Preparation and evaluation of highly hydrophilic aptamer-based hybrid affinity monolith for on-column specific discrimination of ochratoxin A

被引:36
作者
Chen, Yiqiong [1 ]
Ding, Xinyue [1 ]
Zhu, Dandan [1 ]
Lin, Xucong [1 ]
Xie, Zenghong [1 ]
机构
[1] Fuzhou Univ, Inst Food Safety & Environm Monitoring, Fuzhou 350108, Fujian, Peoples R China
关键词
Hydrophilic; Aptamer; Hybrid affinity monolith; Specific discrimination; Ochratoxin A; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYHEDRAL OLIGOMERIC SILSESQUIOXANES; RING-OPENING POLYMERIZATION; SOLID-PHASE EXTRACTION; CAPILLARY ELECTROCHROMATOGRAPHY; MIXED-MODE; SELECTIVE RECOGNITION; HPLC-FLD; POLYETHYLENIMINE; QUANTIFICATION;
D O I
10.1016/j.talanta.2019.03.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nonspecific adsorption is a challenge of specific recognition on aptamer-based affinity monoliths. Here, a novel highly hydrophilic polyhedral oligomeric silsesquioxane (POSS)-containing aptamer-based hybrid-silica affinity monolith with a good recognition nature was prepared and used for specific discrimination of ochratoxin A (OTA). A homogeneous polymerization mixture consisted of POSS chemicals, hydrophilic monomers and aptamer solution was directly polymerized via the "one-pot" method. Preparation and characterization of the resultant affinity monolith were studied in detail. A highly hydrophilic nature was obtained and the typical hydrophilic interaction liquid chromatography (HILIC) was observed when acetonitrile (ACN) content in mobile phase was 25%, which reached the highest hydrophilicity of POSS-based hybrid monoliths. By using OTA as model analyte, the nonspecific adsorption was effectively suppressed. The recovery of the analogue ochratoxin B (OTB) was only about 0.1% even if the content of OTB was 50 times more than OTA, which was much better than other POSS-containing monoliths and polar siloxane-based hybrid monoliths. Applied to beer samples, the adsorption of background materials was drastically resisted, and efficient recognition of OTA was obtained with the recoveries of 94.9-99.8%. Much less disturbance was observed than that occurred in hydrophobic POSS-based affinity monolith. It lights an attractive implement with high hydrophilicity and specificity for online selective recognition of OTA.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 41 条
  • [1] Miniaturized DNA aptamer-based monolithic sorbent for selective extraction of a target analyte coupled on-line to nanoLC
    Brothier, Fabien
    Pichon, Valerie
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (30) : 7875 - 7886
  • [2] Aptamer-based polyhedral oligomeric silsesquioxane (POSS)-containing hybrid affinity monolith prepared via a "one-pot" process for selective extraction of ochratoxin A
    Chen, Yiqiong
    Chen, Maolin
    Chi, Jinxin
    Yu, Xia
    Chen, Yongxuan
    Lin, Xucong
    Xie, Zenghong
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1563 : 37 - 46
  • [3] Aptamer functionalized hydrophilic polymer monolith with gold nanoparticles modification for the sensitive detection of human α-thrombin
    Chen, Yuanbo
    Deng, Nan
    Wu, Ci
    Liang, Yu
    Jiang, Bo
    Yang, Kaiguang
    Liang, Zhen
    Zhang, Lihua
    Zhang, Yukui
    [J]. TALANTA, 2016, 154 : 555 - 559
  • [4] A facile AuNPs@aptamer-modified mercaptosiloxane-based hybrid affinity monolith with an unusually high coverage density of aptamer for on-column selective extraction of ochratoxin A
    Chi, Jinxin
    Chen, Maolin
    Deng, Lijun
    Lin, Xucong
    Xie, Zenghong
    [J]. ANALYST, 2018, 143 (21) : 5210 - 5217
  • [5] A review on the occurrence and control of ochratoxigenic fungal species and ochratoxin A in dehydrated grapes, non-fortified dessert wines and dried vine fruit in the Mediterranean area
    Covarelli, L.
    Beccari, G.
    Marini, A.
    Tosi, L.
    [J]. FOOD CONTROL, 2012, 26 (02) : 347 - 356
  • [6] Determination of Ochratoxin A with a DNA Aptamer
    Cruz-Aguado, Jorge A.
    Penner, Gregory
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (22) : 10456 - 10461
  • [7] Aptamer Modified Organic-Inorganic Hybrid Silica Monolithic Capillary Columns for Highly Selective Recognition of Thrombin
    Deng, Nan
    Liang, Zhen
    Liang, Yu
    Sui, Zhigang
    Zhang, Liyuan
    Wu, Qi
    Yang, Kaiguang
    Zhang, Lihua
    Zhang, Yukui
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (23) : 10186 - 10190
  • [8] A review: Aptamer-based analytical strategies using the nanomaterials for environmental and human monitoring of toxic heavy metals
    Farzin, Leila
    Shamsipur, Mojtaba
    Sheibani, Shahab
    [J]. TALANTA, 2017, 174 : 619 - 627
  • [9] Gnanasekaran D, 2009, J SCI IND RES INDIA, V68, P437
  • [10] Approach for ochratoxin A fast screening in spices using clean-up tandem immunoassay columns with confirmation by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS)
    Goryacheva, I. Yu.
    De Saeger, S.
    Lobeau, M.
    Eremin, S. A.
    Barna-Vetro, I.
    Van Peteghem, C.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 38 - 45