Buccal cortical bone thickness for mini-implant placement

被引:152
作者
Baumgaertel, Sebastian [1 ]
Hans, Mark G. [1 ]
机构
[1] Case Western Reserve Univ, Sch Dent Med, Dept Orthodont, Cleveland, OH 44106 USA
关键词
OPEN-BITE; ANCHORAGE; MAXILLARY; PALATE; TEETH;
D O I
10.1016/j.ajodo.2007.10.045
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The thickness of cortical bone is an important factor in mini-implant stability. In this study, we investigated the buccal cortical bone thickness of every interdental area as an aid in planning mini-implant placement. Methods: From the cone-beam computed tomography scans of 30 dry skulls, 2-dimensional slices through every interdental area were generated. On these, cortical bone thickness was measured at 2, 4, and 6 mm from the alveolar crest. Intraclass correlation was used to determine intrarater reliability, and analysis of variance (ANOVA) was used to test for differences in cortical bone thickness. Results: Buccal cortical bone thickness was greater in the mandible than in the maxilla. Whereas this thickness increased with increasing distance from the alveolar crest in the mandible and in the maxillary anterior sextant, it behaved differently in the maxillary buccal sextants; it was thinnest at the 4-mm level. Conclusions: Interdental buccal cortical bone thicknes varies in the jaws. There appears to be a distinct pattern. Knowledge of this pattern and the mean values for thickness can aid in mini-implant site selection and preparation. (Am J Orthod Dentofacial Orthop 2009;136:230-5)
引用
收藏
页码:230 / 235
页数:6
相关论文
共 26 条
[1]   Mini-implant anchorage for the orthodontic practitioner [J].
Baumgaertel, Sebastian ;
Razavi, Mohammad R. ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (04) :621-627
[2]   Systematic review of the experimental use of temporary skeletal anchorage devices in orthodontics [J].
Cornelis, Marie A. ;
Scheffler, Nicole R. ;
De Clerck, Hugo J. ;
Tulloch, J. F. Camilla ;
Nyssen-Behets, Catherine .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) :S52-S58
[3]  
FRIBERG B, CLIN ORAL IMPLANTS R, V6, P213
[4]  
Henriksen B, 2003, INT J ORAL MAX IMPL, V18, P578
[5]  
Holmes D C, 1997, J Oral Implantol, V23, P104
[6]   Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: Pilot study [J].
Homolka, P ;
Beer, A ;
Birkfellner, W ;
Nowotny, R ;
Gahleitner, A ;
Tschabitscher, M ;
Bergmann, H .
RADIOLOGY, 2002, 224 (01) :247-252
[7]   Bone thickness of the palate for orthodontic mini-implant anchorage in adults [J].
Kang, Sungmin ;
Lee, Shin-Jae ;
Ahn, Sug-Joon ;
Heo, Min-Suk ;
Kim, Tae-Woo .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) :S74-S81
[8]  
Kanomi R, 1997, J Clin Orthod, V31, P763
[9]   Soft-tissue and cortical-bone thickness at orthodontic implant sites [J].
Kim, Hee-Jin ;
Yun, Hee-Sun ;
Park, Hyun-Do ;
Kim, Doo-Hyung ;
Park, Young-Chel .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (02) :177-182
[10]   Risks and complications of orthodontic miniscrews [J].
Kravitz, Neal D. ;
Kusnoto, Budi .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) :S43-S51