison with bone scintigraphy [J].
Franzius, C ;
Sciuk, J ;
Daldrup-Link, HE ;
Jürgens, H ;
Schober, O .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (09) :1305-1311
[5]  
HATESJORDAN A, 2006, J PEDIATR, V41, P633
[6]   PET for staging in rhabdomyosarcoma:: An evaluation of PET as an adjunct to current staging tools [J].
Klem, Michelle L. ;
Grewal, Ravinder K. ;
Wexler, Leonard H. ;
Schoder, Heiko ;
Meyers, Paul A. ;
Wolden, Suzanne L. .
JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2007, 29 (01) :9-14
[7]   PET/CT in the evaluation of childhood sarcomas [J].
McCarville, MB ;
Christie, R ;
Daw, NC ;
Spunt, SL ;
Kaste, SC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) :1293-1304
[8]  
Nieweg OE, 1996, J NUCL MED, V37, P257
[9]   Use of 2-deoxy-2-[F-18]-fluoro-D-glucose positron emission tomography to monitor therapeutic response by rhabdomyosarcoma in children: Report of a retrospective case study [J].
Peng, Fangyu ;
Rabkin, Galina ;
Muzik, Otto .
CLINICAL NUCLEAR MEDICINE, 2006, 31 (07) :394-397
[10]   Second malignant neoplasms in children after treatment of soft tissue sarcoma [J].
Rich, DC ;
Corpron, CA ;
Smith, MB ;
Black, CT ;
Lally, KP ;
Andrassy, RJ .
JOURNAL OF PEDIATRIC SURGERY, 1997, 32 (02) :369-372