Retinal Vessels Segmentation Based on Dilated Multi-Scale Convolutional Neural Network

被引:77
作者
Jiang, Yun [1 ]
Tan, Ning [1 ]
Peng, Tingting [1 ]
Zhang, Hai [1 ]
机构
[1] Northwest Normal Univ, Coll Comp Sci & Engn, Lanzhou, Gansu, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi-scale; retinal vessel segmentation; deep convolutional neural network; dilation convolutions; residual module; BLOOD-VESSELS; IMAGES; MODEL;
D O I
10.1109/ACCESS.2019.2922365
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Accurate segmentation of retinal vessels is a basic step in diabetic retinopathy (DR) detection. Most methods based on deep convolutional neural network (DCNN) have small receptive fields, and hence they are unable to capture global context information of larger regions, with difficult to identify pathological. The final segmented retina vessels contain more noise with low classification accuracy. Therefore, in this paper, we propose a DCNN structure named as D-Net. In the encoding phase, we reduced the loss of feature information by reducing the downsampling factor, which reduced the difficulty of tiny thin vessels segmentation. We use the combined dilated convolution to effectively enlarge the receptive field of the network and alleviate the "grid problem" that exists in the standard dilated convolution. In the proposed multi-scale information fusion module (MSIF), parallel convolution layers with different dilation rates are used, so that the model can obtain more dense feature information and better capture retinal vessel information of different sizes. In the decoding module, the skip layer connection is used to propagate context information to higher resolution layers, so as to prevent low-level information from passing the entire network structure. Finally, our method was verified on DRIVE, STARE, and CHASE dataset. The experimental results show that our network structure outperforms some state-of-art method, such as N-4-fields, U-Net, and DRIU in terms of accuracy, sensitivity, specificity, and AUC(ROC). Particularly, D-Net outperforms U-Net by 1.04 %, 1.23 %, and 2.79 % in DRIVE, STARE, and CHASE dataset, respectively.
引用
收藏
页码:76342 / 76352
页数:11
相关论文
共 42 条
[1]  
Abadi M., 2015, TENSORFLOW LARGE SCA, DOI DOI 10.48550/ARXIV.1603.04467
[2]   Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy [J].
Abramoff, Michael D. ;
Folk, James C. ;
Han, Dennis P. ;
Walker, Jonathan D. ;
Williams, David F. ;
Russell, Stephen R. ;
Massin, Pascale ;
Cochener, Beatrice ;
Gain, Philippe ;
Tang, Li ;
Lamard, Mathieu ;
Moga, Daniela C. ;
Quellec, Gwenole ;
Niemeijer, Meindert .
JAMA OPHTHALMOLOGY, 2013, 131 (03) :351-357
[3]  
[Anonymous], 2017, ARXIV170404861
[4]  
[Anonymous], 2018, ARXIV180404206
[5]  
[Anonymous], 2015, VIPIMAGE
[6]  
Aramesh R., 2014, INT J ADV STUD COMPU, V3, P1
[7]   Trainable COSFIRE filters for vessel delineation with application to retinal images [J].
Azzopardi, George ;
Strisciuglio, Nicola ;
Vento, Mario ;
Petkov, Nicolai .
MEDICAL IMAGE ANALYSIS, 2015, 19 (01) :46-57
[8]   DeepLab: Semantic Image Segmentation with Deep Convolutional Nets, Atrous Convolution, and Fully Connected CRFs [J].
Chen, Liang-Chieh ;
Papandreou, George ;
Kokkinos, Iasonas ;
Murphy, Kevin ;
Yuille, Alan L. .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2018, 40 (04) :834-848
[9]  
Dasgupta A, 2017, I S BIOMED IMAGING, P248, DOI 10.1109/ISBI.2017.7950512
[10]   Wavelet-Based Energy Features for Glaucomatous Image Classification [J].
Dua, Sumeet ;
Acharya, U. Rajendra ;
Chowriappa, Pradeep ;
Sree, S. Vinitha .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (01) :80-87