A fast model to identify multiple indoor contaminant sources with known releasing time by considering real sensor characteristics

被引:0
作者
Cai, Hao [1 ]
Kong, Lingjuan [2 ]
Cai, Hao [1 ]
Li, Xianting [3 ]
Shao, Xiaoliang [3 ]
机构
[1] Corps PLA Univ Sci & Technol, Engn Inst Engn Corps, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Artillery Acad, Nanjing, Jiangsu, Peoples R China
[3] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
来源
2013 INTERNATIONAL CONFERENCE ON MATERIALS FOR RENEWABLE ENERGY AND ENVIRONMENT (ICMREE), VOLS 1-3 | 2013年
关键词
source identification; contaminant source; indoor environment; Computational fluid dynamics; Sensor; IDENTIFICATION; BUILDINGS; LOCATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A theoretical model was presented for quickly identifying multiple indoor constant contaminant sources with known releasing time by considering the sensor thresholds and measurement errors. The model was numerically demonstrated and validated by case studies. The results indicated that the model can potentially be effective with high sensor thresholds and measurement errors. This study will contribute to developing source identification techniques using real sensors.
引用
收藏
页码:630 / 634
页数:5
相关论文
共 13 条
[1]  
Anderson John David, 1995, Computational Fluid Dynamics, V206
[2]   Multizone airflow Modeling in buildings: History and theory [J].
Axley, James .
HVAC&R RESEARCH, 2007, 13 (06) :907-928
[3]  
Cai H., 2011, 12 INT IBPSA C BUILD, P672
[4]  
Chen GY, 1998, ENERG BUILDINGS, V28, P137
[5]   Location identification for indoor instantaneous point contaminant source by probability-based inverse Computational Fluid Dynamics modeling [J].
Liu, X. ;
Zhai, Z. .
INDOOR AIR, 2008, 18 (01) :2-11
[6]   Prompt tracking of indoor airborne contaminant source location with probability-based inverse multi-zone modeling [J].
Liu, Xiang ;
Zhai, Zhiqiang John .
BUILDING AND ENVIRONMENT, 2009, 44 (06) :1135-1143
[7]   An analytical expression for transient distribution of passive contaminant under steady flow field [J].
Ma, Xiaojun ;
Shao, Xiaoliang ;
Li, Xianting ;
Lin, Yiwei .
BUILDING AND ENVIRONMENT, 2012, 52 :98-106
[8]  
Musser A., 2001, ASHRAE Transactions, V107, P371
[9]   Rapidly locating and characterizing pollutant releases in buildings [J].
Sohn, MD ;
Reynolds, P ;
Singh, N ;
Gadgil, AJ .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2002, 52 (12) :1422-1432
[10]   Evaluation of some assumptions used in multizone airflow network models [J].
Wang, Liangzhu ;
Chen, Qingyan .
BUILDING AND ENVIRONMENT, 2008, 43 (10) :1671-1677