Effective bond length of FRP-to-concrete adhesively-bonded joints: Experimental evaluation of existing models

被引:113
作者
Hosseini, Ardalan [1 ]
Mostofinejad, Davood [1 ]
机构
[1] IUT, Dept Civil Engn, Esfahan 8415683111, Iran
关键词
Fiber reinforced polymer (FRP); Externally bonded reinforcement (EBR); Bond strength model; Effective bond length; Single-shear test; Particle image velocimetry (PIV); IMAGE VELOCIMETRY PIV; DEFORMATION MEASUREMENT; STRENGTH; STRESS; SHEETS; STEEL;
D O I
10.1016/j.ijadhadh.2013.09.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Bond behavior of adhesively-bonded fiber reinforced polymers (FRPs) to concrete substrate has been investigated by many researchers worldwide. An interesting aspect of FRP-to-concrete bond behavior is that there exists an effective bond length beyond which an extension of the bond length cannot increase the ultimate capacity of the joint. Effective bond length of FRP composites, in fact, is an important part of all strengthening calculations, and conservative design guideline predictions can lead to waste of composite materials in strengthening projects. Consequently, the main intention of the current study is to evaluate the accuracy of existing guideline models of effective bond length by means of single-shear bond tests. To do so, carbon FRP (CFRP) sheets with a wide range of bond length from 20 to 250 mm, were adhered to 22 concrete prisms using externally bonded reinforcement (EBR) technique. The specimens were then subjected to single-shear test and debonding loads as well as the effective bond length of the CFRP sheets were determined. Moreover, an image based technique, i.e. particle image velocimetry (PIV) was used to verify the estimated effective bond length by analyzing strain distribution along the CFRP strips during loading process. Experimental results of the current study show that fib Bulletin 14 model overestimates debonding loads and effective bond length. The model adopted by ACI 440.2R-08 also overestimates effective bond length while accurately predicts debonding loads. Appropriate calibration factors were introduced to modify the existing models for CFRP sheets. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 38 条
[1]  
ADRIAN RJ, 1991, ANNU REV FLUID MECH, V23, P261, DOI 10.1146/annurev.fluid.23.1.261
[2]   Experimental investigation and fracture analysis of debonding between concrete and FRP sheets [J].
Ali-Ahmad, Mohamad ;
Subramaniam, Kolluru ;
Ghosn, Michel .
JOURNAL OF ENGINEERING MECHANICS, 2006, 132 (09) :914-923
[3]  
[Anonymous], 2000, ASTM D3039/3039M-00: Standard Test Method for TensileProperties of Polymer Matrix Composite Materials
[4]  
[Anonymous], 2008, ACI 4402R 08
[5]  
ASTM, 2002, C19202 ASTM
[6]  
Blaschko M., 1998, Fiber Composites in Infrastructure, P315
[7]  
Chajes MJ, 1996, ACI STRUCT J, V93, P208
[8]   Anchorage strength models for FRP and steel plates bonded to concrete [J].
Chen, JF ;
Teng, JG .
JOURNAL OF STRUCTURAL ENGINEERING, 2001, 127 (07) :784-791
[9]   Development of the nonlinear bond stress-slip model of fiber reinforced plastics sheet-concrete interfaces with a simple method [J].
Dai, JG ;
Ueda, T ;
Sato, Y .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) :52-62
[10]  
Federation Internationale du Beton (FIB), 2001, B INF, V14