A new method of evaluation of X-ray pulsar detector sensitivity

被引:0
|
作者
Hu Hui-jun [1 ]
Song Juan [1 ]
Shao Si-pei [1 ]
Liu Jin-sheng [1 ]
Wang Wen-cong [1 ]
机构
[1] Shan Dong Inst Space Elect Technol, Yantai 264670, Peoples R China
来源
FIFTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION | 2019年 / 11023卷
关键词
X-ray pulsar navigation; contour accumulation; detecting sensitivity; signal-to-noise ratio;
D O I
10.1117/12.2521915
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Detection sensitivity is an important indicator of the X-ray pulsar detector. In order to achieve the accuratesensitivity of the detector, a new method of calculate detection sensitivity is proposed calculation. Combining with the characteristics of X-ray pulsar radiation spectrum and detector spectral,classic pulse accumulation model is corrected.A new signal to noise ratio (SNR) calculation formula is deduced by using the new pulse accumulation model. Constructing a new variable Z, which has close relationship with SNR. Through setting the SNR, the analysis and simulation verification for detection sensitivity and confidence level can be made. Simulation verification shows that the monte carlo simulation result is consistent with the theoretical results, and the maximum deviation is only 5%, which is far less than the deviation caused by the space environment disturbance.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Augmentation Method for X-Ray Pulsar Navigation Using Time Difference of Arrival and Range Measurement, Based on Polarization Encoded Pulse Position Modulation
    Jiao, Rong
    Zhang, Hua
    AEROSPACE, 2025, 12 (02)
  • [32] Simulation of X-Ray transmitted in the square polycapillary X-ray lens
    Peng, Shiqi
    Liu, Zhiguo
    Sun, Tianxi
    Wang, Kai
    Yi, Longtao
    Yang, Kui
    Chen, Man
    Wang, Jinbang
    SELECTED PAPERS OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE CONFERENCES HELD NOVEMBER 2015, 2016, 9796
  • [33] The Effect of Experiment Variabies on Industrial X-ray Micro-computed Tomography Sensitivity
    Roth, D. J.
    Rauser, R. W.
    MATERIALS EVALUATION, 2015, 73 (12) : 1577 - 1584
  • [34] Image quality in x-ray microtomography
    Davis, GR
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 213 - 221
  • [35] Aspects of X-ray microtomography equipment design
    Davis, GR
    Elliott, JC
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 182 - 190
  • [36] Physical evaluation of a new technique for X-ray dose reduction:: Measurement of signal-to-noise ratio and modulation transfer function in an animal model
    Paech, A.
    Schulz, A. P.
    Hahlbrauck, B.
    Kiene, J.
    Wenzl, M. E.
    Juergens, Ch.
    PHYSICA MEDICA, 2007, 23 (01) : 33 - 40
  • [37] Evaluating the index of panoramic X-ray image quality using K-means clustering method
    Imajo, Satoshi
    Tanabe, Yoshinori
    Nakamura, Nobue
    Honda, Mitsugi
    Kuroda, Masahiro
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [38] Signal-to-noise ratio analysis of X-ray grating interferometry with the reverse projection extraction method
    Wu, Z.
    Wang, Z. L.
    Gao, K.
    Wang, D. J.
    Wang, S. H.
    Chen, J.
    Chen, H.
    Zhang, K.
    Zhu, P. P.
    Wu, Z. Y.
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2014, 196 : 75 - 79
  • [39] Evaluating the index of panoramic X-ray image quality using K-means clustering method
    Satoshi Imajo
    Yoshinori Tanabe
    Nobue Nakamura
    Mitsugi Honda
    Masahiro Kuroda
    Egyptian Journal of Radiology and Nuclear Medicine, 55
  • [40] The influence of energy weighting on X-ray imaging quality
    Giersch, J
    Niederlöhner, D
    Anton, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 68 - 74