Design of a ridge filter structure based on the analysis of dose distributions

被引:2
作者
Fujimoto, Rintaro [1 ]
Takayanagi, Taisuke [1 ]
Fujitaka, Shinichiro [1 ]
机构
[1] Hitachi Ltd, Energy & Environm Syst Lab, Hitachi, Ibaraki, Japan
关键词
HEAVY-ION THERAPY; MONTE-CARLO CODE; RIPPLE FILTER; PARTICLE; SYSTEM;
D O I
10.1088/0031-9155/54/13/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dose distributions distorted by a periodic structure, such as a ridge filter, are analytically investigated. Based on the beam optics, the fluence distributions of scanned beams passing through the ridge filter are traced. It is shown that the periodic lateral dose distribution blurred by multiple Coulomb scattering can be expressed by a sum of cosine functions through Fourier transform. The result shows that the dose homogeneity decreases exponentially as the period of the structure becomes longer. This analysis is applied to the example case of a mini-ridge filter. Themini-ridge filter is designed to broaden sharp Bragg peaks for an energy-stacking irradiation method. The dose distributions depend on the period of the ridge filter structure and the angular straggling at the ridge filter position. Several cases are prepared where the period and angular straggling are supposed to be probable values. In these cases, the lateral distributions obtained by the analytical method are compared to Monte Carlo simulation results. Both distributions show good agreement with each other within 1%, which means that this analysis allows estimation of the dose distribution downstream of the ridge filter quantitatively. The appropriate period of grooves and scatterer width can be determined which ensures sufficient homogeneity.
引用
收藏
页码:N273 / N282
页数:10
相关论文
共 11 条
[1]   Ridge filter design for proton therapy at Hyogo Ion Beam Medical Center [J].
Akagi, T ;
Higashi, A ;
Tsugami, H ;
Sakamoto, H ;
Masuda, Y ;
Hishikawa, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (22) :N301-N312
[2]   MOLIERE THEORY OF MULTIPLE SCATTERING [J].
BETHE, HA .
PHYSICAL REVIEW, 1953, 89 (06) :1256-1266
[3]   What is the optimum leaf width of a multileaf collimator? [J].
Bortfeld, T ;
Oelfke, U ;
Nill, S .
MEDICAL PHYSICS, 2000, 27 (11) :2494-2502
[4]   MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :296-305
[5]   Development of general-purpose particle and heavy ion transport Monte Carlo code [J].
Iwase, H ;
Niita, K ;
Nakamura, T .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2002, 39 (11) :1142-1151
[6]   PHITS - a particle and heavy ion transport code system [J].
Niita, Koji ;
Sato, Tatsuhiko ;
Iwase, Hiroshi ;
Nose, Hiroyuki ;
Nakashima, Hiroshi ;
Sihver, Lembit .
RADIATION MEASUREMENTS, 2006, 41 (9-10) :1080-1090
[7]   Improvement of three-dimensional Monte Carlo code PHITS for heavy ion therapy [J].
Nose, H ;
Niita, K ;
Hara, M ;
Uematsu, K ;
Azuma, O ;
Miyauchi, Y ;
Komori, M ;
Kanai, T .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2005, 42 (02) :250-255
[8]   Ridge filter design and optimization for the broad-beam three-dimensional irradiation system for heavy-ion radiotherapy [J].
Schaffner, B ;
Kanai, T ;
Futami, Y ;
Shimbo, M ;
Urakabe, E .
MEDICAL PHYSICS, 2000, 27 (04) :716-724
[9]   COMMUNICATION IN THE PRESENCE OF NOISE [J].
SHANNON, CE .
PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1949, 37 (01) :10-21
[10]   A miniature ripple filter for filtering a ripple found in the distal part of a proton SOBP [J].
Takada, Y ;
Kobayashi, Y ;
Yasuoka, K ;
Terunuma, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 524 (1-3) :366-373