Brain micromotion around implants in the rodent somatosensory cortex

被引:230
作者
Gilletti, Aaron [1 ]
Muthuswamy, Jit [1 ]
机构
[1] Arizona State Univ, Harrington Dept Bioengn, Tempe, AZ 85287 USA
关键词
D O I
10.1088/1741-2560/3/3/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The magnitude of brain tissue micromotion relative to stationary brain implants and its impact on the viability and function of the surrounding brain tissue due to mechanical stresses is poorly understood. The central goal of this study is to characterize surface micromotion in the somatosensory cortex against stationary cylindrical implants. We used a differential variable reluctance transducer (DVRT) in adult rats (n = 6) to monitor micromotion normal to the somatosensory cortex surface. Experiments were performed both in the presence and in the absence of dura mater and displacement measurements were made at three different locations within craniotomies of two different sizes. In anesthetized rats, pulsatile surface micromotion was observed to be in the order of 10-30 mu m due to pressure changes during respiration and 2-4 mu m due to vascular pulsatility. Brain displacement values due to respiration were significantly lower in the presence of the dura compared to those without the dura. In addition, large inward displacements of brain tissue between 10-60 mu m were observed in n = 3 animals immediately following the administration of anesthesia. Such significant micromotion can impact a wide variety of acute and chronic procedures involving any brain implants, precise neurosurgery or imaging and therefore has to be factored in the design of such procedures.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 39 条
[1]   PERIODIC COMPONENTS IN STEADY-STATE ACTIVITY OF CUNEATE NEURONS AND THEIR POSSIBLE ROLE IN SENSORY CODING [J].
AMASSIAN, VE ;
GIBLIN, D .
JOURNAL OF PHYSIOLOGY-LONDON, 1974, 243 (02) :353-385
[2]  
[Anonymous], 1990, NEURAL PROSTHESES FU
[3]  
[Anonymous], 1984, Pathologic basis of disease
[4]   SYNAPTIC EVENTS AND DISCHARGE PATTERNS OF COCHLEAR NUCLEUS CELLS .2. FREQUENCY-MODULATED TONES [J].
BRITT, R ;
STARR, A .
JOURNAL OF NEUROPHYSIOLOGY, 1976, 39 (01) :179-194
[5]   QUANTITATIVE-ANALYSIS OF METHODS FOR REDUCING PHYSIOLOGICAL BRAIN PULSATIONS [J].
BRITT, RH ;
ROSSI, GT .
JOURNAL OF NEUROSCIENCE METHODS, 1982, 6 (03) :219-229
[6]   INTRACELLULAR STUDY OF SYNAPTIC EVENTS RELATED TO PHASE-LOCKING RESPONSES OF CAT COCHLEAR NUCLEUS CELLS TO LOW-FREQUENCY TONES [J].
BRITT, RH .
BRAIN RESEARCH, 1976, 112 (02) :313-327
[7]   WEIGHTLESS MICRO-ELECTRODES FOR RECORDING EXTRACELLULAR UNIT ACTION POTENTIALS FROM THE CENTRAL NERVOUS SYSTEM [J].
BURNS, BD ;
ROBSON, JG .
NATURE, 1960, 186 (4720) :246-247
[8]   Fibre optic confocal imaging (FOCI) of keratinocytes, blood vessels and nerves in hairless mouse skin in vivo [J].
Bussau, LJ ;
Vo, LT ;
Delaney, PM ;
Papworth, GD ;
Barkla, DH ;
King, RG .
JOURNAL OF ANATOMY, 1998, 192 :187-194
[9]   A framework for predictive modeling of anatomical deformations [J].
Davatzikos, C ;
Shen, DG ;
Mohamed, A ;
Kyriacou, SK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) :836-843
[10]   CHAMBER FOR MICROELECTRODE STUDIES IN THE CEREBRAL CORTEX [J].
DAVIES, PW .
SCIENCE, 1956, 124 (3213) :179-180