Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement

被引:29
作者
Hoshide, Satoshi [1 ]
Yoshihisa, Akiomi [2 ,3 ]
Tsuchida, Fumihiro [4 ]
Mizuno, Hiroyuki [1 ]
Teragawa, Hiroki [5 ]
Kasai, Takatoshi [6 ]
Koito, Hitoshi [7 ]
Ando, Shin-ichi [8 ]
Watanabe, Yoshihiko [9 ]
Takeishi, Yasuchika [2 ]
Kario, Kazuomi [1 ]
机构
[1] Jichi Med Univ, Div Cardiovasc Med, Sch Med, Shimotsuke, Tochigi, Japan
[2] Fukushima Med Univ, Dept Cardiovasc Med, Fukushima, Japan
[3] Fukushima Med Univ, Dept Clin Lab Sci, Sch Hlth Sicence, Fukushima, Japan
[4] Yabuki Hosp, Dept Pulm Med, Yamagata, Japan
[5] JR Hiroshima Hosp, Dept Cardiovasc Med, Hiroshima, Japan
[6] Juntendo Univ, Dept Cardiovasc Med, Cardiovasc Resp Sleep Med, Grad Sch Med, Tokyo, Japan
[7] Misugikai Otokoyama Hosp, Dept Internal Med, Kyoto, Japan
[8] Kyushu Univ Hosp, Sleep Apnea Ctr, Fukuoka, Japan
[9] Nippon Dent Univ Hosp, Dept Internal Med, Tokyo, Japan
关键词
Pulse transit time; Beat-to-beat; Blood pressure variability; Continuous blood pressure monitoring; SLEEP; VARIABILITY; APNEA; HYPERTENSION; ANESTHESIA; MANAGEMENT; SEVERITY;
D O I
10.1038/s41440-022-00899-z
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Pulse transit time (PTT), which refers to the travel time between two arterial sites within the same cardiac cycle, has been developed as a novel cuffless form of continuous blood pressure (BP) monitoring. The aim of this study was to investigate differences in BP parameters, including BP variability, between those assessed by beat-to-beat PTT-estimated BP (eBP(BTB)) and those assessed by intermittent PTT-estimated BP at fixed time intervals (eBP(INT)) in patients suspected of having sleep disordered breathing (SDB). In 330 patients with SDB (average age, 66.8 +/- 11.9 years; 3% oxygen desaturation index [ODI], 21.0 +/- 15.0/h) from 8 institutes, PTT-estimated BP was continuously recorded during the nighttime. The average systolic eBP(BTB), maximum systolic and diastolic eBP(BTB), standard deviation (SD) of systolic and diastolic eBP(BTB), and coefficient variation (CV) of systolic and diastolic eBP(BTB) were higher than the respective values of eBP(INT) (all P < 0.05). Bland-Altman analysis showed a close agreement between eBP(BTB) and eBP(INT) in average systolic BP and SD and CV of systolic BP, while there were disagreements in both minimum and maximum values of eBP(BTB) and eBP(INT) in patients with high systolic BP (P < 0.05). Although systolic BP variability incrementally increased according to the tertiles of 3%ODI in both eBP(BTB) and eBP(INT) (all P < 0.05), there was no difference in this tendency between eBP(BTB) and eBP(INT). In patients with suspected SDB, the difference between e eBP(BTB) and eBP(INT) was minimal, and there were disagreements regarding both the minimum and maximum BP. However, there were agreements in regard to the index of BP variability between eBP(BTB) and eBP(INT).
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [31] The CNAP™ Finger Cuff for Noninvasive Beat-To-Beat Monitoring of Arterial Blood Pressure: An Evaluation in Intensive Care Unit Patients and a Comparison with 2 Intermittent Devices
    Lakhal, Karim
    Martin, Maelle
    Faiz, Sofian
    Ehrmann, Stephan
    Blanloeil, Yvonnick
    Asehnoune, Karim
    Rozec, Bertrand
    Boulain, Thierry
    ANESTHESIA AND ANALGESIA, 2016, 123 (05) : 1126 - 1135
  • [32] The physiologic complexity of beat-to-beat blood pressure is associated with age-related alterations in blood pressure regulation
    Jiang, Xin
    Mang, Xiaoying
    Zhou, Huiting
    Chen, Jingmei
    Tan, Huiying
    Ren, Huixia
    Huang, Baofeng
    Zhong, Lilian
    Lipsitz, Lewis A.
    Manor, Brad
    Guo, Yi
    Zhou, Junhong
    AGING CELL, 2024, 23 (01)
  • [33] The physiologic complexity of beat-to-beat blood pressure is associated with age-related alterations in blood pressure regulation
    Jiang, Xin
    Mang, Xiaoying
    Zhou, Huiting
    Chen, Jingmei
    Tan, Huiying
    Ren, Huixia
    Huang, Baofeng
    Zhong, Lilian
    Lipsitz, Lewis A.
    Manor, Brad
    Guo, Yi
    Zhou, Junhong
    AGING CELL, 2023,
  • [34] Beat-to-beat blood pressure variability, hippocampal atrophy, and memory impairment in older adults
    Lohman, Trevor
    Sible, Isabel
    Engstrom, Allison C.
    Kapoor, Arunima
    Shenasa, Fatemah
    Head, Elizabeth
    Sordo, Lorena
    Alitin, John Paul M.
    Gaubert, Aimee
    Nguyen, Amy
    Rodgers, Kathleen E.
    Bradford, David
    Nation, Daniel A.
    GEROSCIENCE, 2024, : 993 - 1003
  • [35] Blood Pressure Complexity Discriminates Pathological Beat-to-Beat Variability as a Marker of Vascular Aging
    Lee, Yun-Kai
    Mazzucco, Sara
    Rothwell, Peter M.
    Payne, Stephen J.
    Webb, Alastair J. S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (03):
  • [36] The Multiscale Dynamics of Beat-to-Beat Blood Pressure Fluctuation Links to Functions in Older Adults
    Jiang, Xin
    Cai, Yurun
    Wu, Xiaoyan
    Huang, Baofeng
    Chen, Yurong
    Zhong, Lilian
    Gao, Xia
    Guo, Yi
    Zhou, Junhong
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [37] High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm
    Olbers, Joakim
    Gille, Adam
    Ljungman, Petter
    Rosenqvist, Marten
    Ostergren, Jan
    Witt, Nils
    BLOOD PRESSURE, 2018, 27 (05) : 249 - 255
  • [38] Reliability of orthostatic beat-to-beat blood pressure tests: implications for population and clinical studies
    Finucane, C.
    Savva, G. M.
    Kenny, R. A.
    CLINICAL AUTONOMIC RESEARCH, 2017, 27 (01) : 31 - 39
  • [39] Correlation between beat-to-beat blood pressure variability and arterial stiffness in healthy adults in the cold pressor test
    Xu, Lin
    Lei, Hongqiang
    Qiu, Jian
    Ma, Jun
    Zhao, Hui
    Deng, Yu
    Lin, Wan-Hua
    Huang, Wenhua
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 977 - 985
  • [40] Positive airway pressure improves nocturnal beat-to-beat blood pressure surges in obesity hypoventilation syndrome with obstructive sleep apnea
    Carter, Jason R.
    Fonkoue, Ida T.
    Grimaldi, Daniela
    Emami, Leila
    Gozal, David
    Sullivan, Colin E.
    Mokhlesi, Babak
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2016, 310 (07) : R602 - R611