Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement

被引:29
|
作者
Hoshide, Satoshi [1 ]
Yoshihisa, Akiomi [2 ,3 ]
Tsuchida, Fumihiro [4 ]
Mizuno, Hiroyuki [1 ]
Teragawa, Hiroki [5 ]
Kasai, Takatoshi [6 ]
Koito, Hitoshi [7 ]
Ando, Shin-ichi [8 ]
Watanabe, Yoshihiko [9 ]
Takeishi, Yasuchika [2 ]
Kario, Kazuomi [1 ]
机构
[1] Jichi Med Univ, Div Cardiovasc Med, Sch Med, Shimotsuke, Tochigi, Japan
[2] Fukushima Med Univ, Dept Cardiovasc Med, Fukushima, Japan
[3] Fukushima Med Univ, Dept Clin Lab Sci, Sch Hlth Sicence, Fukushima, Japan
[4] Yabuki Hosp, Dept Pulm Med, Yamagata, Japan
[5] JR Hiroshima Hosp, Dept Cardiovasc Med, Hiroshima, Japan
[6] Juntendo Univ, Dept Cardiovasc Med, Cardiovasc Resp Sleep Med, Grad Sch Med, Tokyo, Japan
[7] Misugikai Otokoyama Hosp, Dept Internal Med, Kyoto, Japan
[8] Kyushu Univ Hosp, Sleep Apnea Ctr, Fukuoka, Japan
[9] Nippon Dent Univ Hosp, Dept Internal Med, Tokyo, Japan
关键词
Pulse transit time; Beat-to-beat; Blood pressure variability; Continuous blood pressure monitoring; SLEEP; VARIABILITY; APNEA; HYPERTENSION; ANESTHESIA; MANAGEMENT; SEVERITY;
D O I
10.1038/s41440-022-00899-z
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Pulse transit time (PTT), which refers to the travel time between two arterial sites within the same cardiac cycle, has been developed as a novel cuffless form of continuous blood pressure (BP) monitoring. The aim of this study was to investigate differences in BP parameters, including BP variability, between those assessed by beat-to-beat PTT-estimated BP (eBP(BTB)) and those assessed by intermittent PTT-estimated BP at fixed time intervals (eBP(INT)) in patients suspected of having sleep disordered breathing (SDB). In 330 patients with SDB (average age, 66.8 +/- 11.9 years; 3% oxygen desaturation index [ODI], 21.0 +/- 15.0/h) from 8 institutes, PTT-estimated BP was continuously recorded during the nighttime. The average systolic eBP(BTB), maximum systolic and diastolic eBP(BTB), standard deviation (SD) of systolic and diastolic eBP(BTB), and coefficient variation (CV) of systolic and diastolic eBP(BTB) were higher than the respective values of eBP(INT) (all P < 0.05). Bland-Altman analysis showed a close agreement between eBP(BTB) and eBP(INT) in average systolic BP and SD and CV of systolic BP, while there were disagreements in both minimum and maximum values of eBP(BTB) and eBP(INT) in patients with high systolic BP (P < 0.05). Although systolic BP variability incrementally increased according to the tertiles of 3%ODI in both eBP(BTB) and eBP(INT) (all P < 0.05), there was no difference in this tendency between eBP(BTB) and eBP(INT). In patients with suspected SDB, the difference between e eBP(BTB) and eBP(INT) was minimal, and there were disagreements regarding both the minimum and maximum BP. However, there were agreements in regard to the index of BP variability between eBP(BTB) and eBP(INT).
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [21] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Arash Abiri
    En-Fan Chou
    Weining Shen
    Mark J. Fisher
    Michelle Khine
    Scientific Reports, 13
  • [22] ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING
    Estrada, Sebastian
    Kwon, Younghoon
    Baruch, Martin
    Harrison, Elizabeth
    Williams, Ronald
    Cho, Yeilim
    Gerdt, David
    Bonner, Heather
    Mazimba, Sula
    Berry, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1893 - 1893
  • [23] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Abiri, Arash
    Chou, En-Fan
    Shen, Weining
    Fisher, Mark J.
    Khine, Michelle
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [24] Estimation of beat-to-beat systolic blood pressure using pulse arrive time and pulse width derived from the photoplethysmogram
    Lin, YH
    Ko, PCI
    Wang, HY
    Lu, TC
    Chen, YY
    Jan, IC
    Jan, GJ
    Chou, NK
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3456 - 3458
  • [25] Correction: Can pulse transit time-estimated blood pressure become a savior for blood pressure research?
    Mitsuru Ohishi
    Hypertension Research, 2023, 46 (4) : 1069 - 1069
  • [26] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [27] Baroreflex failure and beat-to-beat blood pressure variation
    Kishi, Takuya
    HYPERTENSION RESEARCH, 2018, 41 (08) : 547 - 552
  • [28] Beat-to-Beat Cardiac Pulse Rate Measurement From Video
    Hill, Brian L.
    Liu, Xin
    McDuff, Daniel
    2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW 2021), 2021, : 2739 - 2742
  • [29] Baroreflex failure and beat-to-beat blood pressure variation
    Takuya Kishi
    Hypertension Research, 2018, 41 : 547 - 552
  • [30] Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data
    Lin, Yu-Ting
    Lo, Yu-Lun
    Lin, Chen-Yun
    Frasch, Martin G.
    Wu, Hau-Tieng
    PLOS ONE, 2019, 14 (09):