Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement

被引:29
作者
Hoshide, Satoshi [1 ]
Yoshihisa, Akiomi [2 ,3 ]
Tsuchida, Fumihiro [4 ]
Mizuno, Hiroyuki [1 ]
Teragawa, Hiroki [5 ]
Kasai, Takatoshi [6 ]
Koito, Hitoshi [7 ]
Ando, Shin-ichi [8 ]
Watanabe, Yoshihiko [9 ]
Takeishi, Yasuchika [2 ]
Kario, Kazuomi [1 ]
机构
[1] Jichi Med Univ, Div Cardiovasc Med, Sch Med, Shimotsuke, Tochigi, Japan
[2] Fukushima Med Univ, Dept Cardiovasc Med, Fukushima, Japan
[3] Fukushima Med Univ, Dept Clin Lab Sci, Sch Hlth Sicence, Fukushima, Japan
[4] Yabuki Hosp, Dept Pulm Med, Yamagata, Japan
[5] JR Hiroshima Hosp, Dept Cardiovasc Med, Hiroshima, Japan
[6] Juntendo Univ, Dept Cardiovasc Med, Cardiovasc Resp Sleep Med, Grad Sch Med, Tokyo, Japan
[7] Misugikai Otokoyama Hosp, Dept Internal Med, Kyoto, Japan
[8] Kyushu Univ Hosp, Sleep Apnea Ctr, Fukuoka, Japan
[9] Nippon Dent Univ Hosp, Dept Internal Med, Tokyo, Japan
关键词
Pulse transit time; Beat-to-beat; Blood pressure variability; Continuous blood pressure monitoring; SLEEP; VARIABILITY; APNEA; HYPERTENSION; ANESTHESIA; MANAGEMENT; SEVERITY;
D O I
10.1038/s41440-022-00899-z
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Pulse transit time (PTT), which refers to the travel time between two arterial sites within the same cardiac cycle, has been developed as a novel cuffless form of continuous blood pressure (BP) monitoring. The aim of this study was to investigate differences in BP parameters, including BP variability, between those assessed by beat-to-beat PTT-estimated BP (eBP(BTB)) and those assessed by intermittent PTT-estimated BP at fixed time intervals (eBP(INT)) in patients suspected of having sleep disordered breathing (SDB). In 330 patients with SDB (average age, 66.8 +/- 11.9 years; 3% oxygen desaturation index [ODI], 21.0 +/- 15.0/h) from 8 institutes, PTT-estimated BP was continuously recorded during the nighttime. The average systolic eBP(BTB), maximum systolic and diastolic eBP(BTB), standard deviation (SD) of systolic and diastolic eBP(BTB), and coefficient variation (CV) of systolic and diastolic eBP(BTB) were higher than the respective values of eBP(INT) (all P < 0.05). Bland-Altman analysis showed a close agreement between eBP(BTB) and eBP(INT) in average systolic BP and SD and CV of systolic BP, while there were disagreements in both minimum and maximum values of eBP(BTB) and eBP(INT) in patients with high systolic BP (P < 0.05). Although systolic BP variability incrementally increased according to the tertiles of 3%ODI in both eBP(BTB) and eBP(INT) (all P < 0.05), there was no difference in this tendency between eBP(BTB) and eBP(INT). In patients with suspected SDB, the difference between e eBP(BTB) and eBP(INT) was minimal, and there were disagreements regarding both the minimum and maximum BP. However, there were agreements in regard to the index of BP variability between eBP(BTB) and eBP(INT).
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [41] Anxiety and hostility are associated with reduced baroreflex sensitivity and increased beat-to-beat blood pressure variability
    Virtanen, R
    Jula, A
    Salminen, JK
    Voipio-Pulkki, LM
    Helenius, H
    Kuusela, T
    Airaksinen, J
    PSYCHOSOMATIC MEDICINE, 2003, 65 (05): : 751 - 756
  • [42] Nighttime phenotype in patients with heart failure: beat-to-beat blood pressure variability predicts prognosis
    Sekizuka, Hiromitsu
    HYPERTENSION RESEARCH, 2025, : 1434 - 1436
  • [43] Short-term beat-to-beat but not ambulatory blood pressure variability is correlated to carotid intima-media thickness
    Manios, Efstathios
    Michas, Fotios
    Stamatelopoulos, Kimon
    Barlas, Gerasimos
    Koroboki, Eleni
    Tsouma, Iliana
    Vemmos, Konstantinos
    Zakopoulos, Nikolaos
    BLOOD PRESSURE MONITORING, 2014, 19 (05) : 288 - 293
  • [44] Accuracy of the CNAP monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in the prone position
    Dewhirst, Elisabeth
    Corridore, Marco
    Klamar, Jan
    Beebe, Allan
    Rice, Julie
    Barry, N'Diris
    Tobias, Joseph D.
    JOURNAL OF CLINICAL ANESTHESIA, 2013, 25 (04) : 309 - 313
  • [45] Beat-to-beat resting blood pressure variability in patients with type 2 diabetes: effect of statin therapy
    Biju, Theresa
    Young, Benjamin
    Skow, Rachel
    Nandadeva, Damsara
    Fadel, Paul
    PHYSIOLOGY, 2023, 38
  • [46] Effect of nebivolol on beat-to-beat and short-term blood pressure variability in spontaneously hypertensive rats
    Martin Bertera, Facundo
    Sofia Del Mauro, Julieta
    Hector Polizio, Ariel
    Chiappetta, Diego
    Alberto Taira, Carlos
    Hoecht, Christian
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2012, 385 (08) : 833 - 843
  • [47] Prognostic Significance of Blood Pressure Variability on Beat-to-Beat Monitoring After Transient Ischemic Attack and Stroke
    Webb, Alastair J. S.
    Mazzucco, Sara
    Li, Linxin
    Rothwell, Peter M.
    STROKE, 2018, 49 (01) : 62 - +
  • [48] Predictive Capacity of Beat-to-Beat Blood Pressure Variability for Cardioautonomic and Vascular Dysfunction in Early Metabolic Challenge
    Fares, Souha A.
    Bakkar, Nour-Mounira Z.
    El-Yazbi, Ahmed F.
    FRONTIERS IN PHARMACOLOGY, 2022, 13
  • [49] Standing beat-to-beat blood pressure variability is reduced among fallers in the Malaysian Elders Longitudinal Study
    Goh, Choon-Hian
    Ng, Siew-Cheok
    Kamaruzzaman, Shahrul Bahyah
    Chin, Ai-Vyrn
    Tan, Maw Pin
    MEDICINE, 2017, 96 (42)
  • [50] BePCon: A Photoplethysmography-Based Quality-Aware Continuous Beat-to-Beat Blood Pressure Measurement Technique Using Deep Learning
    Roy, Monalisa Singha
    Gupta, Rajarshi
    Das Sharma, Kaushik
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71