Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler

被引:97
作者
Russell, D [1 ]
Brucher, R
机构
[1] Natl Hosp Norway, Dept Neurol, N-0027 Oslo, Norway
[2] Univ Appl Sci, Dept Med Engn, Ulm, Germany
关键词
carotid stenosis; cerebral embolism; mechanical heart valve protheses; ultrasonography; Doppler;
D O I
10.1161/01.STR.0000022809.46400.4B
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. Methods-The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli is based on the principle that solid microemboli reflect more ultrasound at the higher than at the lower frequency, whereas the opposite is the case for gaseous microemboli. In the in vitro studies, 159 plastic spheres (50 or 80 [mum in diameter) and 105 gas bubbles (8 to 25 mum) were studied in a pulsatile closed-loop system containing irodinium or pig blood. In vivo studies were carried out for 1 hour in 15 patients with mechanical heart valves and in 45 patients with carotid stenosis. This gave a total of 60 hours of online automatic monitoring in patients. Results-In the in vitro studies, 152 of the 159 (95.6%) plastic spheres were classified as solid, and 7 (4.4%) were classified as uncertain solid. Of the 105 gas bubbles, 99 (94.3%) were classified as gaseous and 6 (5.7%) as uncertain gaseous. Thus, correct classification was made for 251 (95.1%) of the 264 embolic events studied. A comparison between the automatic multifrequency discrimination and the known embolic classification gave a kappa value of 0.897 (P<0.0001). The multifrequency Doppler classified 433 (84.2%) of the 514 emboli detected in the mechanical heart valve patients as gaseous, 74 (14.4%) as solid, and 7 (1.4%) as uncertain (3 uncertain solid, 4 uncertain gas). Thirty-two emboli were detected in 17 (38%) of the 45 carotid stenosis patients; 30 (93.7%) were classified as solid and 2 (6.3%) as uncertain solid. Conclusions-This study has shown that multifrequency transcranial Doppler can be used to automatically differentiate between solid and gaseous microemboli online. Most detected microemboli in this initial study of mechanical heart valves were classified as gaseous, whereas most were classified as solid in the patients with carotid stenosis.
引用
收藏
页码:1975 / 1980
页数:6
相关论文
共 51 条
[1]   THE SIGNIFICANCE OF MICROEMBOLI DETECTION BY MEANS OF TRANSCRANIAL DOPPLER ULTRASONOGRAPHY MONITORING IN CAROTID ENDARTERECTOMY [J].
ACKERSTAFF, RGA ;
JANSEN, C ;
MOLL, FL ;
VERMEULEN, FEE ;
HAMERLIJNCK, RPHM ;
MAUSER, HW .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :963-969
[2]  
Altmann D., 1991, Practical Statistics for Medical Research
[3]   Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: a prospective study [J].
Bendszus, M ;
Koltzenburg, M ;
Burger, R ;
Warmuth-Metz, M ;
Hofmann, E ;
Solymosi, L .
LANCET, 1999, 354 (9190) :1594-1597
[4]   METHODOLOGICAL ISSUES IN THE ASSESSMENT OF NEUROPSYCHOLOGIC FUNCTION AFTER CARDIAC-SURGERY [J].
BLUMENTHAL, JA ;
MAHANNA, EP ;
MADDEN, DJ ;
WHITE, WD ;
CROUGHWELL, ND ;
NEWMAN, MF .
ANNALS OF THORACIC SURGERY, 1995, 59 (05) :1345-1350
[5]   Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization [J].
Braekken, SK ;
Endresen, K ;
Russell, D ;
Brucher, R ;
Kjekshus, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (05) :632-637
[6]  
BRAEKKEN SK, 1995, STROKE, V26, P1225
[7]  
Braekken SK, 1997, STROKE, V28, P1988
[8]   Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler [J].
Brucher, R ;
Russell, D .
STROKE, 2002, 33 (08) :1969-1974
[9]  
BRUCHER R, 1994, CEREBROVASC DIS, V4, P18
[10]  
BRUCHER R, 1997, NEW TRENDS CEREBRAL, P364