Monitoring of the core body temperature of cows using implantable wireless thermometers

被引:19
作者
Iwasaki, Wataru [1 ]
Ishida, Shuichi [1 ]
Kondo, Daisuke [2 ,4 ]
Ito, Yuichi [3 ]
Tateno, Jun [3 ]
Tomioka, Michiko [2 ,5 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Adv Mfg Res Inst, 807-1 Shuku Machi, Tosu, Saga 8410052, Japan
[2] Kitasato Univ, Sch Vet Med, Higashi 23-35-1, Towada, Aomori 0348628, Japan
[3] Murata Mfg Co Ltd, 10-1,Higashikotari 1 Chome, Nagaokakyo, Kyoto 6178555, Japan
[4] NOSAI Miyagi, Sendai, Miyagi 9800011, Japan
[5] Rakuno Gakuen Univ, Sch Vet Med, Ebetsu, Hokkaido 0698501, Japan
关键词
Cattle; Health monitoring; Body temperature; Implantable wireless thermometer; Machine learning; DAIRY-CATTLE; TIME; OVULATION; SENSOR; INSEMINATION; ESTRUS; STEERS; BASE;
D O I
10.1016/j.compag.2019.06.004
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Monitoring of cattle body temperature is useful for the detection of estrus, prediction of parturition, and maintenance of health. Recently, methods of monitoring body temperature in sites including the rumen, vagina, skin surface, and subcutis, have been studied. However, these methods are associated with limitations, such as loss of a device and the induction of stress. In addition, these studies did not consider differences among the measurement sites. In the present study, we developed implantable wireless thermometers and implanted them into a cow in 10 different anatomical locations. We then investigated the relationships among the temperatures recorded at these locations and rectal temperature (RT). The temperatures in three endoceliac and seven subcutaneous locations were monitored and compared over 6 weeks during winter. The temperatures in the abdominal cavity and inner flank wall correlated strongly with RT (r = 0.74 and 0.76, respectively). Of the subcutaneous locations, the tail-base (TB) was associated with a high reception rate for wireless transmission (97.6%) and the temperatures at this location also correlated well with RT (r = 0.62). These results indicate that the implantable wireless thermometer can continuously monitor core body temperature over a long period. Endoceliac sites and the TB are good candidates for bovine temperature monitoring. In addition, we were able to predict body temperatures that strongly correlated with the temperatures at endoceliac sites using machine learning and inputs of subcutaneous and ambient temperatures. The correlation coefficients were 0.93 when seven subcutaneous temperatures were used, and 0.77 when two were used. These results suggest that long-term monitoring of core body temperature would be possible using a wireless thermometer implanted in a subcutaneous location.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Effect of heat stress on body temperature in healthy early postpartum dairy cows
    Burfeind, O.
    Suthar, V. S.
    Heuwieser, W.
    THERIOGENOLOGY, 2012, 78 (09) : 2031 - 2038
  • [32] Implications of Changes in Core Body Temperature
    Schutz, Michael M.
    Bewley, Jeffrey M.
    PROCEEDINGS OF THE 18TH ANNUAL TRI-STATE DAIRY NUTRITION CONFERENCE, 2009, : 39 - +
  • [33] Wireless Wearable and Implantable Monitoring and Therapeutic Systems for Cardiac and Neurological Disorders
    Ramasamy, Mouli
    Varadan, Vijay
    WEARABLE SENSORS AND SYSTEMS 1 -AND - MICROFABRICATED AND NANOFABRICATED SYSTEMS FOR MEMS/NEMS 14, 2018, 86 (16): : 21 - 30
  • [34] Role of core body temperature in nephrolithiasis
    Srirangapatanam, Sudarshan
    Wiener, Scott
    Stoller, Marshall L.
    BJU INTERNATIONAL, 2020, 126 (05) : 620 - 624
  • [35] Implantable Wireless Intracranial Pressure Monitoring Based on Air Pressure Sensing
    Jiang, Hanjun
    Guo, Yanshu
    Wu, Zeliang
    Zhang, Chun
    Jia, Wen
    Wang, Zhihua
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (05) : 1076 - 1087
  • [37] Effects of changing milking and feeding times on the behaviour, body temperature, respiration rate and milk production of dairy cows on pasture
    Schutz, K. E.
    Cox, N. R.
    Cave, V. M.
    Huddart, F. J.
    Tucker, C. B.
    APPLIED ANIMAL BEHAVIOUR SCIENCE, 2023, 261
  • [38] Prediction of core body temperature using infra-red thermography in buffaloes
    Balhara, Ashok Kumar
    Jan, Mustafa Hasan
    Hooda, Ekta
    Kumar, Krishan
    Ghanghas, Amandeep
    Sangwan, Suman
    Balhara, Sunesh
    Phulia, S. K.
    Yadav, Sarita
    Boora, Ashok
    Kumar, Sanjay
    Singh, Sajjan
    Datta, T. K.
    ITALIAN JOURNAL OF ANIMAL SCIENCE, 2024, 23 (01) : 834 - 841
  • [39] Effects of adjustable and stationary fans with misters on core body temperature and lying behavior of lactating dairy cows in a semiarid climate
    Anderson, S. D.
    Bradford, B. J.
    Harner, J. P.
    Tucker, C. B.
    Choi, C. Y.
    Allen, J. D.
    Hall, L. W.
    Rungruang, S.
    Collier, R. J.
    Smith, J. F.
    JOURNAL OF DAIRY SCIENCE, 2013, 96 (07) : 4738 - 4750
  • [40] Short communication: Effect of cross ventilation with or without evaporative pads on core body temperature and resting time of lactating cows
    Smith, J. F.
    Bradford, B. J.
    Harner, J. P.
    Potts, J. C.
    Allen, J. D.
    Overton, M. W.
    Ortiz, X. A.
    Collier, R. J.
    JOURNAL OF DAIRY SCIENCE, 2016, 99 (02) : 1495 - 1500